Aiphone GH series operation manual Expanded System Configuration Diagram, Wiring Distance

Page 9

1-2

Expanded System Configuration Diagram

1.Common trunk line #1, 2

2.Sub trunk line #1 - 4

Sub trunk line #2 - #4 are the same as #1. Maximum 125 units per sub trunk line.

(1)Audio signal line

(2)Video signal line

(3)Power supply line

a.Entrance station (For details, see 2-1 and 2-2)

b.Bus control unit

c.Residential station (For details, see 2-4): Station-to-station wiring (For details, see 1-1)

d.Residential station (For details, see 2-4): Homerun wiring (For details, see 1-1)

Do not mix station-to-station wiring and homerun wiring.

e.Security Guard Station

f.Expanded bus control unit

[1]Expanded video bus control unit GH-VBX

[2]Expanded bus control unit GH-BCX

[3]Distribution terminal (junction): sold separately

[4]Power supply adapter PS-2410LC, PS-2410LD, PS-2410DIN

 

Capacity

Entrance Station

Maximum 16 stations

 

(up to 3 stations per trunk)

 

 

Residential stations

Maximum 125 stations

per sub trunk line

(up to 25 stations per trunk)

 

 

Residential Station

Maximum 500 stations

Security Guard Station

Maximum 4 stations

Residential stations

Maximum 4 stations

in the same residence

(up to 2 monitor stations)

1-3

Wiring Distance

DP = Distribution Point

Diameter of wires

0.65 mm

0.8 mm

1.0 mm

(22 AWG)

(20 AWG)

(18 AWG)

 

GH-BC - DP

-

5 m

-

 

 

(16')

 

DP - GH-DA

-

300 m

-

 

 

(980')

 

GH-VBC - GH-VA

150 m

300 m

-

 

(490')

(980')

 

GH-MK - DP

-

300 m

-

 

 

(980')

 

DP - farthest residential station

-

300 m

-

(R1-R2)

 

(980')

 

(Includes system with GH-4Z)

 

 

 

 

 

 

 

GH-VBC - farthest residential station

100 m

150 m

-

(1 monitor units/residence)

(330')

(500')

 

(Includes system with GH-4Z)

 

 

 

GH-VBC - farthest residential station

50 m

100 m

150 m

(2 monitor units/residence)

(165')

(330')

(500')

(Includes system with GH-4Z)

 

 

 

GH-VBC (SW: STD)

100 m

150 m

-

- GH-VBC (SW: EXP)

(330')

(500')

 

GH-BC - power supply

-

5 m

5 m

 

 

(16')

(16')

 

 

 

 

GH-VBC - power supply

-

5 m

5 m

 

 

(16')

(16')

GH-NS - power supply

-

300 m

300 m

 

 

(980')

(980')

GH-MK - power supply

-

300 m

300 m

 

 

(980')

(980')

Common trunk line

-

2500 m

-

(Maximum 2 trunk lines)

 

(8200')

 

total wiring length per trunk line

 

 

 

Sub trunk line

-

2500 m

-

(Maximum 4 trunk lines)

 

(8200')

 

total wiring length per trunk line

 

 

 

GH-BC - GH-BCX

-

5 m

-

 

 

(16')

 

GH-VBC -GH-VBX

-

150 m

-

 

 

(500')

 

GH-DA - GH-BCX

-

300 m

-

 

 

(980')

 

GH-VA - GH-VBX

150 m

300 m

-

 

(500')

(980')

 

GH-BCX - farthest residential station

-

300 m

-

(R1-R2)

 

(980')

 

(Includes system with GH-4Z)

 

 

 

GH-VBX - farthest residential station

100 m

150 m

-

(1 monitor units/residence)

(330')

(500')

 

(Includes system with GH-4Z)

 

 

 

 

 

 

 

GH-VBX - farthest residential station

50 m

100 m

150 m

(2 monitor units/residence)

(165')

(330')

(500')

(Includes system with GH-4Z)

 

 

 

 

 

 

 

- 9 -

Image 9
Contents GH Series Precautions Names Entrance Station Standard system Wiring System Configurations Standard System Configuration Diagram #1 b Wiring Distance Expanded System Configuration DiagramUnit Entrance Station UnitUnit Bus Control Unit and Others Combination Example for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA Bus Control Unit and Power Supply Adapter GH-1AD GH-1KD Optional HandsetSecurity Guard Station Mounted on Wall VR1 WiringStandard System Standard System 2 Station-to-Station WiringGH-1MD NPNon-polarized Standard System 2 Homerun WiringGH-VBX External Relay Connection Expanded SystemGH-10K Names Entrance Station Names Residential StationEntrance Station Residential station GH-1AD, GH-1KDResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Default setting of ∗1111Menu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK 10-1 Operations Entrance StationCalling a Residential Station 10-3 10-2Calling the Security Guard Station Door Release11-1 11-2 Responding to a CallCall from the Doorbell Button Individual Entrance Door 11-3 11-4Turning on the Entrance Light 11-5 11-6Automatic Entry Doctor Call Option Emergency Alarm 11-7 11-8Entrance Monitoring 12-2 12-1Responding to a Call from an Entrance Station Responding to a Call from a Residential StationCalling a Entrance Station 12-3 12-412-6 12-5Calling Another Security Guard Station Emergency Call12-7 12-812-9 Technical Precautions Specifications Technical precautionsSpecifications Warranty