Fn - Select Modulation (Compatibility only)

This command selects the modulation to be used during data connection.

This command is enabled for compatibility only, and using N command and S37 register is the recommended way of selecting the desired modulation.

The F command will change the settings of both the N command and the S37 register.

F0 Enables automoding. Sets N1, sets S37 to 0. This command instructs the modem to connect at the highest speed supported by both modems. (default)

F1 Disables automoding. This command sets N0, sets S37 to 1.

F2 Disables automoding. This command sets N0, sets S37 to 0.

F3 Disables automoding. This command sets N0, sets S37 to 7.

F4 Disables automoding. This command sets N0, sets S37 to 5.

F5 Disables automoding. This command sets N0, sets S37 to 6.

F6 Disables automoding. This command sets N0, sets S37 to 8.

F7 Disables automoding. This command sets N0, sets S37 to 12.

F8 Disables automoding. This command sets N0, sets S37 to 9.

F9 Disables automoding. This command sets N0, sets S37 to 10.

F10 Disables automoding. This command sets N0, sets S37 to 11.

Hn - Disconnect and hook control

H0 If in on-line mode this command will instruct the modem to initiate disconnect procedure, and then go on-hook. If already off-line this command will simply force the modem to go on-hook.

H1 If on-hook, The modem will go off-hook.

In - Modem Identification

I0 Reports product code.

I1 Returns OK.

I2 Returns OK.

I3 Reports The modem version.

Mn - Speaker Control

This command controls the speaker of the modem.

M0 Speaker is always off

M1 Speaker is on during call setup, and off after connect (default)

M2 Speaker is always on

M3 Speaker is off during call setup, but on during answering

Nn - Automoding Control

This command controls automoding.

N0 Automoding is disabled. The data connection will be attempted according to S37 setting.

N1 Automoding is enabled. The highest speed is controlled by S37 register. If S37 is set to 0, The connection will be established at the highest speed supported by both modems.

(default)

38

Image 39
Contents Handheld PC Hardware Users Guide Information to Users ICES-003 Statement Important Safety InstructionsPage Page Page Industry Canada Terminal Equipment Statement Page Page MIC WelcomePicture from the Bottom of the Handheld PC Running your Handheld PC Batteries and powerOperating your Handheld PC with the Main batteries To insert the rechargeable Li-ion battery packTo change the main battery Operating your Handheld PC with the AC adapter Charging rechargeable Li-ion battery packNotification LED Using the stylus Pen Wireless infrared transferTo use the stylus Pen Left Side View of Handheld PC Interface cablePC card slot To insert a PC cardTo remove a PC card Using the CF card. also known as Compact Flash card To insert a CF cardTo remove a CF card To use a modem RAM/ROM Slot To change ROM board VGA Output Of Pocket PowerPoint Viewer Installation & Start-UpGeneral Description Usage ESC Using the Voice Recorder Page To assign application to User1 and User2 To use Quick Launch KeyTo decrease display contrast Adjusting the display contrastTo use and key To increase display contrastResetting your Handheld PC To perform a simple resetTo perform a full reset Precautions Hardware SpecificationsPhysical Description and Features Weight Peripheral and Transfer Interface PowerCF Card Compatibility PC Card CompatibilityData Compression Error CorrectionCompatibility Specification StandardAnswer Re-execute CommandAT= x Write to Selected S-Register AT? Read Selected S-RegisterEn Command Echo Dn DialDial Modifiers Mn Speaker Control Fn Select Modulation Compatibility onlyHn Disconnect and hook control Modem IdentificationSet Tone Dial Default On Return to On-Line Data ModeSet Pulse Dialing as a default Sn Access S-RegisterXn Extended Result Codes Control RING, no CARRIER, ERROR, no DIALTONE, Connect RateSummary of Supported Result Codes Cn DCD Data Carrier Detect Option Zn ResetFn Restore Default Configuration Yn Long Space DisconnectKn Flow Control Mn Mode SelectionQn Mode Selection Gn Select Guard Tone\Nn Selects Operating Mode Display Current ConfigurationWn Store Current Configuration Yn Selects a Default Reset Profile1.AT% Commands Enable/Disable Data Compression RingConnect 1200 Connect 75 Connect 1200 BusyCompression None Compression V.42bisS1 Ring Counter S0 Number of Rings to Auto-AnswerS4 Line Feed Character S8 Pause Time For Dial DelayS2 Escape Character S3 Carriage Return CharacterS37 Desired Line Connection Speed S11 Dtmf Tone DurationS12 Escape Guard Time S36 Lapm Failure ControlS83 EC Negotiation timeout S38 Delay Before Forced Hang UpFax Modulation Table Value Modulation & Speed +FCLASS=n Select Service Class+Fcommand? Report Active Configuration +Fcommand=? Report Operating Capabilities+FTH=n Transmit Data with Hdlc Framing +FRS=n Receive Silence+FTM=n Transmit Data +FRM=n Receive DataPage Page HDECLARATION of Conformity Spring,1998