INTERFACE

 

Item

 

Setting

 

 

 

 

 

Description of settings

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

202

ID SEL

 

 

For setting the ID information to be returned to the controller.

 

 

0000

OTHER

0: The ID information of the VTR other than DVCPRO is set.

 

 

0001

DVCPRO

1: The DVCPRO ID information is set.

 

 

0002

ORIG

2: Set this only when the unit is connected to a Panasonic controller (such as the

 

 

 

 

AJ-A900, optional accessory).

 

 

 

 

<Note>

 

 

 

 

Select 1 (DVCPRO) or 2 (ORIG) if “23/24,” “25(HD)” or “25(SD)” is selected as the

 

 

 

 

menu item No.25 [SYSTEM FREQ] setting.

 

 

 

 

 

TAPE PROTECT

 

Item

 

Setting

 

 

 

 

 

Description of settings

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

STILL TIMER

0000

0.5S

For setting the time to be taken before the unit is set in the tape protection mode

 

 

0001

5S

when it is left standing in the STOP or STILL status.

 

 

0002

10S

(Units: S = seconds, min = minutes)

 

 

0003

20S

<Note>

 

 

0004

30S

When a DV or DVCAM tape is used, any setting above 2 (10S) will result in a

 

 

0005

40S

setting time of 10 seconds.

 

 

0006

50S

 

 

 

0007

1min

 

 

 

0008

2min

 

 

 

 

 

 

401

SRC PROTECT

 

 

For setting the operation to be performed in the tape protection mode when the unit

 

 

 

 

is left standing in the STILL status.

 

 

0000

STEP

0: STEP FWD

 

 

0001

HALF

1: Standby OFF (half loading)

 

 

 

 

<Note>

 

 

 

 

If STEP FWD is selected, the unit is automatically transferred to the standby OFF

 

 

 

 

(half loading) mode when the unit is left standing in the STILL mode for a total of 30

 

 

 

 

minutes (or 1 minute for DV or DVCAM tape).

 

 

 

 

 

402

DRUM STDBY

 

 

For setting the cylinder operation in the standby OFF (half loading) mode.

 

 

0000

OFF

0: The cylinder stops rotating.

 

 

0001

ON

1: The cylinder continues to rotate.

 

 

 

 

 

403

STOP PROTECT

 

 

For setting the operation to be performed in the tape protection mode when the unit

 

 

 

 

is left standing in the STOP status.

 

 

0000

STEP

0: STEP FWD

 

 

0001

HALF

1: Standby OFF (half loading)

 

 

 

 

<Note>

 

 

 

 

When STEP FWD is selected, the unit is automatically transferred to the standby

 

 

 

 

OFF (half loading) mode when the unit is left standing in the STOP mode for a total

 

 

 

 

of 30 minutes (or 1 minute for DV or DVCAM tape).

 

 

 

 

 

” indicates the factory setting.

40

Image 40
Contents Operating Instructions Model No. AJ- PFor your safety Operating precautionDo not Remove Cover or Back Contents Features IntroductionMulti-functional interfaces Parts and their functions Front panelLOCAL/MENU/REMOTE switch Repeat lampSystem format lamp SCH lamp2Audio monitor selector switch ? Analog lamp2@ Meter button and lamp CH34 Audio output lamps CH12, CH34Analog audio signal recording level controls2 Volume control720p lamp Headphone jackREC button2 No optional board installed When the AJ-YA120AG or AJ-YAD120AG is installedTAPE/EE switch Reset buttonRear panel AC in inletDC in socket DC OUT socketTC in connector2 TC OUT connectorHD/SD REF Video in connectors and 75Ω termination switch2 Audio in connectors CH1, CH2, CH3, CH42Precautions for using consumer DV and Dvcam cassettes TapesInserting the tape Usable tapesStop mode Turning on the unit’s powerOperation Recording Pause/recording follow-on recordingPlayback Cue/reviewStill image playback Insert a cassette tape into the unit Press the Play buttonLinear 0.3k playback When AJ-A95 is connectedVariable speed playback Setting the Begin and END points Setting the repeat playback modeSet the VTR to the menu mode Repeat playbackSetting the time code Time code & user’s bitTime code User’s bitSetting the user’s bit Select menu item No.531 UB PresetPlaying back the time code and user’s bit T2R00 07 04Superimposed screen displays Characters displayedRemaining tape display Display positionOperation mode Time modeSTA mode M modeSetup initial settings Setting method using the on- screen menusReturning to the factory settings Set the LOCAL/MENU/REMOTE switch to the Menu positionSetting the user defaults Loading the user defaults Menu protectionDisplaying the Diag menu Releasing the menu protection modeWith the hour meter displayed, press the Search button Setup menus Menus which are displayedTYPE-B Near Audio in SEL Setting Description of settings Superimposed Display Indicates the factory settingSystem System Freq Setting Description of settingsHD SYS H ADV Basic Format Display SYS Format PB FormatManual Auto022 020 023 Playback format Formats for playbackManual Dvcam HD-LP Operation FRZ Mode SEL SP Mode INHMemory Mode Auto REWRept Mode Battery SELCTL BGN TC BGNInterface Tape ProtectTime Code Phase Corr DF ModeTC Preset UB PresetVideo VO Setup HD VO Setup SDBLK Clip CC F1 BlankESR Mode SD CCR Mode SDEDH SD SDI IndexAudio REC CUE CH1CH2 CH3Menu DIF Config DIF SpeedDIF in CH DIF OUT CHError No Error message and description Error messages23/24 Hz mode and 25 Hz mode Unload Error Condensation Operation performed by AJ-HD1200AVideo head cleaning MaintenanceProcedure to ejecting the tape manually in an emergency Emergency ejectSpecifications $ Video input connectors21$ Video output connectors GeneralOther Connectors OptionsExecutive Office Southeast RegionCentral Region Government Marketing Department