Heat Controller BG-103A service manual Procedure a, Toassembletrim,tpthetabofeachpiece

Page 14

PROCEDURE A

1

If you are using the new sleeve (optionally

 

supplied with your unit),skip to step 3.

Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and

15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

FIG.20

2 Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressing into the square holes of the rear flanges.Fasten the bracket to the upside of the wall sleeve using the washer screw. The bracket prevents the unit from leaving the sleeve.

Bracket

 

Bracket

Fasten the screws and the bracket

or

FIG.21

3 Remove the backing from the Vertical Insulation strip 159/16 x 13/8 x 13/8 and attach that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below.

Indoor

Outdoor

Around Insulation

 

9 1/2"

6"

 

FIG. 22

4

Install the new unit into the wall sleeve.

5

Toassembletrim,tpthetabofeachpiece

into the slot of the other piece as shown below.

Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.

Trim (2 ea)

Wall

FIG.23

CAUTION

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.

Make sure air conditioner does not fall during removal.

If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.

—14

Image 14
Contents Heat CONTROLLER, INC Contents Specifications 1.3.1 for BG-103A RemarkCooling only Model Operation FeaturesControl Locations VentilationCabinet Mechanical PartsFront Grille Control BOXAIR Handling Parts ORIFICE, and Turbo FANCapacitor Electrical PartsCompressor Power Cord ThermistorEvaporator Refrigeration CycleCondenser Capillary TubePage Pulling Vacuum Electrical Service Installation RequirementsInstallation Hardware Required ToolsHOW to Install Items in Installation HardwareProcedure a Toassembletrim,tpthetabofeachpieceProcedure B Top ViewWall Procedure C Wall sleeve inchesParts and Installation Outside Dimensions Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Name Plate Rating Minimum MaximumComplaint Cause Remedy Circuit Diagram Exploded View Replacement Parts List Description QTY RemarkHeat CONTROLLER, INC