Heat Controller BGE-123A, BGE-103A service manual Troubleshooting Guide

Page 26

Troubleshooting Guide

Troubleshooting Guide

In general, possible trouble is classified in two causes.

The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit is running but cooling is ineffective

Ineffective Cooling

Check of cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged of air filter

Obstruction at air outlet

Stop of auto air-swing

Correct above trouble

Check clogging in refrigeration circuit.

Repair clogging in refrigeration circuit.

Check of outdoor coil (heat exchanger) & the fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 44.6~50˚F

Check heat load increase.

Unexpected residue

Overloaded Circuit

Check of inside gas pressure.

Adjusting of refrigerant charge

Malfunction of compressor

Replacement of compressor

26Room Air Conditioner

Image 26
Contents Heat CONTROLLER, INC Models BGE-103ATable of Contents Safety Precautions InstallationOperation Keep level parallel in installing the product Do not drink water drained from air conditioner Installation Installation requirementsItems in Installation Hardware InstallationHow to Install Procedure a WallProcedure B Table belowWhen handling the air conditioner, be careful to Procedure C High Operating Instructions ControlsTemperature Setting Remote controlPower TimerVertical AIR-DIRECTION Control How to insert BatteriesVentilation Control Front Grille Disassembly InstructionsMechanical Parts CabinetAir Handling Parts ORIFICE, Heater Assy and Turbo FANMotor Electrical PartsShroud CompressorPower Cord ThermostatEvaporator Refrigerating CycleCondenser Capillary TubeDisassembly Instructions Pulling Vacuum Charging Schematic Diagram Wiring DiagramTroubleshooting Guide Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Troubleshooting Guide Product Specifications Items ModelsHeat CONTROLLER, INC