Siemens NI-1200 Local Feature Inspection, System Feature nspection, Idle Line Inspection

Page 53

Issue 5, June 1999

of inspection can be made, each depending on the status of the key being inspected: Local Feature Inspection, System Feature Inspection, Idle Line Inspection. and Active Call Inspection.

Local Feature Inspection

With Feature Key Inspection turned on (refer to Feature Key Inspection), you can verify the feature assigned to any local feature key by simply pressing that key. The Optiset terminal will display, for 5 seconds, information about the assigned feature. The lower line of the display will identify the feature (Speaker, Speed Dial, etc.). and the upper line will display appropriate additional information, such as the name or ON associated with a Speed Dial key.

System Feature 'nspection

With Feature Key Inspection turned on (refer to Feature Key Inspection), you can verify the switching-system based feature assigned to a feature key by simply pressing that key. The Optiset terminal will send a Feature Inspection request to the switching system, which will then return information about the feature assigned to the key. The terminal will display the information for 5 seconds.

Idle Line Inspection

With Feature Key Inspection turned on (refer to Feature Key Inspection), you can verify the ON assigned to an idle line key by simply pressing that key. The Optiset terminal will send a Feature Inspection request to the switching system, which will then return the ON assigned to the key. The terminal will display the ON for 5 seconds.

Active Call Inspection

With Feature Key Inspection turned on (refer to Feature Key Inspection), you can obtain switch-generated information about a call that is active on a line assigned to a specific line key by simply pressing that key. The Optiset terminal will send a Feature Inspection request to the switching system, which will then return

94

1275·00030

Issue 5, June 1999

information about the call associated with the key. If the call is the currently active call, the duration of the display is determined by the switching system. If the call is a background call. the terminal will display the information for 5 seconds.

Group Pickup

Group Pickup is a switch-based feature that allows you to answer a call that is ringing on any of the phones in a group of phones that have been listed with your telephone operating company as a pickup group. If your Optiset terminal is subscribed to this feature, it is available through the menu display when you go off-hook. When you hear a phone in your pickup group ringing. simply go off­ hook and press the t/ dialog key to answer the call.

Note: Group Pickup ceases to be available as soon as you begin dialing an out-going call.

Hold

Hold is a combined local/switch-based feature that is used to put either a single party or a conference on hold so you can answer or make another call. The feature can be activated either by pressing the Hold feature key or by selecting the Hold? menu option from the menu display. Either action sends a Hold request to the central­ office SWitching system.

When a Hold Acknowledge is received from the switching system, the Optiset terminal will isolate the call from the terminal's acoustic circuits, and the Hold status light will turn on. If the Hold request is rejected by the switching system, the current call state of the terminal will not change, and an error message may be sent to the terminal by the switching system.

For non-EKTS calls, the line key status light indicates that a particular call is on hold. For EKTS calls, the line key status light indicates "that the call is on hold in the entire EKTS group. This condition must be recognized and acknowledged by the switching system before the Optiset terminal will cause the line key status light to give the Hold indication.

1275·00030

95

Image 53
Contents OPTISET@ NI-1200 Issue Date Issued Issue InformationContents Summary of Issue EnhancementsAlternative Call Operations Menu Trees LJ~UJ Introducing Your OptisetProgramming Requirements Switching System National Isdn Compliance IssuesIssue 6, June Optional Headset Volume UpNolume Down KeysMicrophone Basic Electronic Key Telephone Service Types of Service SupportedBaaic Isdn Terminal Multiline Hunt Group1275-00030 IDial 1555-5555 Place a Call Using the Handset Procedure DisplayBasic Call Operations Ithu FEB 04, 99 0943 ~~ 555-5555 01 00555-5555 010000 THU FEB 04, 99 0943 AMAnswer call? 555-55551I0ld? Retrieve call line 1?5SS-SS55 01 00 555-55!J5 Ilold?Hold? 555-5555 010012Ringing Cancel Conference? 555-5565Ringing IconferenceI 555-5555 010522Conference? Cancel Conference?Drop last party? Alternative Call Operations 1275·00030 1275·00030 Illue 5, June Hold a Call Clear a CaliOn Hold88U8 5, June Transfer a Call Ssue 5, June Password Prompt USER-CONTROLLED Terminal SettingsAssign, Change, or Delete Password Enter passwordPhone configuration Verify new passwordPassword? Phone configuration MenuInitial settings? Configure phone?Audio settings? Audio settings Ringer pitch?Speaker Loudness Audio settings Handset loudness?Audio settings Ringer loudness? Key click setting? Audio settings Speaker loudness?THU FEB 04, 99 0955 AM Key clicks Orf Turn on key clicks?Busy Alerting Type Procedure Display Audio settings Busy alerting type?1i ck Sett i ng? Muted ring selected Select attention tone?Menu overlay delay?O Local featuresLocal Features? THU FEB 04 0955 AMSpeaker is enabled Oisable speaker? Loca I features Speaker control?Line hold mode Change to line preview? Line preview mode Change to line hold?Menu Is disabled Activate menu mode? Mellll is demand Dilly Disable menu mode?Loca I features Menu setting? Menu Setting ProcedureDisplayHot keypad mode Select composed dial? Phone configuration menu 1 ­ Initial settings?Composed dial mode I Activate menu mode? Hot Keypad ProcedureDisplayLoca I features Speaker setting? Loca I features Hot keypad setting1Speaker single Talk Single talk? Loca I features Speaker Double talk Double talk?Incoming Call Display ProcedureDisplay Loca 1 features Incoming call disp?Off Hook Result Procedure Display 0 to 9 seconds Enter call display timePhone configuration menu Initial settings? Local features? Loca features Off hook result?Loca I features Off hook result? Local features Menu overlay delay? Fast transfer?Press the II dialog key to select the local Features menu Local features Fast transfer?Use a combination of the .J Use the .J and I dialogPress the t/ dialog key to select the Local Features menu Local features Autoanswer mute?THU fEB 64, 99 6955 AM To change the Fast TransferMo XX Day XX Year Set date?Enter Date Mo 05 Day 22 YearOptiset Terminal Used AS AN Ekts Phone 1275·00030 1275-00030 Intercom ConferencelTransfer Call AppearanceHold Plugging Headset Controlling the Headset Using the PlugHeadset Operation Controlling the Headset Using Keys or Menu Options Features Conference/Large Conference 1275·00030 Download System Feature nspection Local Feature InspectionIdle Line Inspection Active Call InspectionMute Line Status/Speed DialMake Busy 188ue 5, June 100 1275-00030 UUS Answering Redial Menu TreesAuto Callback Call Alerting Incoming Call AlertingOutgoing Call Offhook Outgoing Call· DialingRelease this call? Retrieve line x? Transfer call? Clear download message? Call Log AccessedIndex CACH,9 Ssue 5, JuneMenu Trees TA-TAPI Issue 5, June

NI-1200 specifications

The Siemens NI-1200 is a versatile and innovative device designed for a wide range of automation and control applications. As part of Siemens' extensive portfolio, the NI-1200 showcases cutting-edge technologies and features that enhance operational efficiency and flexibility in industrial environments.

One of the main features of the NI-1200 is its robust processing power. With a high-performance processor, the device is capable of handling complex automation tasks in real-time. This enables seamless integration with various automation components, allowing for greater control and monitoring of processes.

The NI-1200 is equipped with advanced communication capabilities, supporting various industrial communication protocols such as Ethernet/IP, Profinet, and Modbus. This extensive connectivity makes it easy for the device to interface with other systems, sensors, and actuators, promoting interoperability and data exchange across different platforms.

In terms of data handling, the NI-1200 offers rich data logging and analysis features. Users can collect, store, and analyze data from different sources, which is essential for process optimization and troubleshooting. This capability ensures that organizations can make informed decisions based on accurate and timely data, ultimately leading to improved productivity and reduced downtime.

The device is also designed with scalability in mind. Whether organizations are looking to implement a small-scale solution or require extensive systems integration, the NI-1200 can adapt to changing needs. Its modular design allows for easy upgrades and expansions, catering to future growth and evolving technology landscapes.

Another key characteristic of the Siemens NI-1200 is its user-friendly interface. The device features an intuitive graphical user interface (GUI) that simplifies configuration and monitoring tasks. This ease of use reduces the learning curve for operators and maintenance personnel, enhancing overall productivity.

Additionally, the NI-1200 is built with durability and reliability in mind, suitable for harsh industrial environments. It complies with international standards for safety and environmental conditions, making it a dependable choice for various applications, including manufacturing, process control, and building automation.

In summary, the Siemens NI-1200 is a powerful and feature-rich automation device that stands out for its processing capabilities, communication options, scalability, and user-friendly interface. Its combination of advanced technologies and robust characteristics makes it an ideal solution for organizations looking to enhance their automation and control processes. With the Siemens NI-1200, businesses can achieve greater efficiency, flexibility, and reliability in their operations.