Heat Controller BGE-103A, BGE-123A Electrical Parts, Shroud, Motor, Compressor, Capacitor

Page 19

Disassembly Instructions

6. SHROUD

1. Remove the fan. (Refer to section 5)

2. Remove the screw which fasten the shroud.

3. Remove the shroud. (See Fig. 32)

4. Re-install the component by referring to the removal procedure, above.

FIG. 32

Electrical Parts

7. MOTOR

1.Remove the cabinet. (Refer to section 2)

2.Remove the clamp cord and disconnect a wire housing in control box. (Refer to section 3)

3.Remove the turbo fan. (Refer to section 5)

4.Remove the fan. (Refer to section 5)

5.Remove the 4 or 2 screws which fasten the motor. (See Fig. 33)

6.Remove the motor.

7.Re-install the components by referring to the removal procedure, above.

8.COMPRESSOR

1.Remove the cabinet. (Refer to section 2)

2.Discharge the refrigerant system using FreonTM Recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM . Leave the valve in place after servicing the system.

3.Disconnect the 3 leads from the compressor.

4.After purging the unit completely, unbraze the suc- tion and discharge tubes at the compressor con- nections.

5.Remove the 3 nuts and the 3 washers which fas- ten the compressor. (See Fig. 34)

6.Remove the compressor.

7.Re-instill the components by referring to the removal procedure, above.

FIG. 33

FIG. 34

9.CAPACITOR

1.Remove the control box. (Refer to section 3)

2.Remove a screw which fasten the display panel.

3.Remove 2 screws and unfold the control box. (See Fig. 35)

4.Remove the screw and the clamp which fastens the capacitor. (See Fig. 35)

5.Disconnect all the leads of capacitor terminals.

6.Re-install the components by referring to the removal procedure, above.

Cool

 

 

Energy

 

 

Saver

 

 

Fan

 

F1

 

 

F3F2 MLOWED

 

Timer

HIGH

MODE

'F

TIMER

TEMP

 

FAN

 

 

 

 

SPEED

 

 

POWER

FIG. 35

Service Manual 19

Image 19
Contents Models BGE-103A Heat CONTROLLER, INCTable of Contents Installation Safety PrecautionsOperation Keep level parallel in installing the product Do not drink water drained from air conditioner Installation requirements InstallationHow to Install InstallationItems in Installation Hardware Wall Procedure aTable below Procedure BWhen handling the air conditioner, be careful to Procedure C High Controls Operating InstructionsTimer Remote controlPower Temperature Setting Ventilation Control How to insert Batteries Vertical AIR-DIRECTION Control Cabinet Disassembly InstructionsMechanical Parts Front GrilleORIFICE, Heater Assy and Turbo FAN Air Handling PartsCompressor Electrical PartsShroud MotorThermostat Power CordCapillary Tube Refrigerating CycleCondenser EvaporatorDisassembly Instructions Pulling Vacuum Charging Wiring Diagram Schematic DiagramPiping System Troubleshooting GuideTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Troubleshooting Guide Items Models Product SpecificationsHeat CONTROLLER, INC