Heat Controller BG-103A service manual Fails to Start

Page 21

Fails to Start

Check power source.

Check control switch setting.

Only compressor fails to start.

Drop in power voltage.

Defective compressor capacitor.

Check capacitor.

Replacement.

Check circuit breaker and fuse.

Gas leakage at feeler bulb of thermostat

Check control switch.

Only fan fails to start.

Improper wiring.

Improper thermostat setting Defect of fan motor capacitor.

Loose terminal connection.

Irregular motor resistance ( ).

Irregular motor insulation

( ). Improper wiring

Replacement of fan motor

Irregular motor resistance ()

Irregular motor insulation ( )

Replacement of compressor (Motor damaged)

Regular but fails to start

Replacement of compressor (locking of rotor, metal)

21

Image 21
Contents Heat CONTROLLER, INC Contents Remark Specifications 1.3.1 for BG-103AControl Locations FeaturesCooling only Model Operation VentilationFront Grille Mechanical PartsCabinet Control BOXORIFICE, and Turbo FAN AIR Handling PartsElectrical Parts CompressorCapacitor Thermistor Power CordCondenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Installation Hardware Installation RequirementsElectrical Service Required ToolsItems in Installation Hardware HOW to InstallToassembletrim,tpthetabofeachpiece Procedure aTop View Procedure BWall Wall sleeve inches Procedure CParts and Installation Piping System Outside DimensionsTroubleshooting Guide Fails to Start Complaint Cause Remedy Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Circuit Diagram Exploded View Description QTY Remark Replacement Parts ListHeat CONTROLLER, INC