Heat Controller BG-103A Installation Requirements, Installation Hardware, Electrical Service

Page 12

3. INSTALLATION

3.1 INSTALLATION REQUIREMENTS

If you use an existing wall sleeve, you should measure its

dimensions.

Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good structural condition and have a compatible rear grille in order to securely attach the new air conditioner. (FIG. 18A)

With the FRIEDRICH USC sleeve, you can maintain the best performance of the new air conditioner. (FIG. 18B)

INSTALLATION HARDWARE

1

2

4

 

5

 

 

 

2 Size options

 

8

6

 

 

9

3

 

 

 

7

 

2 Size options

20-3/32"

(511 mm)

Air Conditioner

24"(610 mm)

14-13/32"

(366 mm)

18-15/32"(468 mm)

FIG. 18A

ITEM

NAME OF PARTS

Q'TY

 

PLASTIC GRILLE

1

 

VERTICAL INSULATION STRIP

1

 

AROUND INSULATION STRIPS

2

 

HORIZONTAL INSULATION STRIP

1

 

SUPPORT BLOCK

2

 

BAFFLE

1

 

TRIM FRAME

2

 

SHIM

2

 

PLASTIC NUTS AND WASHER SCREWS

4

aluminum metal grille

FRIEDRICH USC Wall Sleeve

25-7/8"

(656 mm)

15-17/32"

(394 mm)

16-23/32"

(425 mm)

FIG. 18B

CAUTION

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are

needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

ELECTRICAL SERVICE

Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON for storage and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.

Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.

Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.

Make sure air conditioner does not fall during installation.

REQUIRED TOOLS:

 

• Tight Fitting gloves

3/8-inch open end

• Standard screwdriver

wrench or adjustable

wrench

• Phillips screwdriver

1/4-inch hex socket

• Pliers

and ratchet

• Sharp knife

• Tape measure

 

• Electric drill

 

1/4-inch drill bit

 

 

—12

Image 12
Contents Heat CONTROLLER, INC Contents Specifications 1.3.1 for BG-103A RemarkFeatures Control LocationsCooling only Model Operation VentilationMechanical Parts Front GrilleCabinet Control BOXAIR Handling Parts ORIFICE, and Turbo FANElectrical Parts CompressorCapacitor Power Cord ThermistorRefrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum Installation Requirements Installation HardwareElectrical Service Required ToolsHOW to Install Items in Installation HardwareProcedure a Toassembletrim,tpthetabofeachpieceProcedure B Top ViewWall Procedure C Wall sleeve inchesParts and Installation Outside Dimensions Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Name Plate Rating Minimum MaximumComplaint Cause Remedy Circuit Diagram Exploded View Replacement Parts List Description QTY RemarkHeat CONTROLLER, INC