Aiphone JK-1MED Wiring, Insert wires securely into each terminal as shown, 230V AC N

Page 4

3 WIRING

Insert wires securely into each terminal as shown.

English

DOOR Video door station

 

 

 

JK-DA

 

 

 

Français

JK-DV

JK-DVF

 

A1

A2

 

 

 

 

 

2

 

 

 

NP

 

Nederlands

 

 

 

Optional call extension speaker

 

IER-2

 

 

 

OP

1 E

 

 

 

 

2

 

IER-2

 

NP

 

 

 

 

Presence of sound from IER-2

 

 

Item

 

Sound

Chime tone from door station (8-1)

Alarm sound during external sensor

input (8-15)

 

 

 

 

 

Audio during instant voice call (8-1)

Chime tone during room-to-room

communication (8-4)

 

 

 

Door release

 

 

 

JK-1MEDMaster monitor station

OPTION

CONNECTOR

 

2

 

 

NP

2

P

2

P

 

 

-+

DC 18 V

Power supply

 

PS-1810DIN/

PS-1820

NP: Non-polarized

P: Polarized

PS-1820DIN

 

 

 

230V AC N

 

 

L

 

 

IN 230V~ 50/60Hz NL

 

 

1A - +

 

 

-

100V - 240V -

18V DC

+

2 A

18V DC 1A (PS-1810DIN)

50/60 Hz

 

18V DC 2A (PS-1820DIN)

 

 

An EL-12S (AC 12 V 0.125 A, DC 12 V 0.2 A) or equivalent part and a separate AC transformer are required. Run separate cables for audio/video and door release.

Door release contact: AC/DC 24 V, 0.5 A (Minimum Contact : 100 mV DC, 0.1 mA) (N/O dry closure contact L, L).

OP

2

NP

EL-12S

AC transformer

- 4 -

Image 4
Contents JK-1MED Monitor-hoofdpostPrecautions Package ContentsWire the units from station-to-station daisy-chained Wiring method, wiring distanceCable Wiring Insert wires securely into each terminal as shown230V AC N AC transformerStart signal only detection method Dry closure contactExternal sensor input Detection MS or more Confirmation timeBack wiring Surface wiringMounting NamesSetting UP Setting screens and display methodsManual, an explanation is given using REC button ※ Setting can also be done by pressing ZOOM/WIDE buttonInitial Setting screen LED red will flash as a notification. Reset the timeAfter performing steps 1 and 2 in -1, select Language After performing steps 1 and 2 in -1, select DATE/TIMESetting communication time Previous screenRestore default setting Automatic night volume adjustmentSetting picture recording Press-to-talk setting2nd shot 4th shot 5th shot 3rd shot 6th shot Answering a door call HANDS-FREE mode, PTT mode PTT modeOperations Instant voice call functionWIDE/ZOOM switching Press ZOOM/WIDE button when a picture is displayedEntrance monitoring Room-to-room communicationWhen communication ends, the illuminator LED will go out Pan/tilt operationZoom Picture Pre-set Night illuminationAutomatic recording Backlight adjustment, Night sensitivity adjustmentManual recording Play recorded picture Save recorded pictureImages can be saved from the recorded images maximum Images. Saved pictures are not overwrittenWarranty