Aiphone 0207 AIC operation manual Program Mode GH-NS

Page 33

8-6

Program Mode (GH-NS)

1.Menu 1: Select language

Choose language to be displayed on GH-NS.

2.Menu 2: Change ID code

Enter new ID code starting with "", then 4-digit number. (Example: 1234)

3.Menu 3: Set access code

Enter new 4-digit Access Code. (Example: 1234)

(0000) cannot be registered as an access code.

Recommend not to use a simple access code such as (1111).

4.Menu 4: Write in resident information Register room #s and resident names. Enter room #s using 1 to 6-digit characters. Enter resident name (up to 16 characters).

5.Menu 5: Set input timeout timer

Operation Timer: If the operation panel is not operated for a certain period of time, the system returns to standby mode. Programmable from 15 to 99 seconds.

Program Timer: If, in Residential Programming mode, the operation panel is not operated for a certain period of time, it automatically cancels the programming mode. Programmable from 30 to 99 seconds.

Call Timer: Call from Entrance panel expires in a certain period of time. Programmable from 30 to 99 seconds.

6.Menu 6: Change greeting

Enter greeting message (up to 160 characters).

7.Menu 7: Transfer link information

With Expanded System, enter unit ID# for transferring Entrance stations and Security guard stations as below;

Entrance station: Connected to same common line - "programmed ID#" as is. (e.g. transferring to #2: Enter "2"), or Connected to another common line - "programmed ID# plus 8" (e.g. transferring to #1: 1+8=9, Enter "9")

Security guard station: Connected to same common line - "programmed ID#" as is. (e.g. transferring to #2: Enter "2"), or Connected to another common line - "programmed ID# plus 2" (e.g. #1: 1+2=3, Enter "3")

8.Menu 8: Set the greeting scroll speed 0 = slow, 9 = fast

- 33 -

Image 33
Contents GH Series Precautions PS24 System ConfigurationStandard System Configuration System Configuration PS24 Wiring Distance Expanded System Configuration DiagramUnit Entrance Station ComponentsUnit Bus Control Unit and Others Combination Examples for Entrance StationSecurity Guard Station Residential StationMounting the Entrance Station MountingGH-DA/A Bus Control Unit and Power Supply GH-1AD GH-1KD Optional HandsetSecurity Guard Station Wall-mounting Standard system WiringHomerun wiring with GH-4Z Station-to-station wiring SW1 Standard System Standard System 2 Station-to-Station WiringGH-1MD Standard System 3 Homerun Wiring Expanded system SW1 PS24 Expanded System External Signaling Relay ConnectionGH-10K Names Entrance Station Names Residential StationEntrance Station Residential station GH-1AD, GH-1KDResidential station GH-1MD Names Security Guard StationEntering Names and Addresses Adjusting the Camera AngleMaking Adjustments with the Mounting Gauge Setting up the System Programming GH-NS Enter Program ModeMenu Program Mode GH-NS Select Menu & Quit Setting UP Security Guard StationProgramming GH-MK Menu Program Mode GH-MK 10-1 Operations Entrance StationCalling a Residential Station 10-2 11-110-3 11-2 11-5 11-3 211-611-4 Emergency Alarm 11-7 11-8Monitoring Entrance Stations 12-2 12-1Replying to a Call from an Entrance Station Replying to a Call from a Residential StationCalling an Entrance Station 12-3 12-412-6 12-5Emergency Call Calling Another Security Guard Station12-7 12-812-9 Technical Precautions Specifications Technical precautionsSpecifications Warranty