Grandstream Networks HT-286 ILBC frame size, ILBC payload type, Silence Suppression, Fax Mode

Page 19

 

iLBC frame size

 

This defines the size of the iLBC codec frame. The default setting is 20ms.

 

 

 

 

 

 

 

 

 

 

 

iLBC payload type

 

This defines the iLBC payload type. The default setting is 97. The valid

 

 

 

 

range is between 96 and 127.

 

 

 

 

 

 

 

 

 

 

 

 

Silence Suppression

 

This controls the silence suppression/VAD feature of G723 and G729. If set

 

 

 

 

to “Yes”, when a silence is detected, small quantity of VAD packets (instead

 

 

 

 

of audio packets) will be sent during the period of no talking. If set to “No”,

 

 

 

 

this feature is disabled.

 

 

 

 

 

 

 

 

 

 

 

 

Voice Frames per TX

 

This field contains the number of voice frames to be transmitted in a single

 

 

 

 

packet. When setting this value, the user should be aware of the requested

 

 

 

 

packet time (used in SDP message) as a result of configuring this parameter.

 

 

 

 

This parameter is associated with the first vocoder in the above vocoder

 

 

 

 

Preference List or the actual used payload type negotiated between the 2

 

 

 

 

conversation parties at run time.

 

 

 

 

 

e.g., if the first vocoder is configured as G723 and the “Voice Frames per TX”

 

 

 

 

is set to be 2, then the “ptime” value in the SDP message of an INVITE

 

 

 

 

request will be 60ms because each G723 voice frame contains 30ms of

 

 

 

 

audio. Similarly, if this field is set to be 2 and if the first vocoder chosen is

 

 

 

 

G729 or G711 or G726, then the “ptime” value in the SDP message of an

 

 

 

 

INVITE request will be 20ms.

 

 

 

 

 

If the configured voice frames per TX exceeds the maximum allowed value,

 

 

 

 

the phone will use and save the maximum allowed value for the

 

 

 

 

corresponding first vocoder choice. The maximum value for PCM is

 

 

 

 

10(x10ms) frames; for G726, it is 20 (x10ms) frames; for G723, it is 32

 

 

 

 

(x30ms) frames; for G729/G728, 64 (x10ms) and 64 (x2.5ms) frames

 

 

 

 

respectively.

 

 

 

 

 

 

 

 

 

 

 

 

Fax Mode

 

T.38 (Auto Detect) FoIP by default, or Pass-Through (must use codec

 

 

 

 

PCMU/PCMA)

 

 

 

 

 

 

 

 

 

 

 

 

Layer 3 QoS

 

This field defines the layer 3 QoS parameter which can be the value used for

 

 

 

 

IP Precedence or Diff-Serv. Default value is 48

 

 

 

 

 

 

 

 

 

 

 

 

Layer 2 QoS

 

This setting includes two fields. The 802.1Q/VLAN Tag contains the value

 

 

 

 

used for layer 2 VLAN tag. Default setting is blank. And 802.1p priority value

 

 

 

 

contains the value of the priority value.

 

 

 

 

 

 

 

 

 

 

 

 

Allow incoming SIP

 

If set to “Yes”, the device will ignore any SIP message that does not come

 

 

messages from SIP

 

from the IP address (Source IP in the IP header) that it is registered

 

 

proxy only

 

to. Default is No.

 

 

 

 

 

 

 

 

 

 

 

 

Use DNS SRV

 

This parameter controls whether the IP phone supports the DNS SRV route

 

 

 

 

function.

 

 

 

 

 

 

 

 

 

 

 

 

User ID is phone

 

If the HandyTone-286 has an assigned PSTN telephone number, then this

 

 

number

 

field will be set to “Yes”. Otherwise, set it to “No”. If “Yes” is set, a

 

 

 

 

“user=phone” parameter will be attached to the “From” header in SIP request.

 

 

 

 

 

 

 

 

 

 

 

SIP Registration

 

This parameter controls whether the IP phone needs to send REGISTER

 

 

 

 

messages to the proxy server. The default setting is “Yes”.

 

 

 

 

 

 

 

 

 

 

 

 

Unregister On Reboot

 

Default is No. If set to yes, the device will first send registration request to

 

 

 

 

remove previous bindings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grandstream Networks, Inc.

HT–286 User Manual

Page 19 of 28

 

 

 

Firmware 1.1.0.31

Last Updated: 1/2009

Image 19
Contents Grandstream Networks, Inc Connecting the HT286 HT-286 User Manua l Welcome Button and two colors led indicator InstallationFXS port to be connected to analog phones / fax machines Three Easy Steps to Install the HT-286 Product Overview Physical Design ProvisioningFax over IP SecurityMain Menu Basic OperationsExamples E101E E102E E103E E104EExpected outcomes Star Code Style 3-way Conference Attended TransferBellcore Style 3-way Conference Flash/Hook Call Features38 Fax LED Light Pattern IndicationButton flashes every 6 seconds Button flashes every 1 secondButton flashes every 2 seconds Button flashes every 4 secondsConfiguration Guide Web Port End User PasswordPPPoE password PPPoE Service NameProduct Model Daylight Savings TimeMAC Address WAN IP AddressPassword Admin PasswordAuthenticate ID AuthenticateILBC payload type Fax ModeUnregister On Reboot ILBC frame sizeEarly Dial Timeout Use # asRegistration ExpirationNAT Traversal Enable Call FeatureDisable Call Waiting Disable Call-WaitingPolarity Reversal Special FeaturesCaller ID Scheme Onhook VoltageSyslog Level Caller Request TimerCallee Request Timer Force TimerConfig File Postfix Firmware UpgradeConfig Server Path Config File PrefixSaving the Configuration Changes Instructions to download a free Tftp Server Software UpgradeConfiguration File Download Step Restore Factory Default Setting