Disassembly Instructions
RefrigeratingCycle
CAUTION
Discharge the refrigerant system using FreonTM Recovery System.
If there is no valve to attach the recovery system, install one (such as a WATCO
12. CONDENSER |
| |
1. | Remove the cabinet. (Refer to section 2) |
|
2. | Remove the brace and the shroud cover. |
|
| (Refer to section 4) |
|
3. | Remove the 5 screws which fasten the condenser. |
|
4. | After discharging the refrigerant completely, |
|
| unbraze the interconnecting tube at the condenser | FIG. 38 |
| connections. |
|
5.Remove the condenser.
6.
(See Fig. 38)
13. EVAPORATOR
1.Remove the cabinet. (Refer to section 2)
2.Discharge the refrigerant completely.
3.Remove the 2 screws which fasten the evaporator at the left side and the right side.
4.Move the evaporator sideward carefully and then unbraze the interconnecting tube at the evaporator connectors.
5.Remove the evaporator.
6.
Cool |
|
|
Energy |
|
|
Saver |
|
|
Fan |
|
|
MODE | Timer | 'F |
TIMER | TEMP | |
| FAN | |
|
| |
|
| SPEED |
POWER
FIG. 39
14. CAPILLARY TUBE
1.Remove the cabinet. (Refer to section 2)
2.After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.
3.Remove the capillary tube.
4.
Service Manual 21