Installation and Maintenance Manual
Installing the Central Control Unit
CCU Location(CCU)
The CCU is intended for installation in a residential or
Do not site the CCU where it will be subjected to excessive levels of heat, dust, damp or high humidity. Locating the equipment near sources of electromagnetic radiation, such as heavy electrical switch gear, lift machinery or electric arc welders, should be avoided.
Allow at least 150 mm of free space all around the CCU for ventilation.
The CCU needs to be located within two metres of a dedicated mains power supply outlet. The CCU must not share the same mains supply socket with any other electrical appliance.
Mounting the CCU
When a suitable location has been found, mark the screw locations on the mounting surface, using the mounting bracket provided.
If the CCU is being mounted on masonry or plasterboard, suitable wall plugs must be used. Drill and plug four holes in the wall at the marked locations. The holes should be deep enough to accept a 2.5cm screw.
Wall mount bracket