To enter an EDACS® ID:

a. Enter ID you want to store.

Use the for the “dash”. b. Press E.

Hint: Remember that Uniden's AFS format allows you to enter full or partial EDACS IDs for powerful flexibility in all modes. Be sure to read the section "EDACS Reception" on page 49 to learn how this works.

Note: The BC780XLT defaults to “AFS” talkgroup displays for EDACS ® only.

––– OR –––

To enter a LTR ID:

a. Enter Area code and then press .

b.Enter Home Repeater number and then press .

c.Enter ID you want to store and then press E.

Note: To clear a mistake while entering an ID, press

and E successively, and

start over.

 

4. Press MAN or HOLD/to select the next Scan List location.

Program ID Manually with the Menu Mode

Note: It is also possible to do ID programming in the menu mode by selecting TRUNK DATA

-BANK NO. - PROGRAM ID. Do the following:

1.Press MENU.

2.Press or to select TRUNK DATA and then press E.

3.Press or to select the bank no. and then press E.

4.Press or to select the PROGRAM ID and then press E.

Remember! You can also use the VFO control for scrolling. Also instead of pressing E, you can press the VFO/SELECT control or press the SELECT/MUTE key.

5. Select the ID location using the VFO control, keypad, or and then press E. (first number represents the bank number and second number represents the memory location.)(Direct entry method example: enter

5-1 by pressing 5, ,1.)

6.Press or to select ID and then press E.

7.Enter the ID number using the keypad and then press E.

Note: After you have programmed the ID in a selected bank while still in the menu mode, you can set your alpha tag (see page 21), flag the individual ID or talkgroup for recording (see page 32 and 11), or turn on the beep alert for an individual talkgroup (see page 22).

43

Image 51
Contents BC780XLT Introduction Front View and Display Rear View Page Page Contents Inside back cover Important Notice Terminology What is Scanning?What is Searching? What is Trunk Tracking?Page Feature Highlights Information on the Internet Where to Obtain More InformationIncluded with Your Scanner Optional Antenna SetupConnecting an Antenna Mounting an AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Listening Safely Connecting an EarphoneConnecting the Clone Cable Connecting the Tape RecorderSetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System 2SCREEN Mask Menu Description and Numeric Keypad Equivalents10BANK TAG 6STEPS 7I-CALLMOTOROLA and Edcs 0CONTROL CH only Motorola 800 & 900 Systems 3ATTENUATOR Storing Frequencies into Channels ProgrammingAssigning a Text Tag to a Channel Duplicate Frequency AlertStoring Text Tags Assigning a Bank Tag to a BankAssigning the beep alert to a channel Beep AlertProgramming Tips Deleting a Stored FrequencyScanning To directly access a specific channelSetting the Delay Mode RF Attenuation FeatureLockout in Manual Mode Lockout in Scanning ModeChannel Lockout Restoring a Locked-out Channel Restoring All Locked-out ChannelsPriority Scan Changing the Priority Channel Searching Setting a Search RangeSearch Hold Feature Data SkipFrequency Skip Auto Storing Storing Search FrequenciesSquelch SQ Mode Additional Menu Options for Searching Service Search Skip Service SearchTesting the Alert Siren Weather Channel SearchNWR-SAME Alert Programming Fips Code Trunked Systems Programming Trunking Frequencies Programming and Receiving Trunked SystemsSelecting Trunking System Type Selecting Trunking Programming Menu ModeTrunked Search Receiving Trunked SystemsID Lockout ID Hold and Direct Entry ID Hold ModeTo unlock all locked out IDs in a bank at once Channel Activity IndicatorsRestoring Locked-out IDs To unlock a single ID, follow these stepsScan Lists Programming ID Scan Lists ManuallyTo enter a Type I ID Program ID Manually with the Menu Mode To enter an Edacs IDTo enter a LTR ID ID Scan Mode Moving between Scan List Memories Setting Priority in Trunking ModeProgramming Scan Lists During Search Deleting a Stored IDMotorola Type Call Motorola/EDACSMulti-Track Calls in Scan and Manual ModeScan & Search Icons Edacs Tracking Edacs ReceptionAn EDACSTrunked system AFS Partial Entry Feature Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionSelecting Preset Fleet Map Fleet Map ProgrammingProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code SmartScan Mode Remote InterfaceTo connect Scanner to PC To perform the SmartScan Download To connect Scanner to External ModemPage Menu for SmartScan Bank LockTransfer Speed Smart Scanner Tips Flow ControlDial Type Page PC Control Parameter Remote PC Control ModeStart Remote Mode To program your scannerClone Mode Change Transfer SpeedTo connect the scanner to scanner Complete displays Key Beep Option Additional FeaturesDimmer Enter LockMute On/Off Reverse ModeReceiving Mode Selection Frequency and Channel Tuning with the VFO ControlCare and Maintenance Troubleshooting Page Specifications Glossary of terms Glossary of TermsPage Page Appendix Preset Fleet MapsS11 S12 Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code Reverse List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo Page Page Page Page Uniden America Corporation One Year Limited WarrantyCovered under one or more of the following U.S. patents

BC780XLT specifications

The Uniden BC780XLT is a versatile and popular scanner that has made a name for itself among scanning enthusiasts and professionals alike. Released in the early 2000s, this model is known for its extensive feature set, allowing users to monitor a wide range of frequencies and communications.

One of the primary features of the BC780XLT is its capability to scan multiple frequency bands, including VHF, UHF, and 700/800 MHz frequencies. This makes it an ideal choice for monitoring public safety communications, utility services, and various other two-way radio frequencies. The scanner operates in an impressive frequency range of 25 MHz to 1.3 GHz, allowing users to enjoy a broad spectrum of signals.

The BC780XLT features TrunkTracker technology, which enables it to follow trunked radio systems. This is crucial for monitoring communications from agencies that operate on these complex frequency systems, like police and fire departments. The scanner can decode both Motorola and EDACS trunked systems, providing extensive coverage of public safety communications.

User-friendly controls and advanced features make the BC780XLT accessible for both beginners and experienced users. The numeric keypad allows for quick entry of frequencies, while the large LCD display provides easy visibility of channel information, including frequency and mode. The 10-channel pre-programmed memory allows users to store their favorite frequencies and easily scan between them.

In addition to its scanning capabilities, the BC780XLT also supports close call technology. This feature allows the scanner to automatically detect nearby signals, instantly alerting users to any active frequencies in their vicinity. This is particularly useful for users in urban areas, where multiple frequencies may be in use simultaneously.

The BC780XLT also has a robust battery-saving feature, making it an excellent option for those who need to scan on the go. This functionality, coupled with its ability to operate on AC or DC power, adds to its versatility, ensuring uninterrupted scanning during extended use or in field operations.

In conclusion, the Uniden BC780XLT Scanner stands out for its comprehensive feature set, including TrunkTracker technology, extensive frequency coverage, and user-friendly design. Whether for hobbyists, emergency responders, or professionals needing reliable communication, the BC780XLT continues to be a valuable tool in the world of scanning. Its enduring popularity speaks to its performance and adaptability in a rapidly evolving technological landscape.