Aiphone 0207 AIC operation manual Technical Precautions Specifications, Technical precautions

Page 46
160 (W) x 210 (H) x 55.5 (D) mm (6-5/16 x 8-1/4 x 2-3/16 inch)
125 (W) x 175 (H) x 32 (D) mm (4-15/16 x 6-7/8 x 1-1/4 inch)
125 (W) x 175 (H) x 32 (D) mm (4-15/16 x 6-7/8 x 1-1/4 inch)
122.5 (W) x 108.5 (H) x 61 (D) mm (4-13/16 x 4-1/4 x 2-3/8 inch)
122.5 (W) x 108.5 (H) x 61 (D) mm (4-13/16 x 4-1/4 x 2-3/8 inch)
122.5 (W) x 108.5 (H) x 61 (D) mm (4-13/16 x 4-1/4 x 2-3/8 inch)
215 (W) x 210 (H) x 69 (D) mm (8-7/16 x 8-1/4 x 2-3/4 inch)
210 (W) x 108.5 (H) x 61 (D) mm (8-1/4 x 4-1/4 x 2-3/8 inch)
210 (W) x 108.5 (H) x 61 (D) mm (8-1/4 x 4-1/4 x 2-3/8 inch)
270 (W) x 225 (H) x 16 (D) mm (10-5/8 x 8-7/8 x 5/8 inch) (Box depth: 44mm (1-3/4"))
135 (W) x 320 (H) x 16 (D) mm (5-5/16 x 12-5/8 x 5/8 inch) (Box depth: 44mm (1-3/4"))

13 TECHNICAL PRECAUTIONS

14 SPECIFICATIONS

Technical precautions

-10 °C to 60 °C

• Operating temperature:

Entrance Station:

 

 

(14 °F to 140 °F)

 

Residential Station:

0 °C to 40 °C

 

 

(32 °F to 104 °F)

 

Security Guard Station:0 °C to 40 °C

 

 

(32 °F to 104 °F)

 

Control Unit:

0 °C to 40 °C

 

 

(32 °F to 104 °F)

• Mounting location:

Do not install the entrance station in a

 

place where there would be a bright

 

light behind a visitor (or where there

 

would be a bright background) or in a

 

place where the camera lens would be

 

directly exposed to sunlight or a bright

 

light.

 

• Rain hood (option):

Although the entrance station is

 

weather resistant, it is recommended

 

that it not be directly exposed to

 

weather conditions. The rain hood (GF-

H) can be installed to protect the entrance station from rainfall.

Post-replacement setup: After all wiring is completed and the residential station has been replaced, turn off the power to GH-BC temporarily and then turn it back on. Next, reprogram the relevant residential station.

• Operation:

When an entrance station is calling a

 

residential station, the call tone from

 

the doorbell button will not sound.

• Cleaning:

Clean the units with a soft cloth

 

dampened with a neutral household

 

cleanser. Never use an abrasive cleanser

 

or cloth.

• Repair requests:

When units do not operate properly,

 

request a qualified technician for repairs.

Specifications

Power supply:

DC 24V supplied by PS-2410LC, PS-2410LD, PS-2410DIN (for each GH-BC, GH-VBC, GH-NS/10K, GH-MK, GH-BCX/A)

Current consumption:

GH-BC: 0.9 A, GH-VBC: 0.9 A, GH-NS: 0.13 A,

GH-MK: 0.18 A, GH-BCX/A: 0.45 A

Call tone:

There are three different types of call tones:a call tone for the entrance station, a call tone for the security guard station and a call tone for the doorbell button.

Communication path: Single path, non-open

Communication:

Voice-actuated communication (or press-to-talk communication)

Door release:

Connecting terminals: Between ELM-ELC (N/O) and ELB- ELC (N/C)

Specifications: less than 4A (resistance load), AC/DC 24V, dry closure contact for door release

Wiring: Two single-pair cable

Type of cables:

Pair cable (solid wire not stranded), polyethylene insulated, diameter 0.65 ~ 1.0 mm

Dimensions:

GH-1MD:

GH-1AD:

GH-1KD:

GH-BC:

GH-VBC:

GH-4Z:

GH-MK:

GH-BCX/A:

GH-VBX:

Entrance Station

2 module, 2 row panel:

3 module, 1 row panel:

Weight:

GH-1MD: Approx. 980 g (2.2 lbs.)

GH-1AD: Approx. 330 g (0.7 lbs.)

GH-1KD: Approx. 400 g (0.9 lbs.)

GH-BC: Approx. 450 g (1.0 lbs.)

GH-VBC: Approx. 250 g (0.6 lbs.)

GH-4Z: Approx. 190 g (0.4 lbs.)

GH-MK: Approx. 900 g (2.0 lbs.)

GH-BCX/A: Approx. 370 g (0.8 lbs.)

GH-VBX: Approx. 370 g (0.8 lbs.)

- 46 -

Image 46
Contents GH Series Precautions System Configuration PS24Standard System Configuration System Configuration PS24 Expanded System Configuration Diagram Wiring DistanceComponents Unit Entrance StationCombination Examples for Entrance Station Unit Bus Control Unit and OthersResidential Station Security Guard StationMounting Mounting the Entrance StationGH-DA/A Bus Control Unit and Power Supply Optional Handset GH-1AD GH-1KDSecurity Guard Station Wall-mounting Wiring Standard systemHomerun wiring with GH-4Z Station-to-station wiring SW1 Standard System 2 Station-to-Station Wiring Standard SystemGH-1MD Standard System 3 Homerun Wiring Expanded system SW1 PS24 External Signaling Relay Connection Expanded SystemEntrance Station Names Entrance Station Names Residential StationGH-10K Residential station GH-1AD, GH-1KDNames Security Guard Station Residential station GH-1MDAdjusting the Camera Angle Entering Names and AddressesMaking Adjustments with the Mounting Gauge Setting up the System Enter Program Mode Programming GH-NSMenu Program Mode GH-NS Setting UP Security Guard Station Select Menu & QuitProgramming GH-MK Menu Program Mode GH-MK Operations Entrance Station 10-1Calling a Residential Station 11-1 10-210-3 11-3 211-6 11-2 11-511-4 11-7 11-8 Emergency AlarmMonitoring Entrance Stations Replying to a Call from an Entrance Station 12-112-2 Replying to a Call from a Residential Station12-3 12-4 Calling an Entrance StationEmergency Call 12-512-6 Calling Another Security Guard Station12-8 12-712-9 Technical precautions Technical Precautions SpecificationsSpecifications Warranty