Uniden BC780XLT manual Clone Mode, Change Transfer Speed, To connect the scanner to scanner

Page 74

Change Transfer Speed

To change transfer speed, enter into the menu mode.

1.Press MENU.

2.Press or to select SYSTEM DATA and then

press E.

3.Press or to select PC CONTROL and then press E.

4.To change the transfer speed, press or . Then press E.

Clone Mode

You will need to purchase an RS232C cable and a null modem adapter. RS232C cables are available as male to male or male to female. Even if the cable you buy already has the Male to Male connectors, you will still have to have the null modem adapter. Below you will see the pin connections that are internal to a standard device. (These items are available at your local electronics stores.)

To connect the scanner to scanner:

Plug the male end of the RS232C straight interface cables into the remote port on the rear of one of the two scanners. Then connect the DB-9 to DB-9 null modem adapter to the cable. Then plug the the other side of the null modem adapter to the other scanner. (DB9 Gender changers are also available at your local electronics store.)

Null Modem Adapter

Pin connections

Female

Male

DB9

DB9

1

4

2

3

3

2

4

6 & 1

5

5

64

78

87

9Not used

You can clone all of the programming of one BC780XLT into another, including frequencies, talkgroup IDs, alpha tags, delay settings, etc. After connecting the two scanners, turn the radios on. Prepare each scanner for clone mode as follows.

1.Press MENU.

2.Select SYSTEM DATA - CLONE using , or VFO and pressing E, SELECT or VFO.

3.Determine the scanner that has the frequency data that you want to transfer. This one must be set up as the “Master Unit”, and the other must be set as the “Slave Unit”.

4.On the scanner that is the “Master Unit”, select

MASTER, then press E.

66

Image 74
Contents BC780XLT Introduction Front View and Display Rear View Page Page Contents Inside back cover Important Notice What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Where to Obtain More Information Information on the InternetIncluded with Your Scanner Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Connecting an External Speaker Desktop InstallationApplying Power Using Standard AC Power Connecting the Tape Recorder Connecting an EarphoneConnecting the Clone Cable Listening SafelyTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SCREEN Mask10BANK TAG 6STEPS 7I-CALLMOTOROLA and Edcs 0CONTROL CH only Motorola 800 & 900 Systems 3ATTENUATOR Programming Storing Frequencies into ChannelsAssigning a Bank Tag to a Bank Duplicate Frequency AlertStoring Text Tags Assigning a Text Tag to a ChannelDeleting a Stored Frequency Beep AlertProgramming Tips Assigning the beep alert to a channelTo directly access a specific channel ScanningRF Attenuation Feature Setting the Delay ModeChannel Lockout Lockout in Manual ModeLockout in Scanning Mode Priority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels Changing the Priority Channel Setting a Search Range SearchingFrequency Skip Search Hold FeatureData Skip Storing Search Frequencies Auto StoringSquelch SQ Mode Additional Menu Options for Searching Service Search Service Search SkipNWR-SAME Alert Testing the Alert SirenWeather Channel Search Programming Fips Code Trunked Systems Programming and Receiving Trunked Systems Programming Trunking FrequenciesSelecting Trunking Programming Menu Mode Selecting Trunking System TypeReceiving Trunked Systems Trunked SearchID Hold and Direct Entry ID Hold Mode ID LockoutTo unlock a single ID, follow these steps Channel Activity IndicatorsRestoring Locked-out IDs To unlock all locked out IDs in a bank at onceTo enter a Type I ID Scan ListsProgramming ID Scan Lists Manually To enter a LTR ID Program ID Manually with the Menu ModeTo enter an Edacs ID ID Scan Mode Deleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Moving between Scan List MemoriesCall Motorola/EDACS Motorola TypeCalls in Scan and Manual Mode Multi-TrackScan & Search Icons Edacs Reception Edacs TrackingAn EDACSTrunked system Special Edacs Features AFS Partial Entry FeatureLTR Reception LTR TrackingMotorola Reception Motorola TrackingProgramming a Fleet Map Selecting Preset Fleet MapFleet Map Programming Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code To connect Scanner to PC SmartScan ModeRemote Interface To connect Scanner to External Modem To perform the SmartScan DownloadPage Transfer Speed Menu for SmartScanBank Lock Dial Type Smart Scanner Tips Flow Control Page To program your scanner Remote PC Control ModeStart Remote Mode PC Control ParameterTo connect the scanner to scanner Clone ModeChange Transfer Speed Complete displays Enter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Mute On/OffCare and Maintenance Troubleshooting Page Specifications Glossary of Terms Glossary of termsPage Page Preset Fleet Maps AppendixS11 S12 User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsNWR-SAME Event Code Reverse List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo Page Page Page Page One Year Limited Warranty Uniden America CorporationCovered under one or more of the following U.S. patents