9-2

Program Mode (GH-MK)

1.Menu 1: Select language

Choose language to be displayed on GH-MK.

2.Menu 2: Change ID code

Enter new ID code starting with "", then 4-digit number. (Example: 1234)

3.Menu 3: Write in resident information Register room #s and resident names. Enter room #s using 1 to 6-digit characters. Enter resident name (up to 16 characters).

4.Menu 4: Set input timeout timer

Operation Timer: If the operation panel is not operated for a certain period of time, the system returns to standby mode. Programmable from 15 to 99 seconds.

Program Timer: If, in Resident Programming mode, the operation panel is not operated for a certain period of time, it automatically cancels the programming mode. Programmable from 30 to 99 seconds.

Call Time: Call from Entrance panel expires in a certain period of time. Programmable from 30 to 99 seconds.

5.Menu 5: Programming

For the programming procedures, see 9-1.

6. Menu 6: Transfer link information

7. Menu 7: Link check (for maintenance purposes)

An electronic sound will be emitted once if link is normal. If the link is abnormal, an alarm sound will be emitted.

- 35 -

Image 35
Contents GH Series Precautions Names Entrance Station Standard system Wiring System Configurations Standard System Configuration Diagram #1 b Wiring Distance Expanded System Configuration DiagramUnit Entrance Station UnitUnit Bus Control Unit and Others Combination Example for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA Bus Control Unit and Power Supply Adapter GH-1AD GH-1KD Optional HandsetSecurity Guard Station Mounted on Wall VR1 WiringStandard System Standard System 2 Station-to-Station WiringGH-1MD NPNon-polarized Standard System 2 Homerun WiringGH-VBX External Relay Connection Expanded SystemResidential station GH-1AD, GH-1KD Names Entrance Station Names Residential StationGH-10K Entrance StationResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Default setting of ∗1111Menu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK Calling a Residential Station 10-1Operations Entrance Station Door Release 10-210-3 Calling the Security Guard StationCall from the Doorbell Button Individual Entrance Door 11-1 11-2Responding to a Call Turning on the Entrance Light 11-311-4 Automatic Entry Doctor Call Option 11-511-6 Entrance Monitoring Emergency Alarm11-7 11-8 Responding to a Call from a Residential Station 12-112-2 Responding to a Call from an Entrance StationCalling a Entrance Station 12-3 12-4Emergency Call 12-512-6 Calling Another Security Guard Station12-9 12-712-8 Specifications Technical Precautions SpecificationsTechnical precautions Warranty