Uniden BC780XLT manual Search Hold Feature, Data Skip, Frequency Skip

Page 37

Search Hold Feature

1. Press HOLD/at anytime to stop the search.

2. Press HOLD/to move to the next higher frequency.

––– OR –––

Press LIMIT/to move down to the previous frequency.

3. Press SRCH to resume searching.

Data Skip

A scanner will normally stop on any transmission it receives. This means the BC780XLT will occasionally stop on data signals and unmodulated transmissions. You can automatically skip many of these types of transmissions during search. To activate the data skip feature, enter into the menu mode.

1. Press MENU.

2. Press or to select SYSTEM DATA and then press E.

3.Press or to select DATA SKIP and then press E.

4.Set to ON using , or VFO and then press E. DATA appears on the display.

When data skip is active, your scanner may pause momentarily on an unwanted signal but will resume searching in 2 or 3 seconds. Data Skip does not function during AM/WFM band scan, chain search, or WX search, Priority Scan, and Trunking Mode.

Frequency Skip

If a particular frequency continues to interrupt search scanning, it is possible to set your scanner to skip the frequency.

To skip over a frequency, press L/O when stopping at the frequency you want to skip.

Note: • You can program up to 200 skip frequencies. The 201st skip frequency entered causes the first skipped frequency to unlock.

• If all frequencies in the search range are set to skip, it moves to Search hold mode.

To resume searching, do as follows:

1)Cancel the frequency skip set, or

2)Reset the search frequency range.

To cancel all skipped frequencies, press and hold L/O for 2 seconds.

29

Image 37
Contents BC780XLT Introduction Front View and Display Rear View Page Page Contents Inside back cover Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Information on the Internet Where to Obtain More InformationIncluded with Your Scanner Connecting an Antenna SetupMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Applying Power Using Standard AC Power Desktop InstallationConnecting an External Speaker Connecting the Clone Cable Connecting an EarphoneConnecting the Tape Recorder Listening SafelyBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System 2SCREEN Mask Menu Description and Numeric Keypad Equivalents10BANK TAG 6STEPS 7I-CALLMOTOROLA and Edcs 0CONTROL CH only Motorola 800 & 900 Systems 3ATTENUATOR Storing Frequencies into Channels ProgrammingStoring Text Tags Duplicate Frequency AlertAssigning a Bank Tag to a Bank Assigning a Text Tag to a ChannelProgramming Tips Beep AlertDeleting a Stored Frequency Assigning the beep alert to a channelScanning To directly access a specific channelSetting the Delay Mode RF Attenuation FeatureLockout in Scanning Mode Lockout in Manual ModeChannel Lockout Restoring All Locked-out Channels Restoring a Locked-out ChannelPriority Scan Changing the Priority Channel Searching Setting a Search RangeData Skip Search Hold FeatureFrequency Skip Auto Storing Storing Search FrequenciesSquelch SQ Mode Additional Menu Options for Searching Service Search Skip Service SearchWeather Channel Search Testing the Alert SirenNWR-SAME Alert Programming Fips Code Trunked Systems Programming Trunking Frequencies Programming and Receiving Trunked SystemsSelecting Trunking System Type Selecting Trunking Programming Menu ModeTrunked Search Receiving Trunked SystemsID Lockout ID Hold and Direct Entry ID Hold ModeRestoring Locked-out IDs Channel Activity IndicatorsTo unlock a single ID, follow these steps To unlock all locked out IDs in a bank at onceProgramming ID Scan Lists Manually Scan ListsTo enter a Type I ID To enter an Edacs ID Program ID Manually with the Menu ModeTo enter a LTR ID ID Scan Mode Programming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Moving between Scan List MemoriesMotorola Type Call Motorola/EDACSMulti-Track Calls in Scan and Manual ModeScan & Search Icons Edacs Tracking Edacs ReceptionAn EDACSTrunked system AFS Partial Entry Feature Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet MapProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Remote Interface SmartScan ModeTo connect Scanner to PC To perform the SmartScan Download To connect Scanner to External ModemPage Bank Lock Menu for SmartScanTransfer Speed Flow Control Smart Scanner TipsDial Type Page Start Remote Mode Remote PC Control ModeTo program your scanner PC Control ParameterChange Transfer Speed Clone ModeTo connect the scanner to scanner Complete displays Dimmer Additional FeaturesEnter Lock Key Beep OptionReceiving Mode Selection Reverse ModeFrequency and Channel Tuning with the VFO Control Mute On/OffCare and Maintenance Troubleshooting Page Specifications Glossary of terms Glossary of TermsPage Page Appendix Preset Fleet MapsS11 S12 Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code Reverse List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo Page Page Page Page Uniden America Corporation One Year Limited WarrantyCovered under one or more of the following U.S. patents

BC780XLT specifications

The Uniden BC780XLT is a versatile and popular scanner that has made a name for itself among scanning enthusiasts and professionals alike. Released in the early 2000s, this model is known for its extensive feature set, allowing users to monitor a wide range of frequencies and communications.

One of the primary features of the BC780XLT is its capability to scan multiple frequency bands, including VHF, UHF, and 700/800 MHz frequencies. This makes it an ideal choice for monitoring public safety communications, utility services, and various other two-way radio frequencies. The scanner operates in an impressive frequency range of 25 MHz to 1.3 GHz, allowing users to enjoy a broad spectrum of signals.

The BC780XLT features TrunkTracker technology, which enables it to follow trunked radio systems. This is crucial for monitoring communications from agencies that operate on these complex frequency systems, like police and fire departments. The scanner can decode both Motorola and EDACS trunked systems, providing extensive coverage of public safety communications.

User-friendly controls and advanced features make the BC780XLT accessible for both beginners and experienced users. The numeric keypad allows for quick entry of frequencies, while the large LCD display provides easy visibility of channel information, including frequency and mode. The 10-channel pre-programmed memory allows users to store their favorite frequencies and easily scan between them.

In addition to its scanning capabilities, the BC780XLT also supports close call technology. This feature allows the scanner to automatically detect nearby signals, instantly alerting users to any active frequencies in their vicinity. This is particularly useful for users in urban areas, where multiple frequencies may be in use simultaneously.

The BC780XLT also has a robust battery-saving feature, making it an excellent option for those who need to scan on the go. This functionality, coupled with its ability to operate on AC or DC power, adds to its versatility, ensuring uninterrupted scanning during extended use or in field operations.

In conclusion, the Uniden BC780XLT Scanner stands out for its comprehensive feature set, including TrunkTracker technology, extensive frequency coverage, and user-friendly design. Whether for hobbyists, emergency responders, or professionals needing reliable communication, the BC780XLT continues to be a valuable tool in the world of scanning. Its enduring popularity speaks to its performance and adaptability in a rapidly evolving technological landscape.