Chapter 2 Electrical Installation

Figure 2.1 - Relay Connection

20

 

 

 

 

N.O.

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

N.C.

 

 

ALARM #1

 

 

 

 

 

 

Close-up of the relays on the rear panel. The relays

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shown are in the NOT energized state. (Form C relays,

22

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

rated 250V, 5A, 2 each)

 

 

 

 

 

 

 

23

 

 

 

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

N.C.

 

 

ALARM #2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 COM

THE INSTRUMENT CAN BE PROGRAMMED TO DETECT TWO ALARM LEVELS FOR THE FOLLOWING FUNCTIONS:

ƒ

LM1/LM2 Voltage

AN, BN, CN, AB, BC, CA

ƒ

LM1/LM2 Current

A, B, C, N

ƒVoltage Imbalance (One level only)

ƒVoltage Phase Reversals (One level only)

9

GE Industrial Systems

Image 14
Contents EPM 3000P All Rights Reserved Customer Service and Support Installation & O P E R a T I O N O G R a M M I N G Installation & Operation Mechanical InstallationMechanical Installation PortElectrical Installation CT Size VA Maximum Distance CT to EPM3000PListing of Connection Diagrams Electrical InstallationWith Direct Voltage and CTs With 2 CTs and 2 PTsIII. Open Delta PT Connection With 3 CTs and 2 PTsThree Phase System Wye System with PTs DUAL-PHASE Back ViewCOM RS-485 Communication InstallationRS-232C RS-485 Hookup Diagram 2 wire Half Duplex Communication InstallationRS-485 Hookup Diagram 2 wire Half Duplex Detail View EPM3000P Overview Volts AmpsEPM3000P Overview ‰ Unprotected Reset‰ Protected Reset Voltage Phase Reversal Voltage Phase Imbalance LimitAccess Operation I000222 ÖTo Print the Programming DATA, follow these steps300.0 General Procedure Overview GROUPS, Functions, and Switch PacksUsed for General Procedure OverviewPassword Standard Numeric Data EntryEntering the Programming Mode 555Programming Group 0 Global Meter Setup Function NumberGlobal Meter Setup 020I20 Pack Switch Feature Segment Position Computer Controlled Dedicated Alarm 03.0S E T I25 Input Current CT Type Full Scale Programming GroupInput Voltage PT Ratio Full Scale I50 Programming GroupVolts 4/1 PT Programming Group 2 Meter Calibration To change the CALIBRATION, follow these steps250 Programming Group 4 SET Limits & Relays 10.1LM1 LED LM2 LED ABOVE/ below Relay Level Set Limits & RelaysLM1 LED LM2 LED ABOVE/BELOW Relay Value Set Limits and Relays ÖTo program Limits or RELAYS, follow these stepsSee to Exit Phase Reversal Percent Phase ImbalancePhase Reversal & Phase Imbalance Set Limits/Relays ÖTo change the Phase Reversal settings, follow these stepsI0.0 Exiting the Programming Mode If YOU are Located AT

EPM 3000P specifications

The GE EPM 3000P is a cutting-edge power monitoring and management device designed to enhance the reliability and efficiency of electrical systems. This innovative product combines advanced technology with user-friendly features to meet the growing demands of modern industrial and commercial environments.

One of the standout features of the EPM 3000P is its ability to provide real-time monitoring of key electrical parameters. This includes voltage, current, power, energy consumption, and power factor, all displayed on a high-resolution graphical LCD screen. The device supports a wide range of communication protocols, allowing for seamless integration into existing systems. It is compatible with Modbus, Ethernet/IP, and DNP3, enabling users to communicate and collect data from remote locations efficiently.

Another significant aspect of the EPM 3000P is its robust data logging capabilities. The device can store extensive historical data, which can be easily accessed for analysis and reporting. This feature is essential for identifying trends, diagnosing issues, and ensuring compliance with energy regulations. Customizable alarms and notifications further enhance its functionality, alerting users to potential issues before they develop into costly problems.

The EPM 3000P also emphasizes safety and protection for electrical systems. It is equipped with advanced protection features, including overvoltage, undervoltage, overcurrent, and phase loss detection. This ensures that equipment is safeguarded against electrical faults, reducing the risk of damage and downtime.

In terms of design, the EPM 3000P is both compact and rugged, making it suitable for installation in various environments. Its modular design allows for easy integration with other devices and systems, promoting scalability and future growth. The device is also compliant with international safety standards, ensuring reliability and peace of mind for users.

In conclusion, the GE EPM 3000P is a powerful tool for power management, offering users unparalleled monitoring, protection, and data analysis capabilities. With its advanced features, robust communication options, and user-friendly interface, it is positioned as an ideal solution for organizations looking to optimize their energy usage and enhance the resilience of their electrical systems. This makes it a preferred choice for industries aiming to improve operational efficiency and achieve sustainable energy practices.