Emergency Alarm

1.Press and lock the emergency alarm switch (or when there is a line - off trouble).

2.An alarm will sound from the residential station.

3.When there is a call from the security guard station, the alarm will change to a standard call tone and sound for approximately 45 seconds.

4.Press the talk button to communicate with the security guard station. After talking, the emergency alarm will begin to sound again.

5.Release the lock position of the emergency alarm switch to return to standby position (restore the system to normal status).

NOTES: 1. On the residential station, the emergency alarm will be emitted at a loud volume, regardless of the volume setting.

2.The emergency alarm function can be activated even when the system is in use. (Alarms can be activated at the same time by up to 10 residences.)

3.Residential stations within the same residence will be unable to receive normal calls or doorbell calls while the emergency alarm is sounding. It is only possible to respond call from the security guard station.

4.During the emergency alarm, the entrance station cannot make calls to the residential station that set off the alarm or to the security guard station.

Monitoring Entrance Stations

With a monitor station, you can monitor entrance stations if you press the door release button in standby mode. You can switch between the entrance stations by pressing the door release button. NOTES: 1. Entrance monitoring is possible for only one

residential station at a time.

2.If you press the talk button while monitoring, you can communicate with that entrance station.

3.If a call is received while monitoring, monitoring is terminated.

4.Monitoring lasts for 30 seconds. If you press the door release button within the 30 seconds, the monitor screen will switch to the next entrance station and the 30 second monitoring timer will restart.

5.For information on setting up the monitor, see 4-1 [3].

- 41 -

Image 41
Contents GH Series Precautions PS24 System ConfigurationStandard System Configuration System Configuration PS24 Wiring Distance Expanded System Configuration DiagramUnit Entrance Station ComponentsUnit Bus Control Unit and Others Combination Examples for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA/A Bus Control Unit and Power Supply GH-1AD GH-1KD Optional HandsetSecurity Guard Station Wall-mounting Standard system WiringHomerun wiring with GH-4Z Station-to-station wiring SW1 Standard System Standard System 2 Station-to-Station WiringGH-1MD Standard System 3 Homerun Wiring Expanded system SW1 PS24 Expanded System External Signaling Relay ConnectionGH-10K Names Entrance Station Names Residential StationEntrance Station Residential station GH-1AD, GH-1KDResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Enter Program ModeMenu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK Calling a Residential Station 10-1Operations Entrance Station 10-3 10-211-1 11-4 11-2 11-511-3 211-6 Monitoring Entrance Stations Emergency Alarm11-7 11-8 12-2 12-1Replying to a Call from an Entrance Station Replying to a Call from a Residential StationCalling an Entrance Station 12-3 12-412-6 12-5Emergency Call Calling Another Security Guard Station12-9 12-712-8 Specifications Technical Precautions SpecificationsTechnical precautions Warranty