Olympus FV1000 manual Diffusion Measurement Package, RICS-Raster Imaging Correlation Spectroscopy

Page 16

1.5

1

130

0.5

125 Pixels

0

105

125105

130

Pixels

Diffusion Measurement Package

This optional software module enables data acquisition and analysis to investigate the molecular interaction and concentrations by calculating the diffusion coefficients of molecules within the cell.

Diverse analysis methods (RICS/ccRICS, point FCS/point FCCS and FRAP) cover a wide range of molecular sizes and speeds.

RICS—Raster Imaging Correlation Spectroscopy

Raster image correlation spectroscopy (RICS) is a new method for analyzing the diffusion and binding dynamics of molecules in an entire, single image. RICS uses a spatial correlation algorithm to calculate diffusion coefficients and the number of molecules in specified regions.

Cross correlation RICS (ccRICS) characterizes molecular interactions using fluorescent- labeled molecules in two colors.

point FCS—Point scan Fluorescence Correlation Spectroscopy

point scan fluorescence correlation spectroscopy (point FCS) analyzes intensity fluctuations caused by diffusion or binding/unbinding interactions of a protein complex. point FCS uses an auto correlation function to carry out operations on fluorescence signals obtained by continuous scanning of a single pixel on the screen.

point scan fluorescence cross-correlation spectroscopy (point FCCS) analyzes the fluctuation of fluorescent-labeled molecules in two colors. The coincidence of fluctuations occurring in two detection channels shows that the two proteins are part of the same complex.

point FCS and point FCCS can now be performed with a standard detector, eliminating the need for a special high-sensitivity detector.

FRAP Analysis

The Axelrod analytical algorithm is installed as a FRAP analysis method. The algorithm is used to calculate diffusion coefficients and the proportions of diffusing molecules.

Analytical methods according to molecule diffusion speeds

point FCS

Capable range

of measurement RICS

FRAP

Small molecules in solution

> 100

Proteins in solution

~ 100

Diffusion of proteins in cell

1 ~ 100

Lateral diffusion in cell membrane

< 0.1

Protein trafficking

< 0.01

Molecular complex

formation, aggregation

<< 0.001

15

Image 16
Contents FV1000 FLUOVIEW--From Olympus is OpenImaging to Analysis Ing up New WorldsAdvanced Fluoview Systems Enhance the Power of Your Research Page Laser combiner/Fiber Excellent Precision, Sensitivity and StabilityScanners/Detection Optical System IcitySamples and Specimens Spectral Based Detection Filter Based DetectionSIM Simultaneous Scanner Unit Simultaneous Laser Light Stimulation and ImagingWide Choice of Bleaching Modes Multi-Purpose Laser CombinerImproved Flatness and Resolution at 405 nm NEW Low Chromatic Aberration ObjectiveBest Reliability for Colocalization Analysis Flatness Comparison Image at 1x ZoomFV1000MPE Multiphoton Excitation System User-Friendly Software to Support Your Research Re-Use Function Help GuideMulti Stimulation Software Multi-Area Time-Lapse SoftwareFret Multi-Dimensional Time-Lapse 3D/4D Volume RenderingMeasurement Light StimulationDiffusion Measurement Package RICS-Raster Imaging Correlation SpectroscopyPoint FCS-Point scan Fluorescence Correlation Spectroscopy Frap AnalysisRics Application and Principles Rics PrincipleRics Analysis Method Spatial Correlation AlgorithmLaser Light Stimulation FRAP-Fluorescence Recovery after PhotobleachingFLIP-Fluorescence Loss in Photobleaching Uncaging PhotoconversionMulti-Point Laser Light Stimulation Multi-Dimensional Time-Lapse Significantly Improved Long Time-Lapse ThroughputFocal Drift Compensation for Long Time-Lapse Imaging Maintain Cell Activity Over a Long PeriodMosaic Imaging for 3D XYZ Construction 3D Mosaic ImagingAutomated from 3D Image Acquisition to Mosaic Imaging Expandability to Support Diverse Application AnalysisMCherry 405 UltiNHeNe Ree 458 473 488 515Optional Upgrade Equipments for FV1000 Scanning UnitsLaser Systems Illumination UnitsCO2 Incubator FV1000 System DiagramHigh-Precision Motorized Stage/ Prior H117 Main Specifications Using U-UCD8A-2, IX2-LWUCDA2 and U-DICTSUsing WI-UCD, WI-DICTHRA2 Objectives for BX2Recommended FV1000 system setup IX81, BX61, BX61WI Dimensions, Weight and Power ConsumptionImages are courtesy of the following institutions Fluoview website Olympus Corpoaration is ISO9001/ISO14001 certified