VeriFone Omni 37xx manual Transactions Fail To Process, If the keypad does not respond properly

Page 35

Keypad Does Not Respond

Transactions

Fail To Process

TROUBLESHOOTING GUIDELINES

Keypad Does Not Respond

If the keypad does not respond properly:

Check the LCD screen. If it displays the wrong character or nothing at all when you press a key, follow the steps outlined in Transactions Fail To Process.

If pressing a function key does not perform the expected action, refer to the user documentation for that application to ensure you are entering data correctly.

If the problem persists, contact your local VeriFone representative for assistance.

There are several possible reasons why the terminal may not be processing transactions. Use the following steps to check troubleshoot failures.

Check Magnetic Card Reader

Perform a test transaction using one or more different magnetic stripe cards to ensure the problem is not a defective card.

Ensure that you are swiping cards properly. With the Omni 37xx card reader, the black, magnetic stripe on the card should face inward, toward the keypad.

Process a transaction manually using the keypad instead of the card reader. If the manual transaction works, the problem may be a defective card reader. Contact your VeriFone distributor or service provider. If the manual transaction does not work, proceed to Check Telephone Line.

Check Smart Card Reader

Perform a test transaction using several different smart cards to ensure the problem is not a defective card.

Ensure that the card is inserted correctly.

Ensure the MSAM cards are properly inserted in the cardholders and the cardholders are properly secured (see Install/Replace MSAM Cards).

Process the transaction manually using the keypad instead of the card reader. If the manual transaction processes, the problem may be a defective card reader. Contact your VeriFone distributor or service provider. If the manual transaction does not process, proceed to Check Telephone Line.

Check Telephone Line

Disconnect the telephone line from the back of the Omni 37xx terminal and connect it to a working telephone to check for a dial tone. If there is no dial tone, replace the telephone cable.

If the problem appears to be with the telephone line, check with the party you are trying to call to see if their system is operational. If they are not experiencing difficulties with their line, contact the telephone company and have your line checked. If the telephone line works, contact your local VeriFone representative for assistance.

OMNI 37XX INSTALLATION GUIDE

35

Image 35
Contents Omni Omni 37xx Installation Guide VeriFone, Inc Contents Guidelines VeriFone ServiceTroubleshooting SupportPreface URL Terminal Overview Features At a GlanceExceptional Ease Of Use Features BenefitsFactors EnvironmentalElectrical Unpack Shipping CartonAn LCD screen Examine Terminal FeaturesConnection Ports Back Panel Establish Telephone Line Connections Install Paper RollTo Install a Paper Roll Accessories and Documentation sectionRemoving Partial Paper Roll Msam Cards Install/ReplaceTo change or install SAMs Msam Compartment Door and Locking Screw To Connect PIN Pad, Smart Card Reader, or Bar Code Wand Connect Optional DevicesConnect PIN Pad, Smart Card Reader, or Bar Code Wand Smart Card Reader Connection CR 600 Check Reader Connection Connect Terminal Power PackOmni 37xx Power Pack Connection To Conduct a Smart Card Transaction Routing Cables Using Wire ClipsTo Conduct a Credit/Debit Card Transaction Magnetic Card Reader UseMagnetic Card Reader Use Power DC Power Pack Temperature External Dimensions Weight SpecificationsSpecifications Reader Smart CardSmart Card Reader Returning a Terminal for Service VeriFone Service and SupportDownload Cables Cables for Optional Peripherals Accessories DocumentationTelephone Line Power PackWire clip VeriFone CleaningAccessories and Documentation Blank Display Troubleshooting GuidelinesPeripherals Device Does Not Work Printer Does Not PrintPrinter Paper Jam If the keypad does not respond properly Transactions Fail To ProcessTransactions Fail To Process Index Index Installation Guide