Heat Controller BG-103A service manual Troubleshooting Guide

Page 20

4.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two causes.

The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit is running but cooling is ineffective

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged air filter

Obstruction at air outlet

Stop auto air-swing

Correct above troubles

Check clogging in refrigeration circuit.

Repair clogging in refrigeration circuit.

Check outdoor coil

(heat exchanger) & the fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 44.6~50˚F

Check heat load increase.

Unexpected residue

Overloaded Circuit

Check inside gas pressure.

Adjusting of refrigerant charge

Malfunction of compressor

Replacement of compressor

20

Image 20
Contents Heat CONTROLLER, INC Contents Specifications 1.3.1 for BG-103A RemarkFeatures Control LocationsCooling only Model Operation VentilationMechanical Parts Front GrilleCabinet Control BOXAIR Handling Parts ORIFICE, and Turbo FANCapacitor Electrical PartsCompressor Power Cord ThermistorRefrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum Installation Requirements Installation HardwareElectrical Service Required ToolsHOW to Install Items in Installation HardwareProcedure a Toassembletrim,tpthetabofeachpieceProcedure B Top ViewWall Procedure C Wall sleeve inchesParts and Installation Outside Dimensions Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Name Plate Rating Minimum MaximumComplaint Cause Remedy Circuit Diagram Exploded View Replacement Parts List Description QTY RemarkHeat CONTROLLER, INC