Remove old air conditioner from existing wall sleeve.
Clean the interior of an existing sleeve. (Do not disturb seals.)

3.2INSTALLATION

CAUTION

Installing the FRIEDRICH USC sleeve ensures optional performances of the unit.

If you decide to keep the existing wall sleeve, you have to redirect the louvers at the back of the wall sleeve. Refer to FIG. 23 on p15. The use of pliers is recommended. If you DO NOT redirect, you run the risk of poor performance or premature product failure. This is not covered under the terms of the FRIEDRICH warranty.

Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.

ITEMS IN INSTALLATION HARDWARE

You may not need all parts in the kit. Discard unused parts

ITEM (inches)

 

Qty.

Plastic grille

 

263/4 x 161/2

1

 

Vertical insulation strip

 

159/16 x 13/8 x 13/8

1

 

Around Insulation Strips

 

671/8 x 13/8 x 25/32

1

 

 

5927/32 x 13/8 x 13/8

1

 

 

 

 

Horizontal Insulation Strip

 

237/32 x 13/8 x 13/16

1

 

Support Block

 

13/4 x 13/8 x 45/16

2

 

Baffle

 

14 x 41/2 x 1/8

1

 

Shim

 

1113/16 x 1 x 3/4

2

 

Trim Frame

 

 

2

 

Washer Screw

 

 

4

 

Nuts(Plastic)

 

 

4

 

Grille Rear

 

 

1

 

HOW TO INSTALL

1 Before installing the unit, identify the existing wall sleeve

from the list below.

 

 

 

 

 

 

 

Brand

Wall Sleeve Dimensions (inches)

Width

Height

Depth

 

White-Westinghouse

 

 

16, 17-1/2

Frigidaire

25-1/2

15-1/4

or 22

Carrier (52F series)

 

 

 

 

 

General Electric

26

15-5/8

16-7/8

/Hotpoint

 

 

 

Whirlpool

25-7/8

16-1/2

17-1/8

or 23

 

 

 

Fedders/Emerson

27

16-3/4

16-3/4

Friedrich WSC

or 19-3/4

 

 

FRIEDRICH USC

25-7/8

15-17/32

16-23/32

Emerson/Fedders

26-3/4

15-3/4

15

Carrier (51S Series)

25-3/4

16-7/8

18-5/8

NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner.

2

3

Wall sleeve must be securely fastened in wall before

4 installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.

Prepare the wall sleeve for installation of the unit. If you

5 plan to use your existing wall sleeve, and it is not FRIEDRICH, use procedure B or C below.

Procedure

Brand

Depth(inches)

A(page 16)

FRIEDRICH USC

16-23/32

 

White-Westinghouse

16, 17-1/2

 

Frigidaire Carrier

 

or 22

B

(52F series)

 

General Electric

 

(pages 17~18)

16-7/8

/Hotpoint

 

 

 

Whirlpool

17-1/8 or 23

 

Carrier (51S series)

18-5/8

C

Fedders/Emerson

16-3/4

Friedrich WSC

or 19-3/4

(pages 19)

Emerson/Fedders

15

 

 

 

 

6 Install new unit into wall sleeve.

CAUTION: When installation is completed, replacement unit MUST have a rearward slope as shown. To achieve 1/4" slope, remove the backing from the 11-13/16" shim strips and attach them as shown below in Fig. 19. Place the higher portion of shim to the front of the rib on base of wall sleeve.

1" high

3/4" High

 

 

UNIT

Wall Sleeve

Shim

FRONT

 

 

 

6"

1/4"

 

6"

 

SHIM PLACEMENT

UNIT INSTALLATION

 

 

FIG. 19

—13

Image 13
Contents Heat CONTROLLER, INC Contents Remark Specifications 1.3.1 for BG-103AControl Locations FeaturesCooling only Model Operation VentilationFront Grille Mechanical PartsCabinet Control BOXORIFICE, and Turbo FAN AIR Handling PartsCompressor Electrical PartsCapacitor Thermistor Power CordCondenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Installation Hardware Installation RequirementsElectrical Service Required ToolsItems in Installation Hardware HOW to InstallToassembletrim,tpthetabofeachpiece Procedure aTop View Procedure BWall Wall sleeve inches Procedure CParts and Installation Piping System Outside DimensionsTroubleshooting Guide Fails to Start Complaint Cause Remedy Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Circuit Diagram Exploded View Description QTY Remark Replacement Parts ListHeat CONTROLLER, INC