Uniden BC780XLT manual Reverse List

Page 90

Event Code

Standard

Event Level (Siren Type)

 

LCD Display

 

 

Warning

Watch

Statement

Test

 

Hurricane/ Tropical Storm Warning

EAN

0

 

 

 

EMG NOTIFY

 

 

 

 

 

 

 

Service Weather Statement

SVS

 

 

0

 

SERVICE WX

Special Weather Statement

SPS

 

 

0

 

SPECIAL WX

Flash Flood Statement

FFS

 

 

0

 

FLASH FLOOD

 

 

 

 

 

 

 

Flood Statement

FLS

 

 

0

 

FLOOD

Hurricane Statement

HLS

 

 

0

 

HURRICANE

National Periodic Test

NPT

 

 

 

0

NATION PERIOD

 

 

 

 

 

 

 

Required Monthly Test

RMT

 

 

 

0

MONTHLY

Required Weekly Test

RWT

 

 

 

0

WEEKLY

System Demonstration/ Practice

DMO

 

 

(No Siren)

LCD

SYSTEM DEMO

 

 

 

 

 

 

 

National Hazard Warning

NHW

0

 

 

 

NATION HAZARD

Unknown Emergency Tune TV

**E

0

 

 

 

UNKNOWN TV

Unknown Warning Tune TV

**W

0

 

 

 

UNKNOWN TV

 

 

 

 

 

 

 

Unknown Watch Tune TV

**A

 

0

 

 

UNKNOWN TV

Unknown Statement Tune TV

**S

 

 

0

 

UNKNOWN TV

REVERSE LIST

Range

Offset

Range

Offset

29.520

- 29.580

+0.1 MHz

445.000 - 449.9875

-5 MHz

29.620

- 29.680

-0.1 MHz

450.000 - 454.9875

+5 MHz

52.010

- 52.990

+1 MHz

455.000 - 459.9875

-5 MHz

53.010

- 53.990

-1 MHz

460.000 - 464.9875

+5 MHz

143.750

+4.375 MHz

465.000 - 469.9875

-5 MHz

143.900

+4.25 MHz

470.000 - 472.9875

+3 MHz

144.510

- 144.890

+0.6 MHz

473.000 - 475.9875

-3 MHz

145.110

- 145.490

-0.6 MHz

476.000 - 478.9875

+3 MHz

146.010

- 146.385

+0.6 MHz

479.000 - 481.9875

-3 MHz

146.415

- 146.505

+1 MHz

482.000 - 484.9875

+3 MHz

146.595

+1 MHz

485.000 - 487.9875

-3 MHz

146.610

- 146.985

-0.6 MHz

488.000 - 490.9875

+3 MHz

147.000

- 147.390

+0.6 MHz

491.000 - 493.9875

-3 MHz

147.415

- 147.505

-1 MHz

494.000 - 496.9875

+3 MHz

147.595

-1 MHz

497.000 - 499.9875

-3 MHz

147.600

- 147.990

-0.6 MHz

500.000 - 502.9875

+3 MHz

148.125

-4.375 MHz

503.000 - 505.9875

-3 MHz

148.150

-4.25 MHz

506.000 - 508.9875

+3 MHz

222.120

- 223.380

+1.6 MHz

509.000 - 511.9875

-3 MHz

223.720

- 224.980

-1.6 MHz

806.000 - 823.9875

+45 MHz

420.000 - 424.9875

+5 MHz

851.000 - 868.9875

-45 MHz

425.000 - 429.9875

-5 MHz

896.000 - 901.000

+39 MHz

440.000 - 444.9875

+5 MHz

935.000 - 940.000

-39 MHz

82

Image 90
Contents BC780XLT Introduction Front View and Display Rear View Page Page Contents Inside back cover Important Notice What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Where to Obtain More Information Information on the InternetIncluded with Your Scanner Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Connecting the Tape Recorder Connecting an EarphoneConnecting the Clone Cable Listening SafelySetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SCREEN Mask10BANK TAG 6STEPS 7I-CALLMOTOROLA and Edcs 0CONTROL CH only Motorola 800 & 900 Systems 3ATTENUATOR Programming Storing Frequencies into ChannelsAssigning a Bank Tag to a Bank Duplicate Frequency AlertStoring Text Tags Assigning a Text Tag to a ChannelDeleting a Stored Frequency Beep AlertProgramming Tips Assigning the beep alert to a channelTo directly access a specific channel ScanningRF Attenuation Feature Setting the Delay ModeLockout in Manual Mode Lockout in Scanning ModeChannel Lockout Restoring a Locked-out Channel Restoring All Locked-out ChannelsPriority Scan Changing the Priority Channel Setting a Search Range SearchingSearch Hold Feature Data SkipFrequency Skip Storing Search Frequencies Auto StoringSquelch SQ Mode Additional Menu Options for Searching Service Search Service Search SkipTesting the Alert Siren Weather Channel SearchNWR-SAME Alert Programming Fips Code Trunked Systems Programming and Receiving Trunked Systems Programming Trunking FrequenciesSelecting Trunking Programming Menu Mode Selecting Trunking System TypeReceiving Trunked Systems Trunked SearchID Hold and Direct Entry ID Hold Mode ID LockoutTo unlock a single ID, follow these steps Channel Activity IndicatorsRestoring Locked-out IDs To unlock all locked out IDs in a bank at onceScan Lists Programming ID Scan Lists ManuallyTo enter a Type I ID Program ID Manually with the Menu Mode To enter an Edacs IDTo enter a LTR ID ID Scan Mode Deleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Moving between Scan List MemoriesCall Motorola/EDACS Motorola TypeCalls in Scan and Manual Mode Multi-TrackScan & Search Icons Edacs Reception Edacs TrackingAn EDACSTrunked system Special Edacs Features AFS Partial Entry FeatureLTR Reception LTR TrackingMotorola Reception Motorola TrackingSelecting Preset Fleet Map Fleet Map ProgrammingProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code SmartScan Mode Remote InterfaceTo connect Scanner to PC To connect Scanner to External Modem To perform the SmartScan DownloadPage Menu for SmartScan Bank LockTransfer Speed Smart Scanner Tips Flow ControlDial Type Page To program your scanner Remote PC Control ModeStart Remote Mode PC Control ParameterClone Mode Change Transfer SpeedTo connect the scanner to scanner Complete displays Enter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Mute On/OffCare and Maintenance Troubleshooting Page Specifications Glossary of Terms Glossary of termsPage Page Preset Fleet Maps AppendixS11 S12 User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsNWR-SAME Event Code Reverse List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo Page Page Page Page One Year Limited Warranty Uniden America CorporationCovered under one or more of the following U.S. patents

BC780XLT specifications

The Uniden BC780XLT is a versatile and popular scanner that has made a name for itself among scanning enthusiasts and professionals alike. Released in the early 2000s, this model is known for its extensive feature set, allowing users to monitor a wide range of frequencies and communications.

One of the primary features of the BC780XLT is its capability to scan multiple frequency bands, including VHF, UHF, and 700/800 MHz frequencies. This makes it an ideal choice for monitoring public safety communications, utility services, and various other two-way radio frequencies. The scanner operates in an impressive frequency range of 25 MHz to 1.3 GHz, allowing users to enjoy a broad spectrum of signals.

The BC780XLT features TrunkTracker technology, which enables it to follow trunked radio systems. This is crucial for monitoring communications from agencies that operate on these complex frequency systems, like police and fire departments. The scanner can decode both Motorola and EDACS trunked systems, providing extensive coverage of public safety communications.

User-friendly controls and advanced features make the BC780XLT accessible for both beginners and experienced users. The numeric keypad allows for quick entry of frequencies, while the large LCD display provides easy visibility of channel information, including frequency and mode. The 10-channel pre-programmed memory allows users to store their favorite frequencies and easily scan between them.

In addition to its scanning capabilities, the BC780XLT also supports close call technology. This feature allows the scanner to automatically detect nearby signals, instantly alerting users to any active frequencies in their vicinity. This is particularly useful for users in urban areas, where multiple frequencies may be in use simultaneously.

The BC780XLT also has a robust battery-saving feature, making it an excellent option for those who need to scan on the go. This functionality, coupled with its ability to operate on AC or DC power, adds to its versatility, ensuring uninterrupted scanning during extended use or in field operations.

In conclusion, the Uniden BC780XLT Scanner stands out for its comprehensive feature set, including TrunkTracker technology, extensive frequency coverage, and user-friendly design. Whether for hobbyists, emergency responders, or professionals needing reliable communication, the BC780XLT continues to be a valuable tool in the world of scanning. Its enduring popularity speaks to its performance and adaptability in a rapidly evolving technological landscape.