Heat Controller BG-103A Features, Control Locations, Cooling only Model Operation, Ventilation

Page 4

1.4 FEATURES

Designed for cooling only.

Powerful and quiet cooling.

Top-down chassis for the simple installation and service.

1.5 CONTROL LOCATIONS

1.5.1COOLING ONLY MODEL

• OPERATION

FAN SPEED

Side air-intake, side cooled-air discharge.

Built in adjustable THERMISTOR and THERMOSTAT.

Washable one-touch filter.

Compact size.

Every time you push this button, it advances the setting as follows: {High Low Med High}

Cool

F1 LOW

Energy

F2 MED

F3 HIGH

Saver

 

Fan

Timer TEMP

FAN

MODE TIMER SPEED

TIMER

- SHUT-OFF TIME

REMOTE CONTROL SIGNAL RECEIVER

'F

TEMPERATURE SETTING

Use this button to automatically control the temperature of the room.

The temperature can be set within a range of 60°F to 86°F by increments of 1°F.

The setting appears in the display.

POWER POWER

To turn the air conditioner ON, push this button.

To turn the air conditioner OFF, push the button again.

This button takes priority over any other button.

When you first turn it on, the unit is in cool mode, High fan speed, Temperature setting at 72°F.

You will usually use shut-off time while you sleep.

If unit is running, use Timer to set number of hours until shut-off.

For your sleeping comfort, once Time is set, the Temperature setting will raise 2°F after 30 min., and once again after another 30 min.

Push Timer button to advance setting from 1Hour 2Hours ... 12Hours maximum.

-START TIME

If unit is off, use Timer to set number of hours before unit starts.

Push Timer button to advance setting from 1Hour 2Hours ... 12Hours maximum.

MODE

-Push this button to shift mode of operation from COOL ENERGY SAVER FAN.

-COOL:

Fan runs continually for normal cooling operation.

-ENERGY SAVER:

The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed.

-FAN:

Fan-only operation.

VENTILATION

Push the lever to the "CLOSE" position to cool, heat or recirculate room air only.

Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room.

This feature is best used in conjunction with the FAN ONLY position.

CAUTION

 

When the air conditioner has been operating in the

cooling and is turned off or set to the fan

only position,

wait at least 3 minutes before resetting to the cooling

operation again.

PULL OPEN / PUSH CLOSE

4

Image 4
Contents Heat CONTROLLER, INC Contents Specifications 1.3.1 for BG-103A RemarkFeatures Control LocationsCooling only Model Operation VentilationMechanical Parts Front GrilleCabinet Control BOXAIR Handling Parts ORIFICE, and Turbo FANCompressor Electrical PartsCapacitor Power Cord ThermistorRefrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum Installation Requirements Installation HardwareElectrical Service Required ToolsHOW to Install Items in Installation HardwareProcedure a Toassembletrim,tpthetabofeachpieceProcedure B Top ViewWall Procedure C Wall sleeve inchesParts and Installation Outside Dimensions Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Name Plate Rating Minimum MaximumComplaint Cause Remedy Circuit Diagram Exploded View Replacement Parts List Description QTY RemarkHeat CONTROLLER, INC