Leica MZ16 F Repairs and servicing, Installation in third-party products, Disposal, Health risks

Page 8

Repairs and servicing

Only Leica Microsystems-trained service tech- nicians, or technical specialists assigned by the person in charge of the instrument, are permitted to carry out repairs.

Only original Leica Microsystems spare parts may be used.

Disconnect the power cable before opening voltage-carrying parts such as the power supply or the supply unit.

Touching the live circuit can cause injury.

Installation in third-party products

When installing Leica products into third-party products, note the following:

The manufacturer of the complete system or its dealer is responsible for following all applicable safety instructions, laws and guidelines.

Disposal

The product must be disposed of in accordance with locally applicable laws and regulations.

Dispose of used high-pressure mercury burn- ers as hazardous waste.

Legal requirements

Adhere to general and local regulations relating to accident prevention and environmental protec- tion.

Conformity with European Community directive

The Leica MZ16 F and its accessories are con- structed in accordance with the latest technolo- gies and are provided with a statement of confor- mity with EC requirements.

Health risks

Workplaces with stereomicroscopes both improve and make visual tasks easier, but they also place high demands on the human visual apparatus and the muscular "holding apparatus" of the user. Depending on the duration of uninter- rupted work, asthenopia and musculoskeletal problems may occur. For this reason, appropriate measures for reduction of the workload must be taken:

optimal arrangement of workplace, work assignments and work flow (changing tasks frequently).

thorough training of the personnel, giving consideration to ergonomic and organization aspects.

The ergonomic design and construction of Leica M series stereomicroscopes are intended to reduce the exertion of the user to a minimum.

Direct contact with eyepieces is a potential transmission method for bacterial and viral infec- tions of the eye.

The risk can be kept to a minimum by using per- sonal eyepieces for each individual or detachable eyecups.

8

Leica MZ16 F – Safety concept

Image 8
Contents Leica MZ16 F Dear User Operating controls Contents Safety concept DiagramsSymbols used Safety instructionsPermitted uses Non-intended usePlace of use Responsibilities of the persons in charge of instrumentInstallation in third-party products Repairs and servicingDisposal Legal requirementsLight source safety instructions Precautions by the manufacturerLamp housing Risk of explosion, UV exposure, blinding Supply unitOverview of the instrument Leica MZ16 F Overview of the instrument Microscope components are best assembled in this order AssemblyAssembly sequence Expansion diagram MZ16 FAAssembly of stereomicroscope with stand Lamp housing 106 z Supply units Additional componentsVideo/photo tube Light sourceEquipping the filter changer CarrierFilter sets for fluorescence Light spot seeSimple filter holders Slot for filter slideInserting the filter Insert a total of four filter holdersStereomicroscope settings and adjustments OperationDescription Fluorescence technology Functional principleDouble iris diaphragm Observation without fluorescenceCommissioning the fluorescence system Rapid filter changerWait for 2 to 3 minutes Filter setsWork flow Filter sets Excitation filter Barrier filter Designation AppendixFilter sets Fluorescence system Leica MZ16 F Technical dataOptics carrier Leica MZ16 F Optical accessories Leica MZ16 F Leica MZ16 F Optical DataVarious accessories Stands, illuminators Leica MZ16 FLeica MZ16 F Technical Data Weights Focusing drive, coarse/fine Maximum load 15 kgEbq 100 supply unit Column with motorized focusOptical data ObjectivesDimensions Dimensions in mmPage Leica Microsystems the brand for outstanding products