Aiphone 0207 AIC operation manual Expanded System Configuration Diagram, Wiring Distance

Page 7

1-2

Expanded System Configuration Diagram

1.Common trunk line #1, 2

2.Sub trunk line #1 - 4

Sub trunk line #2 - #4 are the same as #1. Maximum 125 units per sub trunk line.

(1)Audio signal line

(2)Video signal line

(3)Power supply line

a.Entrance station (For details, see 2-1 and 2-2)

b.Bus control unit

c.Residential station (For details, see 2-4): Station-to-station wiring (For details, see 1-1)

d.Residential station (For details, see 2-4): Homerun wiring (For details, see 1-1)

Do not mix station-to-station wiring and homerun wiring on a single trunk line.

e.Security Guard Station

f.Expanded Bus control unit

[1]Expanded video Bus control unit GH-VBX

[2]Expanded Bus control unit GH-BCX/A

[3]Distribution terminal (junction): Not included

[4]Power supply PS-2410LC, PS-2410LD, PS-2410DIN

 

Capacity

Entrance Station

Maximum 16 stations

 

(up to 3 stations per trunk)

 

 

Residential stations

Maximum 125 stations

per Sub trunk line

(up to 25 stations per trunk)

Residential Station

Maximum 500 stations

Security Guard Station

Maximum 4 stations

Residential stations

Maximum 4 stations

in the same residence

(up to 2 monitor stations)

Bus control unit

Maximum 1 unit

per Common trunk line

 

Bus control unit

Maximum 1 unit

per Sub trunk line

 

1-3

Wiring Distance

DP = Distribution Point

Diameter of wires

0.65 mm

0.8 mm

1.0 mm

(22 AWG)

(20 AWG)

(18 AWG)

 

GH-BC - DP

-

5 m

-

 

 

(16')

 

DP - GH-DA/A

-

300 m

-

 

 

(980')

 

GH-VBC - GH-VA

150 m

300 m

-

 

(490')

(980')

 

GH-MK - DP

-

300 m

-

 

 

(980')

 

DP - farthest residential station

-

300 m

-

(R1-R2)

 

(980')

 

(Includes system with GH-4Z)

 

 

 

 

 

 

 

GH-VBC - farthest residential station

100 m

150 m

-

(1 monitor unit/residence)

(330')

(500')

 

(Includes system with GH-4Z)

 

 

 

GH-VBC - farthest residential station

50 m

100 m

150 m

(2 monitor units/residence)

(165')

(330')

(500')

(Includes system with GH-4Z)

 

 

 

GH-VBC (SW: STD)

100 m

150 m

-

- GH-VBC (SW: EXP)

(330')

(500')

 

GH-BC - power supply

-

5 m

5 m

 

 

(16')

(16')

 

 

 

 

GH-VBC - power supply

-

5 m

5 m

 

 

(16')

(16')

GH-NS - power supply

-

300 m

300 m

 

 

(980')

(980')

GH-MK - power supply

-

300 m

300 m

 

 

(980')

(980')

Standard system

-

2500 m

-

total wiring distance

 

(8200')

 

 

 

 

 

GH-BCX/A - power supply

-

5 m

5 m

 

 

(16')

(16')

GH-BC - GH-BCX/A

-

300 m

-

 

 

(980')

 

GH-VBC - GH-VBX

-

150 m

-

 

 

(500')

 

GH-DA/A - GH-BCX/A

-

300 m

-

 

 

(980')

 

GH-VA - GH-VBX

150 m

300 m

-

 

(500')

(980')

 

 

 

 

 

GH-BCX/A - farthest residential station

-

300 m

-

(R1-R2)

 

(980')

 

(Includes system with GH-4Z)

 

 

 

GH-VBX - farthest residential station

100 m

150 m

-

(1 monitor unit/residence)

(330')

(500')

 

(Includes system with GH-4Z)

 

 

 

 

 

 

 

GH-VBX - farthest residential station

50 m

100 m

150 m

(2 monitor units/residence)

(165')

(330')

(500')

(Includes system with GH-4Z)

 

 

 

 

 

 

 

Expanded system

-

each

-

total per Common trunk line

 

2500 m

 

(maximum 2 trunk lines)

 

(8200')

 

Expanded system

-

each

-

total per Sub trunk line

 

2500 m

 

(maximum 4 trunk lines)

 

(8200')

 

- 7 -

Image 7
Contents GH Series Precautions PS24 System ConfigurationStandard System Configuration System Configuration PS24 Wiring Distance Expanded System Configuration DiagramUnit Entrance Station ComponentsUnit Bus Control Unit and Others Combination Examples for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA/A Bus Control Unit and Power Supply GH-1AD GH-1KD Optional HandsetSecurity Guard Station Wall-mounting Standard system WiringHomerun wiring with GH-4Z Station-to-station wiring SW1 Standard System Standard System 2 Station-to-Station WiringGH-1MD Standard System 3 Homerun Wiring Expanded system SW1 PS24 Expanded System External Signaling Relay ConnectionResidential station GH-1AD, GH-1KD Names Entrance Station Names Residential StationGH-10K Entrance StationResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Enter Program ModeMenu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK Operations Entrance Station 10-1Calling a Residential Station 11-1 10-210-3 11-3 211-6 11-2 11-511-4 11-7 11-8 Emergency AlarmMonitoring Entrance Stations Replying to a Call from a Residential Station 12-112-2 Replying to a Call from an Entrance StationCalling an Entrance Station 12-3 12-4Calling Another Security Guard Station 12-512-6 Emergency Call12-8 12-712-9 Technical precautions Technical Precautions SpecificationsSpecifications Warranty