Menu Mode

Menus, SERVICE, MIC GAIN

MIC GAIN adjusts mic gain from -15dB to +15dB. The default setting is 0dB.

1.To change the setting, select MIC GAIN.

2.Then, turn the SELECT control to scroll between -15dB and +15dB and then tap SELECT.

3.Double-tap the SELECT control to return to the previous menu level when finished. Or, press and hold the SELECT control for two seconds to exit menu mode.

Remember to save you changes if you want them retained for future use. See “Menus, SERVICE, SAVE CFG” on page 44..

Menus, SERVICE, MOD ASGN

NOTE: The information in this section applies when any of the following occurs:

The call waiting window displays MD1 at power-up

Key modules have been replaced

EKP Expansion Panels and/or LCP Level Control Panels are being used with a KP-12

A group of 4 keys do not operate correctly

When any of these situations occurs, you may have to reprogram MOD numbers as described in the following paragraphs.

How MODS Work

The keypanels, expansion panels and level control panels in this product line all use a system of MODS. MODS are simply groups of 4 consecutive intercom system keys and their associated displays (or groups of 4 control knobs in the case of LCPs). Since the DKP-8 and DKP-12 keypanels are typically used without expansion panels and level control panels, only a few MODS are used. If you need to assign MODS on a DKP keypanel, simply refer to the “Procedure to Assign MODS”, and set MODS 1 and 2 (DKP-8) or 1-3 (DKP-12) as summarized in Table 4 . The KP-12 keypanel, on the other hand, can be used with various combinations of expansion panels and level control panels. In this case, you need to program each group of four keys on the KP-12 and any connected EKPs to a unique MOD number. And, if you are using LCP level control panels to adjust lis- ten levels for intercom keys, you want to make sure that the MOD numbers for the level control knobs match the MOD num- bers for the intercom keys. The LCP MOD numbers cannot be set from the KP-12. They must be set by replacing the internal read-only memory. (ROM) in the LCP. Table 4 shows the default MOD numbers that are programmed into the various LCPs. Note, the default settings for LCPs will work when one LCP-12 is used with a KP-12, or when one LCP-16 or LCP-20 is being used with one EKP-16 or EKP-20. However, there are two situations where you will need to change the ROM in and LCP:

when you want to use an LCP-12 with and EKP-12

when you are connecting more than one EKP, and you want to use LCPs with each EKP. If you need to change MOD numbers in an LCP, contact you intercom dealer for assistance.

TABLE 4. Default Module Number Assignments

Keypanel/LCP-12 Default MODE Assignments

MOD 1

Keys 1-4

MOD 2

Keys 5-8

MOD 3

Keys 9-12 (not used for DKP-8

 

Keys 13-16 (Do not assign this MOD. It is used exclusively

MOD 4

for the SELECT control and call waiting display on

 

keypanels.)

EKP-12 Default MOD Assignments

MOD 5

Keys 17-20

40

Image 46
Contents User Instructions This package should include the following Contents Contents Contents Contents Read ME First Page Menu List for DKP-8, DKP-12, and KP-12 Keypanels Menu Item DescriptionMenu List for DKP-8, DKP-12, and KP-12 Keypanels DKP-8 Keypanel Reference View Push-button version shown DKP-12 Keypanel Reference View Push-button version shown KP-12 Keypanel Reference View Push-button version shown Menu List for DKP-8, DKP-12, and KP-12 Keypanels Applying Power Power-Up and Initial SettingsMD1, Key Type and Set Addr Messages Power-Up Indications Basic Intercom Operation Talk and Listen IndicatorsKeys and Displays Flashing Call Indicator Headset/Speaker/PRGM Selection and Volume AdjustmentCopy Call Waiting All-Purpose Phone Key Operation Telephone OperationManual Dialing with an All-Purpose Phone Key Dialing an Autodial Number Using an All-Purpose Phone Key Dialing a Number Using a Redial or Autodial KeyGeneral Description Using the Top-Level MenuTop Level Menu, - - Clear call waiting Top Menu Level, Call List Names Top Level Menu, DisplayTop Level Menu, Display, KEY Type Top Level Menu, Display, KEY IcomTop Level Menu, Display, Level Top Level Menu, Display, Port Num Top Level Menu, Display, ListenTop Level Menu, Display, Page Use Top Level Menu, Display, SoloTop Level Menu, Lists Top Level Menu, Key ListTop Level Menu, Level Top Level Menu, Lists, IcomTop Level Menu, Lists, IFB Top Level Menu, Lists, P-P Point-to-PointTop Level Menu, Lists, Ifsl Top Level Menu, Lists, RLY Relays Top Level Menu, Lists, ISOTop Level Menu, Lists, Spcl Special Lists Top Level Menu, Top Level Menu, MenusTop Level Menu, Lists, UPL Top Level Menu, TGL Lisn Toggle Listen ON/OFF Using the Top-Level Menu Menu Mode Select Control Operation in Menu ModeKeypanel Menus in Menu Mode Menus, Autodial for KP-12/DKP-12 OnlyMenus, KEY ASGN, Autodial For KP-12, DKP-12 Only Menus, KEY AsgnMenus, KEY ASGN, General Description Menus, KEY ASGN, AutofuncMenus, KEY ASGN, Clear Menus, KEY ASGN, CopyMenus, KEY ASGN, Lists General DescriptionMenus, KEY ASGN, LISTS, PL Party Line Menus, KEY ASGN, LISTS, IFBMenus, KEY ASGN, LISTS, Icom Tap SelectMenus, KEY ASGN, LISTS, ISO Menus, KEY ASGN, LISTS, IfslMenus, KEY ASGN, LISTS, P-P Point-to-Point Menus, KEY ASGN, LISTS, RLY Relays Menus, KEY ASGN, LISTS, Spcl Special ListsMenus, KEY ASGN, Phone For KP-12, DKP-12 Only Menus, KEY ASGN, Local I/O For KP-12 OnlyMenus, KEY ASGN, LISTS, UPL Menus, KEY ASGN, Redial For KP-12, DKP-12 Only Menus, KEY ASGN, UPLMenus, KEY OPT, BTN Lock Button Lock Menus, Key Opt MenuMenus, KEY OPT, Chime Menus, KEY OPT, Exclusive Menus, KEY OPT, CLR OPTMenus, KEY OPT, Copy Menus, KEY OPT, GroupMenus, KEY OPT, Latching Menus, KEY OPT, SoloMenus, SERVICE, Foot SW with GPI module only Menus, Service MenuMenus, SERVICE, Dimmer Menus, SERVICE, KEY TypeSelect MENUS, SERVICE, Lock Menus, SERVICE, MIC CtrlMenus, SERVICE, MIC Comp Select SERVICE, UnlockMenus, SERVICE, MOD Asgn Menus, SERVICE, MIC GainHow Mods Work Procedure to Assign Mods Menus, SERVICE, Mute LVL Using Multiple Expansion Panels KP-12 OnlyMenus, SERVICE, OPTO-ISO KP-12 with GPI Module Only Call waiting window displays OPT1Menus, SERVICE, Save CFG Menus, SERVICE, OUT CtrlMenus, SERVICE, Reset Menus, SERVICE, SET AddrMenus, SERVICE, Tally Menus, SERVICE, SidetoneMenus, SERVICE, Test PNL Menus, SERVICE, Tone Settings for Intercom Port Numbers 596 KP-12 Audio Transmit Board Connections Page Replacing the KP-12 Power Supply Replacing the KP-12 Power SupplyCN2 Page Portland Avenue South Burnsville, MN 55337 U.S.A