Heat Controller HMG**X1E, HMG**F1E Important Safety Information, Nitrogen, Requirements & Codes

Page 3

Important SAFETY INFORMATION

INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if not avoided, may result in minor or moderate injury or property damage.

WARNING:

ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury or property damage.

Improper servicing could result in dangerous operation, serious injury, death or property damage.

Before servicing, disconnect all electrical power to air handler.

When servicing controls, label all wires prior to disconnecting. Reconnect wires correctly.

Verify proper operation after servicing.

WARNING:

NITROGEN

 

 

 

HEALTH

1

 

 

 

 

 

 

 

FLAMMABILITY

0

 

 

 

 

 

 

 

REACTIVITY

0

 

 

 

 

0 Minimal Hazard

1 Slight Hazard

HMG**F1E,HMG**X1E & HCG**V1E air handlers leave the factory with a nitrogen holding charge. Use caution when preparing coils for field connections. If repairs make it necessary for evacuation and charging, it should only be attempted by qualified, trained personnel thoroughly familiar with this equipment. Some local codes require licensed installation service personnel to service this type of equipment. Under no circumstances should the equipment owner attempt to install and/or service this equipment. Failure to comply with this warning could result in equipment damage, personal injury, or death.

WARNING:

PROPOSITION 65 WARNING: This product contains chemicals known to the state of California to cause cancer, birth defects or other reproductive harm.

Requirements & Codes

WARNING:

This unit must be installed in accordance with instructions outlined in this manual during the installation, service, and operation of this unit. Unqualified individuals should not attempt to interpret these instructions or install this equipment. Failure to follow safety recommendations could result in possible damage to the equipment, serious personal injury or death.

The installer must comply with all local codes and regulations which govern the installation of this type of equipment. Local codes and regulations take precedence over any recommendations contained in these instructions. Consult local building codes for special installation requirements.

This equipment contains nitrogen gas. Installation or servicing should only be performed by qualified trained personnel thoroughly familiar with this type equipment.

All electrical wiring must be completed in accordance with local, state and national codes and regulations and with the National Electric Code (ANSI/NFPA 70) or in Canada the Canadian Electric Code Part 1 CSA C.22.1.

Installation of equipment may require brazing operations.

Installer must comply with safety codes and wear appropriate safety equipment (safety glasses, work gloves, fire extinguisher, etc.) when performing brazing operations.

Install this unit only in a location and position as specified on pages 4 & 5. This unit is designed only for Indoor installations and should be located with consideration of minimizing the length of the supply and return ducts. See Tables 5 - 9 (pages 19 - 22) and the rating plate for proper circulating airflow data.

Follow all precautions in the literature, on tags, and on labels provided with the equipment. Read and thoroughly understand the instructions provided with the equipment prior to performing the installation and operational checkout of the equipment.

This air handler may be used for temporary heating of buildings or structures under construction. See the guidelines listed on page 4.

Air handler installations in a residential garage must be installed as specified on page 5.

3

Image 3
Contents AIR Handler Table of Contents Health Flammability Reactivity Important Safety InformationNitrogen Requirements & CodesMinimum Clearances Before You Install this UnitGeneral Information Locating the Air HandlerAir Filters Installation in a GaragePlenums & Air Ducts Unconditioned SpacesMounting Applications Air handler InstallationDownflow Installations Packaging RemovalHorizontal Installations Horizontal Left InstallationsHorizontal Right Installations Nitrogen Refrigerant Line ConnectionsConnecting the Linesets Orifice Removal & InstallationCondensate Drainage Example Pre-Electrical Checklist Electrical connectionsThermostat Connections Twinning Control BoardHumidifier Startup & AdjustmentsElectronic Air Cleaner EAC Heater KitsBlower Configurations Refrigerant ChargingAir Circulation Dehumidification Options Selecting Basic Heating AirflowSelecting Basic Cooling / Heat Pump Airflow Troubleshooting Unit MaintenanceFurnace Size Btuh Detail D Figures & TablesBreaker 60A Heating Element Airflow Data Dry Coil ESPAirflow Data for HMG**F1E Series Air Handlers Airflow Data for HMG**X1E Air Handlers TON HCG36V1E & HCG42V1E HCG24V1E & HCG30V1ECFM TONHCG48V1E HCG60V1E Airflow Data for HCG**V1E Air HandlersHCG24V1E HCG30V1E HCG36V1E HCG42V1ESingle Stage Control Board Electrical diagrams & DataFixed Speed Motor Control Board Handler Wiring Diagram for HMG**F1E Series AirSeries Air Handler Air Handler with Fixed Speed High Efficiency MotorHCG**V1E Series Air Handler Wiring Diagram forHMG**F1E Series MCA MOPH6HK Models Number Control Signal & Mode Operation Total KW Board ActionControl Board Operation Air Handler ModelAUX Heat FAN Installation Address Installer Name

HMG**X1E, HCG**V1E, HMG**F1E specifications

The Heat Controller series, comprising models HMG**F1E, HCG**V1E, and HMG**X1E, showcases advanced heating and cooling technologies designed for optimal comfort and energy efficiency in residential and commercial settings. Each model is equipped with a range of features that cater to diverse user needs while maintaining excellent performance.

The HMG**F1E model stands out with its sleek design and compact size, making it ideal for smaller spaces. It utilizes inverter technology, which enables the unit to operate at variable speeds for greater efficiency and reduced energy consumption. This model also comes with a user-friendly remote control, allowing for easy adjustments of temperature settings and operational modes without the need to manually interact with the unit itself. The HMG**F1E is equipped with a filtration system that improves indoor air quality by removing dust and allergens, providing a more comfortable living environment.

In contrast, the HCG**V1E model is designed with versatility in mind, offering both heating and cooling functions. This unit features a programmable thermostat, allowing users to set their preferred temperatures for different times of the day. The HCG**V1E is manufactured with durable materials that ensure longevity and reliability under various weather conditions. Additionally, it provides whisper-quiet operation, ensuring minimal disturbance to indoor activities. The energy-efficient operation and smart climate control technology contribute to significant savings on energy bills.

Finally, the HMG**X1E model is known for its cutting-edge smart technology integration. This model can be connected to smart home systems, enabling users to control the unit from their smartphones or tablets. It features advanced sensors that detect occupancy and adjust heating and cooling accordingly, optimizing energy usage in real-time. The HMG**X1E also incorporates an eco-friendly refrigerant, aligning with modern environmental standards while delivering exceptional performance.

Overall, the Heat Controller series with models HMG**F1E, HCG**V1E, and HMG**X1E redefine comfort and efficiency. With their combination of innovative technologies, user-friendly features, and sustainable designs, they are perfect for anyone seeking reliable temperature control solutions for their spaces.