Aiphone GH series operation manual Gh-Da

Page 14

3-2

1

GH-DA

CN

1

ON

 

3

4

 

 

2

 

 

1

 

 

 

CN2

 

 

 

 

1

0

2

GH-DA

CN2

GH-SW

CN1

3-3

1

CN3

GH-VA

GH-DA

CN1

2

GH-VA GH-NS

GH-DA

GH-10K

GH-AD

GF-BP

GF-C

GF-3B GF-3B

GH-DAGH-NS

CN1

CN2

CN1CN3

CN100 CN2

GH-ADGH-10K

3

GF-C

 

 

 

GH-DA

 

GF-3B

GF-3B

GF-3B

3

CN2

CN1

CN1

CN2

CN2

CN1

CN1

CN2

CN2

CN1

4

5

GH-DA

CN

1

ON

 

3

4

 

 

1

2

 

 

 

CN2

 

 

 

 

1

0

Mounting the Entrance Station (3)

1.Example of interconnection of modules.

2.Use GF-C to connect to the name scrolling module.

3.To position the speech module in the center row, run GF-C through the joint pipe in advance.

Mounting the Entrance Station (2)

1.Remove the terminal cover.

2.From the speech module to the next module, insert the attached connector into the socket. Make sure to run the cable under the terminal cover for protection.

3.Connect the connectors between the modules with cables.

4.Run the connection cable through the joint pipe (which you should have made open in advance) and connect CN1 of GH- SW to the next row.

5.Put back the terminal cover.

- 14 -

Image 14
Contents GH Series Precautions Names Entrance Station Standard system Wiring System Configurations Standard System Configuration Diagram #1 b Expanded System Configuration Diagram Wiring DistanceUnit Unit Entrance StationCombination Example for Entrance Station Unit Bus Control Unit and OthersResidential Station Security Guard StationMounting Mounting the Entrance StationGH-DA Bus Control Unit and Power Supply Adapter Optional Handset GH-1AD GH-1KDSecurity Guard Station Mounted on Wall Wiring VR1Standard System 2 Station-to-Station Wiring Standard SystemGH-1MD Standard System 2 Homerun Wiring NPNon-polarizedGH-VBX Expanded System External Relay ConnectionEntrance Station Names Entrance Station Names Residential StationGH-10K Residential station GH-1AD, GH-1KDNames Security Guard Station Residential station GH-1MDAdjusting the Camera Angle Entering Names and AddressesMaking Adjustments with the Mounting Gauge Setting up the System Default setting of ∗1111 Programming GH-NSMenu Program Mode GH-NS Setting UP Security Guard Station Select Menu & QuitProgramming GH-MK Menu Program Mode GH-MK Calling a Residential Station 10-1Operations Entrance Station Calling the Security Guard Station 10-210-3 Door ReleaseCall from the Doorbell Button Individual Entrance Door 11-1 11-2Responding to a Call Turning on the Entrance Light 11-311-4 Automatic Entry Doctor Call Option 11-511-6 Entrance Monitoring Emergency Alarm11-7 11-8 Responding to a Call from an Entrance Station 12-112-2 Responding to a Call from a Residential Station12-3 12-4 Calling a Entrance StationCalling Another Security Guard Station 12-512-6 Emergency Call12-9 12-712-8 Specifications Technical Precautions SpecificationsTechnical precautions Warranty