3.2INSTALLATION
CAUTION
Installing the FRIEDRICH USC sleeve ensures optional performances of the unit.
If you decide to keep the existing wall sleeve, you have to redirect the louvers at the back of the wall sleeve. Refer to FIG. 23 on p15. The use of pliers is recommended. If you DO NOT redirect, you run the risk of poor performance or premature product failure. This is not covered under the terms of the FRIEDRICH warranty.
•Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused parts
ITEM (inches) |
| Qty. | ||
Plastic grille |
| 263/4 x 161/2 | 1 |
|
Vertical insulation strip |
| 159/16 x 13/8 x 13/8 | 1 |
|
Around Insulation Strips |
| 671/8 x 13/8 x 25/32 | 1 |
|
| 5927/32 x 13/8 x 13/8 | 1 |
| |
|
|
| ||
Horizontal Insulation Strip |
| 237/32 x 13/8 x 13/16 | 1 |
|
Support Block |
| 13/4 x 13/8 x 45/16 | 2 |
|
Baffle |
| 14 x 41/2 x 1/8 | 1 |
|
Shim |
| 1113/16 x 1 x 3/4 | 2 |
|
Trim Frame |
|
| 2 |
|
Washer Screw |
|
| 4 |
|
Nuts(Plastic) |
|
| 4 |
|
Grille Rear |
|
| 1 |
|
HOW TO INSTALL
1 Before installing the unit, identify the existing wall sleeve | ||||
from the list below. |
|
|
| |
|
|
|
| |
Brand | Wall Sleeve Dimensions (inches) | |||
Width | Height | Depth | ||
| ||||
|
| 16, | ||
Frigidaire | ||||
or 22 | ||||
Carrier (52F series) |
|
| ||
|
|
| ||
General Electric | 26 | |||
/Hotpoint | ||||
|
|
| ||
Whirlpool | ||||
or 23 | ||||
|
|
| ||
Fedders/Emerson | 27 | |||
Friedrich WSC | or | |||
|
| |||
FRIEDRICH USC | ||||
Emerson/Fedders | 15 | |||
Carrier (51S Series) |
NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner.
2
3
Wall sleeve must be securely fastened in wall before
4 installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.
Prepare the wall sleeve for installation of the unit. If you
5 plan to use your existing wall sleeve, and it is not FRIEDRICH, use procedure B or C below.
Procedure | Brand | Depth(inches) | |
A(page 16) | FRIEDRICH USC | ||
| 16, | ||
| Frigidaire Carrier | ||
| or 22 | ||
B | (52F series) | ||
| |||
General Electric |
| ||
(pages 17~18) | |||
/Hotpoint | |||
|
| ||
| Whirlpool | ||
| Carrier (51S series) | ||
C | Fedders/Emerson | ||
Friedrich WSC | or | ||
(pages 19) | |||
Emerson/Fedders | 15 | ||
| |||
|
|
|
6 Install new unit into wall sleeve.
CAUTION: When installation is completed, replacement unit MUST have a rearward slope as shown. To achieve 1/4" slope, remove the backing from the
1" high | 3/4" High |
|
| UNIT | Wall Sleeve |
Shim | FRONT |
|
|
| |
6" | 1/4" |
|
6" |
| |
SHIM PLACEMENT | UNIT INSTALLATION | |
|
| FIG. 19 |