GE EPM 3000P instruction manual Back View, Dual-Phase

Page 13

Chapter 2 Electrical Installation

LINE

 

 

BACK VIEW

 

 

N

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

7

8

9

10

11

12

13

 

 

 

6

 

 

 

 

 

 

 

 

 

5

 

PORT

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

+

2

L2

 

 

 

 

 

LOAD

POWER

1 L1

 

 

 

 

 

-

 

 

 

 

 

 

 

DUAL-PHASE

 

 

 

 

 

 

 

 

WITH CTs AND Direct Voltage

 

 

 

VII. Dual-Phase System

2.6RELAYS AND PROTECTION

NOTE: THIS SECTION IS APPLICABLE ONLY IF THE -NL RELAY OPTION WAS ORDERED.

The EPM3000P allows the user to access a variety of relay options through the programming mode. The relay option package consists of two relays, which can be dedicated to alarm or communication (or both).

TIME DELAY: Sets off the alarm, alerting the user that an out-of-limits condition occurred during the defined time limit. The time delay can be programmed for any desirable duration.

If the relays are dedicated to communication, there are two different modes:

ƒ

Lock ON

Relay will not be affected by any alarm condition.

ƒ

Lock OFF

Relay will not be affected by any alarm condition.

If the relays are used for communication and alarm, there are four different modes:

ƒ

Lock ON

Relay stays on regardless of any alarm condition.

ƒ

Lock OFF

Relay stays off regardless of any alarm condition.

ƒ

Free ON

Relay turns on unless other conditions force it off.

ƒ

Free OFF

Relay turns off unless other conditions force it on.

8

GE Industrial Systems

Image 13
Contents EPM 3000P All Rights Reserved Customer Service and Support Installation & O P E R a T I O N O G R a M M I N G Mechanical Installation Installation & OperationPort Mechanical InstallationCT Size VA Maximum Distance CT to EPM3000P Electrical InstallationElectrical Installation Listing of Connection DiagramsWith 2 CTs and 2 PTs With Direct Voltage and CTsWith 3 CTs and 2 PTs III. Open Delta PT ConnectionThree Phase System Wye System with PTs Back View DUAL-PHASECOM RS-232C Communication InstallationRS-485 Communication Installation RS-485 Hookup Diagram 2 wire Half DuplexRS-485 Hookup Diagram 2 wire Half Duplex Detail View Volts Amps EPM3000P Overview‰ Protected Reset ‰ Unprotected ResetEPM3000P Overview Voltage Phase Imbalance Limit Voltage Phase ReversalI000 Access OperationÖTo Print the Programming DATA, follow these steps 222300.0 GROUPS, Functions, and Switch Packs General Procedure OverviewPassword General Procedure OverviewUsed for Standard Numeric Data Entry555 Entering the Programming ModeFunction Number Programming Group 0 Global Meter Setup020 Global Meter SetupI20 Pack Switch Feature Segment Position 03.0 Computer Controlled Dedicated AlarmS E T I25 Input Voltage PT Ratio Full Scale Programming GroupInput Current CT Type Full Scale Programming Group I50Volts 4/1 PT To change the CALIBRATION, follow these steps Programming Group 2 Meter Calibration250 10.1 Programming Group 4 SET Limits & RelaysLM1 LED LM2 LED ABOVE/BELOW Relay Value Set Limits & RelaysLM1 LED LM2 LED ABOVE/ below Relay Level ÖTo program Limits or RELAYS, follow these steps Set Limits and RelaysSee to Exit Percent Phase Imbalance Phase ReversalÖTo change the Phase Reversal settings, follow these steps Phase Reversal & Phase Imbalance Set Limits/RelaysI0.0 If YOU are Located AT Exiting the Programming Mode

EPM 3000P specifications

The GE EPM 3000P is a cutting-edge power monitoring and management device designed to enhance the reliability and efficiency of electrical systems. This innovative product combines advanced technology with user-friendly features to meet the growing demands of modern industrial and commercial environments.

One of the standout features of the EPM 3000P is its ability to provide real-time monitoring of key electrical parameters. This includes voltage, current, power, energy consumption, and power factor, all displayed on a high-resolution graphical LCD screen. The device supports a wide range of communication protocols, allowing for seamless integration into existing systems. It is compatible with Modbus, Ethernet/IP, and DNP3, enabling users to communicate and collect data from remote locations efficiently.

Another significant aspect of the EPM 3000P is its robust data logging capabilities. The device can store extensive historical data, which can be easily accessed for analysis and reporting. This feature is essential for identifying trends, diagnosing issues, and ensuring compliance with energy regulations. Customizable alarms and notifications further enhance its functionality, alerting users to potential issues before they develop into costly problems.

The EPM 3000P also emphasizes safety and protection for electrical systems. It is equipped with advanced protection features, including overvoltage, undervoltage, overcurrent, and phase loss detection. This ensures that equipment is safeguarded against electrical faults, reducing the risk of damage and downtime.

In terms of design, the EPM 3000P is both compact and rugged, making it suitable for installation in various environments. Its modular design allows for easy integration with other devices and systems, promoting scalability and future growth. The device is also compliant with international safety standards, ensuring reliability and peace of mind for users.

In conclusion, the GE EPM 3000P is a powerful tool for power management, offering users unparalleled monitoring, protection, and data analysis capabilities. With its advanced features, robust communication options, and user-friendly interface, it is positioned as an ideal solution for organizations looking to optimize their energy usage and enhance the resilience of their electrical systems. This makes it a preferred choice for industries aiming to improve operational efficiency and achieve sustainable energy practices.