Siemens SIMATIC PCS 7 brochure Monitoring and diagnostics

Page 24

Overview device functions

Motor contactor with RLT

SIRIUS compact starter and infeed system for 3RA6

SIRIUS motor starter M200D

innovative solution for dis- tributed drive technology

3RW44 soft starter

SIMOCODE pro 3UF7

© Siemens AG 2011

Tried and tested SIRIUS technology

3 sizes S6, S10, S12 (55 to 250 kW at 400 V)

Can be used up to 60 °C without derating

Long electrical service life

Replaceable main current contacts

LED display of the remaining life time of the main current contacts (60%, 40%, 20%)

With 20% or less remaining life time, a message is sent via AS-Interface

Connection via AS-Interface

Compact starter up to 32 A as direct and reversing starter, 45/90 mm wide

Only one weld-free clearance, instead of circuit breaker, contactor, and overload relay

Electronic trigger with wide setting range 1:4 (5 versions)

Integrated overload function with differentiated fault message

Infeed system up to 70 mm² and 100 A

Connection via AS-Interface

Degree of protection IP65 allows application-oriented setup without a control cabinet

Protects, switches, and monitors the motor and application

Parameterization via STEP 7 HW Config

Connection to AS-i, PROFIBUS, and PROFINET

Little variance for all motor starter versions

Manual operation and main switch are integrated

Electronically controlled start-up and coasting of asynchro- nous motors

Integrated jumper contact system

Integrated motor overload intrinsic device protection

Adjustable current limiting

Integrated status and fault monitoring

Torque control

Integrated braking function (superimposed DC braking)

Compact design

5 sizes for the power range from 15 to 710 kW

Recording the active power

Connection via PROFIBUS

Intelligent connection of distributed drives to the control level

Autonomous function without PLC or bus

Comprehensive monitoring functionality

Graphical parameterization

Analog inputs/outputs for application monitoring

Integrated inputs/outputs for motor and application monito- ring

Can be used for all motor applications

Flexible motor management system with integrated protec- tion, control and monitoring functions

Intelligent pre-processing is possible

Modularly expandable system

Outputs for activating motor contactors

Connection via PROFIBUS

can also be used for safety functions (locally or via PROFIsafe)

24Monitoring and diagnostics

Image 24
Contents Maintenance System Increase in productivity through intelligent maintenance Maintenance strategiesBenefits of intelligent maintenance IntroductionContents Plant Asset Management as a maintenance task Maintenance personnelGeneral information Different demand for information at the plantAsset management in production Benefits of Plant Asset ManagementIntelligent maintenance in process engineering Plant Asset Management with Simatic PCSIntegrated plant and cross-system maintenance Optimizing instead of repairingSimatic PCS 7 Maintenance Station More productivity with Totally Integrated AutomationVisualization of information for maintenance Maintenance Station User interface for maintenance Monitoring and diagnostics of mechanical componentsPump monitoring with the block PumpMon Valve monitoring with the block ValveMonStandard diagnostics functions Design of a Maintenance StationConfiguring a Maintenance Station Visualization in the Maintenance StationSymbol displays and component faceplates MaintenanceIdentification MessagesAlarm Control Center alarm management system PM-MAINT intelligent maintenance managementMaintenance planning Archiving of maintenance dataMonitoring Signaling Alerting Visaulization Operating Monitoring and diagnosticsFor industrial PCs Prevention of potential failuresMonitoring and diagnostics of networks Monitoring of PROFINET/Industrial EthernetNetwork components Network managementBenefits of network monitoring and diagnostics Monitoring of ProfibusDiagnosis of optical Profibus links with OLM Temperature measurement Sitrans TH300 the Hart deviceSitrans TH400 for Profibus PA Sitrans TW for rail mountingΜS/cm guaranteed Flow measurementLevel measurement Sitrans Probe LR, pulse radarGas analyzers Calomat 6/62Remote service Process gas chromatographyMaxum edition MicroSAMMonitoring and diagnostics for positioners and valves Sitrans VP300Monitoring and diagnostics of 24 V load feeders Temperature Ground fault or insulation detectionContact erosion Number of starts, breaking currentMonitoring and diagnostics Monitoring and diagnostics of drive components Diagnostics of drivesStatus assessment of high-voltage machines Schematic flow of information using example of a mixer drive Benefits Get more information