Aiphone 0207 AIC operation manual Standard System 2 Station-to-Station Wiring

Page 19

4-2

 

 

 

 

 

 

 

 

 

 

 

a

 

b

c

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1P

 

 

 

 

 

 

 

 

 

 

NP

 

GH-1AD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN OUT

 

 

 

 

 

 

 

 

 

 

R1R2 R1R2 C CE

K KE

 

 

 

 

 

 

 

 

1P

 

 

 

 

 

 

 

 

 

 

NP

 

 

 

 

 

 

 

 

 

 

R1, R2

 

 

 

 

 

 

 

 

SW1

 

 

 

 

 

 

 

 

 

c

A

B

 

 

 

 

 

 

 

 

 

 

 

 

GH-1KD

 

 

 

 

 

 

 

 

 

 

 

 

IN

OUT

IN OUT

 

 

 

 

 

 

 

 

B1B2 B1B2

R1R2 R1R2 C CE

K KE

 

 

 

 

 

 

 

1P

1P

[2]

 

 

 

 

 

 

 

NP

NP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

KE

 

 

 

 

 

 

SW1

B

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

GH-1KD

 

 

 

 

IN

OUT

IN OUT

 

 

 

 

 

 

 

 

B1B2 B1 B2

R1 R2 R1 R2 C CE

K KE

 

 

 

 

 

 

 

 

 

 

[2]

 

 

 

 

 

 

[1]

SW1

 

1P

1P

 

 

 

 

 

 

GH-1KD

B

 

 

 

 

 

 

A

NP

NP

 

 

 

 

 

 

 

 

 

 

 

SW1 A B Do not

remove the

wires (For end users)

 

 

 

 

 

 

IN

OUT

 

0.65 10 9

 

 

 

 

 

 

R1

R2

R1

R2

C CE

K KE

 

IN

OUT

IN OUT

 

 

 

 

 

 

 

 

B1B2 B1 B2

R1 R2 R1 R2 C CE

K KE

 

 

 

 

 

 

GH-VBC

 

 

 

[2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b GH-BC

1P

 

 

 

 

 

 

 

 

 

NP

 

 

[3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GH-RY

 

 

 

 

1P

 

 

 

 

 

 

 

 

 

 

NP

 

 

 

 

 

 

 

 

 

 

 

[4]

 

B

AC

 

 

 

 

 

4-1

Standard System (1)

[1]Entrance Station

[2]Door release timer (set to "M" at time of shipment)

Set the duration for the door release function when the door release button is pressed.

[0.5] - [20]: 0.5 secs - 20 secs

[20]- [M]: Activates while the button is pressed.

[3] Setting switch (GH-DA/A)

SW2: 1: Setting switch for camera entrance station monitoring function (set to OFF at time of shipment)

ON (Up): Monitored.

OFF (Down): Skipped at time of entrance station monitoring.

SW2: 2 - 4: Entrance station number setting switch (set to #1 at time of shipment)

When installing multiple entrance stations, make sure to set the GH-DA/A ID numbers (SW2).

[4]External signaling relay GH-RY For details, see 4-5.

[5]Door release relay contact

Less than AC/DC 24 V, 4 A (resistance load) PT: AC Transformer

[6]Security guard station GH-MK

[7]Setting switch (GH-MK)

SW1: 1: Password reset switch

Set the password reset switch to ON for 2 seconds or more during standby will reset the password (set to "1111" at time of shipment).

SW1: 2, 3: Unused switch

SW1: 4: Security guard station number setting switch (set to #1 at time of shipment)

When installing two security guard stations, make sure to set the ID numbers (SW1).

[8]Doorbell button

[9]Power supply PS-2410LC, PS-2410LD, PS-2410DIN

[10]Video Bus control unit GH-VBC (SW: STD)

[11]Video Bus control unit GH-VBC (SW: EXP)

To use GH-VBC as an extension adaptor, set the setting switch to "EXP". Connect only "IN1" terminal at input side.

[12]Bus control unit GH-BC

[13]Distribution terminal (junction): Not included

NP: Non-polarized

4-2

Standard System (2) Station-to-Station Wiring

[1] Residential station GH-1KD, GH-1AD

There can be a maximum of 25 stations per trunk.

For the terminating residential station GH-1KD, set the setting switch (SW1) to "A".

[2] Short lead

To use the emergency alarm switch (see 11-7 for details),

disconnect the short lead and connect the switch.

[3]External signaling relay GH-RY For details, see 4-5.

The separate option connecter is required. [4] Doorbell button

1. Do not mix station-to-station wiring with homerun wiring. 2. Station-to-station wiring is not possible for GH-1MD.

NP: Non-polarized

- 19 -

Image 19
Contents GH Series Precautions PS24 System ConfigurationStandard System Configuration System Configuration PS24 Wiring Distance Expanded System Configuration DiagramUnit Entrance Station ComponentsUnit Bus Control Unit and Others Combination Examples for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA/A Bus Control Unit and Power Supply GH-1AD GH-1KD Optional HandsetSecurity Guard Station Wall-mounting Standard system WiringHomerun wiring with GH-4Z Station-to-station wiring SW1 Standard System Standard System 2 Station-to-Station WiringGH-1MD Standard System 3 Homerun Wiring Expanded system SW1 PS24 Expanded System External Signaling Relay ConnectionResidential station GH-1AD, GH-1KD Names Entrance Station Names Residential StationGH-10K Entrance StationResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Enter Program ModeMenu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK Operations Entrance Station 10-1Calling a Residential Station 11-1 10-210-3 11-3 211-6 11-2 11-511-4 11-7 11-8 Emergency AlarmMonitoring Entrance Stations Replying to a Call from a Residential Station 12-112-2 Replying to a Call from an Entrance StationCalling an Entrance Station 12-3 12-4Calling Another Security Guard Station 12-512-6 Emergency Call12-8 12-712-9 Technical precautions Technical Precautions SpecificationsSpecifications Warranty