Safety concept

The individual modules of the Leica M stereo- microscopy series include an interactive CD-ROM with all relevant user manuals in 20 other languages. Keep it in a safe place, and readily accessible to the user. User manuals and updates are also available for you to download and print from our web site at www.stereomi- croscopy.com.

This operating manual describes the special functions of the individual modules of the Leica M stereomicroscopy series and contains impor- tant instructions for their operational safety, maintenance, and accessories.

The "Safety concept" booklet contains addi- tional safety information regarding the service work, requirements and the handling of stereo- microscope, accessories and electrical accesso- ries as well as general safety instructions.

You can combine individual system articles with articles from external suppliers (e.g. cold light sources, etc.). Please read the user manual and the safety requirements of the supplier.

Before installing, operating or using the instru- ments, read the user manuals listed above. In particular, please observe all safety instruc- tions.

To maintain the unit in its original condition and to ensure safe operation, the user must follow the instructions and warnings contained in these user manuals.

Leica M series

Manual

3

 

 

 

Image 3
Contents Leica M125 Leica M165 C Leica M205 C Leica M205 a Manual General Instructions Safety concept Action Symbols usedImportant information Provide clarityNon-intended use Safety regulationsDescription Designated useDisposal Legal regulationsTransport EC Declaration of Conformity Light sources safety instructions Mercury lamp During maintenance work on the supply unitLamp housing Supply unitTable of Contents Microscope Carrier AX Objective Nosepiece Different Types of ObjectivesLeica LED5000 MCI Leica LED5000 RL IsoPro Motorized XY Stage 110 Care, Maintenance, Contact Persons 113Leica PSC Controller 109Leica M Series Congratulations Limits are made to be broken Step Towards InfinityFewer cables Reliability for your experimentsHave a special request? Let us know Modular Design Everything is RelativeEyepieces Maximum CompatibilityObjectives TubesOn We Go Assembly Hex socket screwdriver, 3 mm Base and Focusing ColumnAssembling the column adapter Assembling the focusing drive Tools usedHex socket screwdriver, 4 mm Optics carrierAssembling the tube TubeNo tools required PreparationsEyepieces Tools used PreparationMagnification range Remove the protective cap on the optics  bly and disassembly so that it does not Instructions onObjective Larly to the 2× planapochromatic objectiveRemove the transport anchor from the objective nosepiece Objective Nosepiece AssemblyAssembly Do not fall onto the stage plateObjective Nosepiece Adjusting Parfocality AdjustmentTighten the locking screws Hex socket screwdriver, 2.5 mm Check the switch positionAX Carrier Preparation ToolsHex socket screwdriver, 4 mm Philips screwdriver AX Carrier AssemblyTransmitted-light Base TL ST Unpacking the base Focusing drive and columnAnchors as follows Removing the transport anchorsStandard stage Stage assemblyTransmitted-light Base TL Bfdf Standard deliveryTL RC / TL RCI IsoPro Manual Cross-stage Assembly IsoPro Cross-stageLeft or right operation Control assembly Cross-stage assemblyPlace the cross-stage on the base Focusing drive and column Basics IsoPro Motorized Cross-stage AssemblyIsoPro Motorized Cross-stage Assembly Bases Cross-stage and baseDamaged Place the cross-stage on the base Cross-stage for X-Y Stage Control Module Cables Terminals Interface to the optics carrier is on the columnTerminals Feeding the cables Cables Cable DuctAlternative installation Cables DiagramStirrups on both top holes on the drive hous Ing Leica LED5000 MCIHold the LED5000 MCI with one Hand and tightly screw the retraining Be facing downwardsInstallation on the column Leica LED5000 MCI Alternative AssemblyColumn Leica LED5000 RLMust be facing upwards Into placeQuick Start Guide Fastest Route to Success Overview of an M series Microscope Look into the eyepieces Adjusting the Interpupillary DistanceCorrect Interpupillary Distance Reference valueIf you wear glasses Using the EyepiecesDioptric correction If you do not wear glassesCoarse/fine adjustment FocusingFocusing drive can be operated either left- or right-handed FocusingAdjusting the resistance Adjusting the resistance of the focus driveChanging the magnification zoom ZoomingLook into the eyepieces Focus on the specimen Ratchet Steps and Magnification Levels Enabling and disabling ratchet stepsMagnifications and fields of view Enlarge the view to the maximum level Focus on the specimen Parfocality More Comfort and Convenience for Your WorkRequirements for parfocal work ParfocalityIris Diaphragm Closing the iris diaphragmOpening the Iris Diaphragm Eyepieces Following eyepieces are available for the M series Magnification Factors of the EyepiecesHealth Notes Potential sources of infectionLeica partner Dioptric correction Using the Dioptric CorrectionDioptric Correction and Parfocality AdjustingConvergence angle in the stereoscopic image GraticulesUse Use with the AX carrierPhotography & Video Leica Application Suite Photography & VideoAdapter Leica DFC camerasPhoto tubes and C-mounts Trinocular video/phototube 50% Trinocular video/phototube 100% SwitchoverMicroscope Carrier Microscope Carrier AX CompatibilityStereoscopic viewing Coaxial light and the Leica M205 C Parallax-free imagesTechnical constraints Objective NosepieceParfocal work Objective changeObjectives Optical accessories Achromatic objectives with a long focal length Different Types of ObjectivesAchromatic objectives Planachromatic objective 1×Bases Transmitted-light Base TL ST Controls Bright field Transmitted-light Base TL ST OperationLight intensity control Transmitted-light controlTransmitted-light Base TL ST Lamp Replacement Precautionary measuresChanging the Halogen Lamp Transmitted-light Base TL Bfdf Controls Adapter at the focusing driveTurn the control as far as it will go towards DF dark field Transmitted-light Base TL Bfdf OperationLight source Dark fieldTL RC / TL RCI Controls Functions of the rotary knob TL RCI The Deflection MirrorInverted world? Tilted mirrorUsing a USB mouse only TL RCI TL RCI Color Intensity and TemperatureTL RC / TL RCI Operation Setting the relief contrastSuitable for fixed specimens and fine struc- tures TL RCI Methods in Transmitted LightVertical bright-field illumination Single-sided dark fieldNegative relief contrast TL RCI Relief ImagesStarting position Positive relief contrastSuitable for semitransparent and transparent specimens Dynamic relief contrastUsing Filters Filters for TL RC and TL RCIDaylight filter for TL ST Operating the cross-stage IsoPro IsoPro Non-motorized ControlsIsoPro Motorized Controls IsoProStage DCI module System Illumination Antees the reproducibility of an experiment Use Contact with the baseBeneath the MCI Bottom end of the guide rodsMaximum brightness Using the keyboardUse the key to switch the illumination on or off Illumination scenariosConstraint Accessories Fine control of the cross-stage Leica PSC ControllerConnection Passing over the specimen quicklyDimensional Drawings Leica M125 / M165 C 292 217 431 537 154 106 356 430 340 292 217 547 116 385 154154 340 390 440 Leica M series Manual 100 Leica M205 C Leica M series Manual 102 Leica M series Manual 103 Leica M series Manual 104 Leica M series Manual 105 Specifications for the Bases Illumination types Ambient temperature 10-40 CConnections Power plug, power switch Weight Energy consumption 30 W maxConcave mirror *** With external light source Internal shutter/lamp control Yes Integrated filter holderActive f=10 mm, end tube f=13 mm Weight Leica TL RC Leica TL RCIConcave mirror **** With external light source Compatibility IsoPro Motorized XY StageAppendix Parameter ExampleCalculation example magnification in binocular tube Mail contact Care, Maintenance, Contact PersonsWarranty benefits Contact addressDust and dirt will affect the quality of your results Keep accessories in a dust-free place when not in useCleaning polymer components Protection from dirt