Olympus FV1000 manual Expandability to Support Diverse Application, Analysis

Page 22

Expandability to Support Diverse Application.

 

 

 

 

Application

Standard Functions

Optional Functions

Molecular interaction and

 

Intracellular diffusion measurement

molecular concentration

 

Calculation of diffusion coefficients for intracellular molecules, and analysis of

analysis

molecular binding and changes in molecular density.

 

 

 

 

 

 

 

Supports a wide range of methods (RICS/ccRICS, point FCS/point FCCS and

 

 

 

 

 

 

 

 

1.5

 

 

 

 

 

 

 

FRAP).

1

 

 

 

 

 

 

 

Software Required: Diffusion measurement package

0.5

 

 

 

130

 

 

 

 

 

 

 

125 Pixels

 

 

 

0

 

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

125

105

 

 

 

 

 

 

Pixels

130

 

 

 

 

Laser Light stimulation

Acquires images while rapidly switching

SIM scanner system

 

 

 

 

 

 

 

the built-in laser between imaging and

Performs simultaneous imaging and laser light stimulation. Provides detailed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

laser light stimulation.

settings for laser light stimulation including position and timing.

 

 

 

 

 

 

 

Features tornado scanning for high-

Features tornado scanning for high-efficiency bleaching using laser light

 

 

 

 

 

 

 

efficiency bleaching using laser light

stimulation.

 

 

 

 

 

 

 

stimulation.

Equipment Required: SIM scanner, laser combiner (dual fiber version)

 

 

 

 

 

 

 

 

Multi-point laser light stimulation system

 

 

 

 

 

 

 

 

Register multiple points for laser light stimulation, and program the respective

 

 

 

 

 

 

 

 

stimulation order, stimulation time and type of stimulation (continuous laser light

 

 

 

 

 

 

 

 

or pulse laser light).

 

 

 

 

 

 

 

 

Software Required: Multi-stimulation software

Multi-dimensional

 

Long time-lapse system

time-lapse imaging

 

Microscopes equipped with zero drift compensation (ZDC) acquire each image at

 

 

 

 

 

 

 

 

a set focus plane. The microscope CO2 incubator maintains cell activity for a long

 

 

 

P2

 

 

 

 

 

P1

 

P3

 

 

period for continuous imaging.

 

 

P5

P4

 

Equipment Required: IX81-ZDC microscope, CO2 incubator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-point scanning system

 

 

 

 

 

 

 

 

Register multiple points for repeated image acquisition. Efficiently observe multiple

 

 

 

 

 

 

 

 

cells in parallel on 35-mm dishes, microplates or chamber slides.

 

 

 

 

 

 

 

 

Software and Equipment Required:

 

 

 

 

 

 

 

 

Multi-area time-lapse software, motorized XY stage**

3D mosaic imaging

 

3D mosaic imaging system

 

 

 

 

 

 

 

 

Continuous imaging of adjacent fields of view and mosaic imaging to form a

 

 

 

 

 

 

 

composite image.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acquisition of adjacent Z-series images for 3D mosaic imaging.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Software and Equipment Required:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multipoint time-lapse software, motorized XY stage**

 

 

 

 

 

 

 

 

TIRFM

 

 

 

 

TIRFM imaging

 

 

 

 

 

 

 

 

Uses the laser from the laser combiner to provide evanescent illumination, for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

imaging the movement of molecules near the glass surface, such as cell

 

 

 

 

 

 

 

membranes and adhesion factors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Software and Equipment Required: TIRFM unit*, TIRF objective, high-

 

 

 

 

 

 

 

 

sensitivity CCD camera**, CCD camera control software**

FRET

 

 

 

Provides FRET analysis functions.

CFP-YFP FRET

 

 

 

 

 

 

 

Diode laser offers exceptional stability

Ratio imaging and sensitized emission.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and long life.

Available 440 nm diode laser is optimized for CFP-YFP FRET experiments

 

 

 

 

 

 

 

Supports FRET efficiency

methods.

 

 

 

 

 

 

 

measurements using acceptor

Diode laser offers exceptional stability and long life.

 

 

 

 

 

 

 

photobleach method.

Equipment Required: LD 440 nm Laser

Multi-color imaging

Three-channel detector for

Imaging blue dyes

 

 

 

 

 

 

 

simultaneous acquisition of

Available 405-nm laser for image acquisition of multi-stained samples labeled with

 

 

 

 

 

 

 

fluorescence images from three

V-excitation fluorescent dyes such as DAPI, Hoechst and Alexa 405.

 

 

 

 

 

 

 

different dyes.

Equipment Required: LD 405 nm laser

 

 

 

 

 

 

 

Sequential mode for acquisition of

 

 

 

 

 

 

 

 

fluorescence images without cross-talk. Simultaneous four-color imaging

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fluorescence can also be separated

Fourth channel detector can be easily added to simultaneously acquire images of

 

 

 

 

 

 

 

four colors.

 

 

 

 

 

 

 

using unmixing (only available on

 

 

 

 

 

 

 

Equipment Required: 4-channel detector

 

 

 

 

 

 

 

spectral scan unit).

 

 

 

 

 

 

 

 

Colocalization analysis

Easily determine if labeled substances

High-accuracy colocalization analysis

 

 

 

 

 

 

 

are present locally in the same

New 60x oil-immersion objective offers image acquisition with exceptional

 

 

 

 

 

 

 

locations.

positional accuracy coefficient.

 

 

 

 

 

 

 

Calculate of Pearson coefficients,

Equipment Required: PLAPON 60xOSC

 

 

 

 

 

 

 

overlap coefficients and colocalization

 

 

 

 

 

 

 

 

indices.

 

 

 

 

 

 

 

 

 

 

*SIM scanner and TIRFM scanner cannot be installed on the same system.

**For more information about peripheral equipment, contact your Olympus dealer.

21

Image 22
Contents FV1000 FLUOVIEW--From Olympus is OpenImaging to Analysis Ing up New WorldsAdvanced Fluoview Systems Enhance the Power of Your Research Page Laser combiner/Fiber Excellent Precision, Sensitivity and StabilityScanners/Detection Optical System IcitySamples and Specimens Spectral Based Detection Filter Based DetectionWide Choice of Bleaching Modes SIM Simultaneous Scanner UnitSimultaneous Laser Light Stimulation and Imaging Multi-Purpose Laser CombinerBest Reliability for Colocalization Analysis Improved Flatness and Resolution at 405 nmNEW Low Chromatic Aberration Objective Flatness Comparison Image at 1x ZoomFV1000MPE Multiphoton Excitation System User-Friendly Software to Support Your Research Multi Stimulation Software Re-Use FunctionHelp Guide Multi-Area Time-Lapse SoftwareFret Measurement Multi-Dimensional Time-Lapse3D/4D Volume Rendering Light StimulationPoint FCS-Point scan Fluorescence Correlation Spectroscopy Diffusion Measurement PackageRICS-Raster Imaging Correlation Spectroscopy Frap AnalysisRics Analysis Method Rics Application and PrinciplesRics Principle Spatial Correlation AlgorithmLaser Light Stimulation FRAP-Fluorescence Recovery after PhotobleachingFLIP-Fluorescence Loss in Photobleaching Uncaging PhotoconversionMulti-Point Laser Light Stimulation Focal Drift Compensation for Long Time-Lapse Imaging Multi-Dimensional Time-LapseSignificantly Improved Long Time-Lapse Throughput Maintain Cell Activity Over a Long PeriodMosaic Imaging for 3D XYZ Construction 3D Mosaic ImagingAutomated from 3D Image Acquisition to Mosaic Imaging Expandability to Support Diverse Application AnalysisNHeNe Ree MCherry405 Ulti 458 473 488 515Laser Systems Optional Upgrade Equipments for FV1000Scanning Units Illumination UnitsCO2 Incubator FV1000 System DiagramHigh-Precision Motorized Stage/ Prior H117 Using WI-UCD, WI-DICTHRA2 Main SpecificationsUsing U-UCD8A-2, IX2-LWUCDA2 and U-DICTS Objectives for BX2Recommended FV1000 system setup IX81, BX61, BX61WI Dimensions, Weight and Power ConsumptionImages are courtesy of the following institutions Fluoview website Olympus Corpoaration is ISO9001/ISO14001 certified