Aiphone 0207 AIC operation manual Programming GH-MK

Page 35

9-1

Programming (GH-MK)

Make sure that all units are installed and wired properly. Turn on the power switch to GH-BC. Program the resident information (names and room numbers) in advance.

a. Programming with a PC

You can use a PC to enter data and write in or change resident names.

Use the connection cable that comes with GH-MK to connect your PC to GH-MK.

In your PC, install the setup tool program from the CD that comes with GH-BC.

For information on how to use the setup tool, see the text (.txt) file that is installed in the same folder as the setup tool (.exe). Save programmed data and resident information data to your PC is recommended.

b. Programming with GH-MK

Confirm that "AIPHONE" is shown on the Display, indicating that the system is in standby mode.

First, set the system to program mode. (For details, see 9-2.) Before you begin programming, we recommend that you

register a new exclusive ID code for yourself so that the system is not accessed by others. (For details, see 9-2.)

1. Menu 5: Programming

2. Lift the handset (security guard station).

3. Press the talk button on the first residential station. The corresponding communication channel will be established. For other GH-MK, lift the handset.

4. Use the search button to display the assigned name and then press the call button.

5. If an electronic beep is emitted once, the residential station has been set up successfully. (If an electronic sound is emitted twice, it is for the second residential station.) Press the talk button to end the communication channel. Go to the location of each residential station and program them one by one in accordance with the programming procedures.

6. Replace the handset (security guard station).

1. If you have forgotten your ID code, set the switch (#1) to ON for approximately 2 seconds. The ID code will be reset to the default setting of "1111".

2. While data is being entered into the system, the entire system cannot function (including emergency calls).

NOTE: If you attempt to setup a fifth residential station when four residential stations have already been established, an alarm beep will be emitted. To cancel the communication link, display the assigned name and press the call button for at least 3 seconds. A continuous beep will be emitted to verify the communication link has been cleared.

- 35 -

Image 35
Contents GH Series Precautions PS24 System ConfigurationStandard System Configuration System Configuration PS24 Wiring Distance Expanded System Configuration DiagramUnit Entrance Station ComponentsUnit Bus Control Unit and Others Combination Examples for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA/A Bus Control Unit and Power Supply GH-1AD GH-1KD Optional HandsetSecurity Guard Station Wall-mounting Standard system WiringHomerun wiring with GH-4Z Station-to-station wiring SW1 Standard System Standard System 2 Station-to-Station WiringGH-1MD Standard System 3 Homerun Wiring Expanded system SW1 PS24 Expanded System External Signaling Relay ConnectionResidential station GH-1AD, GH-1KD Names Entrance Station Names Residential StationGH-10K Entrance StationResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Enter Program ModeMenu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK Calling a Residential Station 10-1Operations Entrance Station 10-3 10-211-1 11-4 11-2 11-511-3 211-6 Monitoring Entrance Stations Emergency Alarm11-7 11-8 Replying to a Call from a Residential Station 12-112-2 Replying to a Call from an Entrance StationCalling an Entrance Station 12-3 12-4Calling Another Security Guard Station 12-512-6 Emergency Call12-9 12-712-8 Specifications Technical Precautions SpecificationsTechnical precautions Warranty