Setup menus
INTERFACE
| Item |
| Setting |
| |
|
|
|
| Description of settings | |
No. | Superimposed | No. | Superimposed | ||
| |||||
display | display |
| |||
|
|
| |||
|
|
|
|
| |
|
|
|
|
| |
202 | ID SEL |
|
| For setting the ID information to be returned to the controller. | |
|
| 0000 | OTHER | 0: The ID information of the VTR other than DVCPRO is set. | |
|
| 0001 | DVCPRO | 1: The DVCPRO ID information is set. | |
|
| 0002 | ORIG | 2: Set this only when the unit is connected to a Panasonic controller (such as the | |
|
|
|
| ||
|
|
|
| <Note> | |
|
|
|
| Select 1 (DVCPRO) or 2 (ORIG) if “23/24,” “25(HD)” or “25(SD)” is selected as the | |
|
|
|
| menu item No.25 [SYSTEM FREQ] setting. | |
|
|
|
|
|
TAPE PROTECT
| Item |
| Setting |
| |
|
|
|
| Description of settings | |
No. | Superimposed | No. | Superimposed | ||
| |||||
display | display |
| |||
|
|
| |||
|
|
|
|
| |
|
|
|
|
| |
400 | STILL TIMER | 0000 | 0.5S | For setting the time to be taken before the unit is set in the tape protection mode | |
|
| 0001 | 5S | when it is left standing in the STOP or STILL status. | |
|
| 0002 | 10S | (Units: S = seconds, min = minutes) | |
|
| 0003 | 20S | <Note> | |
|
| 0004 | 30S | When a DV or DVCAM tape is used, any setting above 2 (10S) will result in a | |
|
| 0005 | 40S | setting time of 10 seconds. | |
|
| 0006 | 50S |
| |
|
| 0007 | 1min |
| |
|
| 0008 | 2min |
| |
|
|
|
|
| |
401 | SRC PROTECT |
|
| For setting the operation to be performed in the tape protection mode when the unit | |
|
|
|
| is left standing in the STILL status. | |
|
| 0000 | STEP | 0: STEP FWD | |
|
| 0001 | HALF | 1: Standby OFF (half loading) | |
|
|
|
| <Note> | |
|
|
|
| If STEP FWD is selected, the unit is automatically transferred to the standby OFF | |
|
|
|
| (half loading) mode when the unit is left standing in the STILL mode for a total of 30 | |
|
|
|
| minutes (or 1 minute for DV or DVCAM tape). | |
|
|
|
|
| |
402 | DRUM STDBY |
|
| For setting the cylinder operation in the standby OFF (half loading) mode. | |
|
| 0000 | OFF | 0: The cylinder stops rotating. | |
|
| 0001 | ON | 1: The cylinder continues to rotate. | |
|
|
|
|
| |
403 | STOP PROTECT |
|
| For setting the operation to be performed in the tape protection mode when the unit | |
|
|
|
| is left standing in the STOP status. | |
|
| 0000 | STEP | 0: STEP FWD | |
|
| 0001 | HALF | 1: Standby OFF (half loading) | |
|
|
|
| <Note> | |
|
|
|
| When STEP FWD is selected, the unit is automatically transferred to the standby | |
|
|
|
| OFF (half loading) mode when the unit is left standing in the STOP mode for a total | |
|
|
|
| of 30 minutes (or 1 minute for DV or DVCAM tape). | |
|
|
|
|
|
“” indicates the factory setting.