| Firmware Upgrade |
| Default HTTP. Firmware upgrading may take up to 10 minutes depends on |
| |
| and Provisioning |
| network environment. Do not interrupt the firmware upgrading process. |
| |
|
|
|
|
|
|
|
|
|
|
| |
| Firmware Server Path |
| IP address or domain name of firmware server. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Config Server Path |
| IP address or domain name of configuration server |
|
|
|
|
|
|
|
|
|
|
| |||
| Firmware File Prefix |
| Default blank. If it is configured, HT286 rev. 3.0 will request the firmware file |
| |
|
|
| with the prefix. Useful for ITSPs. End user should keep it blank. |
| |
|
|
|
|
|
|
|
|
|
|
| |
| Firmware File Postfix |
| Default is blank. End user should keep it blank. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Config File Prefix |
| Default is blank. End user should keep it blank. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Config File Postfix |
| Default is blank. End user should keep it blank. |
|
|
|
|
|
|
|
|
|
|
| |||
| Automatic Upgrade |
| Choose “Yes” to enable automatic upgrade and provisioning and input the |
| |
|
|
| number, in minutes, you want the HT to check for an update. When set to No, |
| |
|
|
| HT286 will only do upgrade once at boot up. “Always check for New |
| |
|
|
| Firmware at Boot up” will check for new firmware every time the device |
| |
|
|
| reboots. “Check New Firmware only when F/W pre/suffix changes” will check |
| |
|
|
| for updates only when the pre/suffix has been changed. |
|
|
|
|
|
|
|
|
|
|
| |||
| Firmware Key |
| 32 digit in Hexadecimal Representation. Useful for ITSP to encrypt firmware. |
| |
|
|
| End user should keep it blank. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Authenticate Conf |
| Default No. End user should use default setting. |
|
|
| File |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Lock keypad update |
| If this parameter is set to “Yes”, except for IVR MENU items 1 to 5, the |
| |
|
|
| configuration update via keypad is disabled. |
|
|
|
|
|
|
|
|
|
|
| |||
| Allow conf SIP |
| If set to Yes, these four fields: SIP User ID, Authenticate ID, Authenticate |
| |
| Account |
| Password and Name will be included in Basic Settings configuration page. |
| |
| in Basic Settings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Override MTU size |
| Override the MTU size. |
|
|
|
|
|
|
|
|
|
|
| |||
| Volume Amplification |
| Handset volume adjustment. RX is for receiving volume, TX is for |
| |
|
|
| transmission volume. Default values are 0dB for both parameters. +6dB |
| |
|
|
| generates the highest volume and |
| |
|
|
|
|
|
|
|
|
| |||
| Powerline Ring Tone |
| This setting allows user to configure the ringing frequencies and cadences. |
| |
|
|
|
|
|
|
|
|
| |||
| Call Progress Tones |
| Using these settings, users can configure various call progress tone |
| |
|
|
| frequencies and cadences according to their country standard. By default |
| |
|
|
| they are set to North American standard. |
|
|
|
|
| Frequencies should be configured with known values to avoid uncomfortable |
| |
|
|
| high pitch sounds. ON is the period of ringing (“On time” in ‘ms’) while OFF is |
| |
|
|
| the period of silence. In order to set a continuous ring, OFF should be zero. |
| |
|
|
| Otherwise it will ring ON ms and a pause of OFF ms and then repeat the |
| |
|
|
| pattern. Up to three cadences are supported. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Disable Line Echo |
| Default is No. If set to Yes, echo canceller is not used. |
|
|
| Canceller (LEC): |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Grandstream Networks, Inc. | Page 24 of 28 | ||||
|
|
| Firmware 1.1.0.31 | Last Updated: 1/2009 |