Aiphone GH series operation manual Programming GH-MK

Page 33

9-1

Programming (GH-MK)

Make sure that all units are installed and wired properly. Turn on the power switch to GH-BC. Program the resident information (names and room numbers) in advance.

a. Programming with a PC

You can use a PC to enter data and write in or change resident names.

Use the connection cable that comes with GH-MK to connect your PC to GH-MK.

In your PC, install the setup tool program from the CD that comes with GH-BC.

For information on how to use the setup tool, see the text (.txt) file that is installed in the same folder as the setup tool (.exe).

b. Programming with GH-MK

Confirm that "AIPHONE" is shown on the Display, indicating that the system is in standby mode.

First, set the system to program mode. (For details, see 9-2.) Before you begin programming, we recommend that you

register a new exclusive ID code for yourself so that the system is not accessed by others. (For details, see 9-2.)

1. Menu 5: Programming

2. Lift the handset (security guard station).

3. Press the talk button on the first residential station. The corresponding communication channel will be established.

4. Use the search button to display the assigned name and then press the call button.

5. If an electronic beep is emitted once, the residential station has been set up successfully. (If an electronic sound is emitted twice, it is for the second residential station.) Press the talk button to end the communication channel. Go to the location of each residential station and program them one by one in accordance with the programming procedures.

6. Replace the handset (security guard station).

1.If you have forgotten your ID code, set the switch (#1) to

ON for approximately 2 seconds. The ID code will be reset to the default setting of "1111".

2.While data is being entered into the system, the entire system cannot function (including emergency calls).

NOTES: If you attempt to setup a fifth residential station when four residential stations have already been established, an alarm beep will be emitted. To cancel the communication link,display the assigned name and press the call button for at least 3 seconds. A continuous beep will be emitted to verify the communication link has been cleared.

- 33 -

Image 33
Contents GH Series Precautions Names Entrance Station Standard system Wiring System Configurations Standard System Configuration Diagram #1 b Wiring Distance Expanded System Configuration DiagramUnit Entrance Station UnitUnit Bus Control Unit and Others Combination Example for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA Bus Control Unit and Power Supply Adapter GH-1AD GH-1KD Optional HandsetSecurity Guard Station Mounted on Wall VR1 WiringStandard System Standard System 2 Station-to-Station WiringGH-1MD NPNon-polarized Standard System 2 Homerun WiringGH-VBX External Relay Connection Expanded SystemGH-10K Names Entrance Station Names Residential StationEntrance Station Residential station GH-1AD, GH-1KDResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Default setting of ∗1111 Menu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK 10-1 Operations Entrance StationCalling a Residential Station 10-3 10-2Calling the Security Guard Station Door Release11-1 11-2 Responding to a CallCall from the Doorbell Button Individual Entrance Door 11-3 11-4Turning on the Entrance Light 11-5 11-6Automatic Entry Doctor Call Option Emergency Alarm 11-7 11-8Entrance Monitoring 12-2 12-1Responding to a Call from an Entrance Station Responding to a Call from a Residential StationCalling a Entrance Station 12-3 12-412-6 12-5Calling Another Security Guard Station Emergency Call12-7 12-812-9 Technical Precautions Specifications Technical precautionsSpecifications Warranty