Haier SAP-K18AM, KC18AGH instruction manual Remote Control Unit Functions

Page 10

Operation and Maintenance

4. OPERATION OF WIRELESS REMOTE CONTROL UNIT

4.2 Remote Control Unit (Functions)

Signal Transmitter

Display

 

ON/OFF operation button

 

 

 

 

 

MODE operation button

EG

 

 

 

TEMP. setting button

 

 

 

 

 

 

 

 

 

 

 

TEMP button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN SPEED Selector button

 

 

 

 

 

 

 

 

 

 

 

SWING button

 

 

 

 

 

 

 

 

 

 

 

CLOCK button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMER ON button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOW button

 

 

 

 

 

 

 

 

 

 

 

TIMER OFF button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TURBO button

 

 

 

 

 

 

 

 

 

LIGHT button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmitter

When you press the buttons on the remote control unit, the OPER

 

 

 

mark appears in the display to transmit the setting changes to

 

 

 

the receiver in the air conditioner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

Information on the operating conditions is displayed while the

 

 

 

remote control unit is switched on. If the unit is turned off, only

 

 

 

CLOCK and TEMP was displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF operation

This button is for turning the air conditioner ON and OFF.

 

 

 

 

 

 

 

 

 

 

MODE selector button To select “AUTO” “COOL”, “DRY” “FAN” or “HEAT” mode.

 

 

(AUTO)

 

: When choosed this setting, the air conditioner calculates

 

 

 

 

thedifference between the thermostat setting and the room

 

 

 

 

temperature and automatically switches to the “COOL” or

 

 

 

 

“HEAT” mode as appropriate.

 

 

 

 

(COOL)

 

: The air conditioner makes the room cooler.

 

 

 

 

 

 

 

 

(DRY)

 

: The air conditioner reduces the humidity in the room.

 

 

(FAN)

 

: The air conditioner run the indoor fan only.

 

 

(HEAT)

 

: The air conditioner makes the room warmer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(+) / (-) setting

 

+ : Press the (+) button to increase set temperature, continue

 

 

buttons

 

press 2 seconds for fast increasing set temperature.

 

-: Press the (-) button to reduce set temperature, continue press 2 seconds for fast reducing set temperature.

LOCK / UNLOCK

: Press the - + button at the same time to lock or unlock

button

wireless remote controller.

 

 

TIMER ON button

: The air conditioner starts at the set time.

 

 

TIMER OFF button

: The air conditioner stops at the set time.

8

Image 10
Contents 85S-6-4181-002-00-0 Split System Air Conditioner Contents Operation and Maintenance Operation and Maintenance Heat Pump Model Only Working Temperature Range Conditions of Unit Cant Operate NormallyNames and Fuctions of Each Part Indoor UnitOperation of Wireless Remote Control Unit Remote Control Unit DisplayRemote Control Unit Functions Auto How it Works?Using the General Operation StepSetting procedure Using the 24-Hour on or OFF TimerTimer OFF mode Example Cooling and DRY Mode Sleep Mode is used for saving energy Using the Sleep OperationHeating Mode DRY Operation How it works? Using of the Special Features & RemarksSetting OFF the displayer indicator light Auto Operation How it works? Blow OperationSwing Operation How it works? Using the Remote Control Unit Fig How to Install BatteriesEmergency Operation Fig Take off the front panel Clean and CareClean the Front Panel WashingCheck Before You Use Cleaning the Air FiltersCleaning Maintain After UseTroubleshooting PhenomenonPhenomenon Troubleshooting Troubleshooting Indoor Unit Installation Position Selection Basic Requirements for Installation PositionOutdoor Unit Installation Position Selection Earthing Requirements Others Safety Requirements for Electric AppliancesWrong connection, may cause fire Space to the wall Installation Diension DiagramSpace to the ceiling Space to the obstructionInstall the Piping Hole Install Indoor UnitInstall the Real Panel Install the Water Drainage PipeConnect Indoor and Outdoor Electric Wire Wiring InstructionsWire Length and Diameter Wiring System DiagramHow to Install the Indoor Unit Install Outdoor Unit Wiring Instructions for the Outdoor UnitUse of The Flaring Method Flaring Procedure With a Flare ToolRefrigerant Tubing DeburringInsulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinish the Installation Taping the TubesAir Purging AIR Purging with a Vacuum Pump for Test RUNAir Purging How to install AccessoriesTubing Length Pump Down Procedure What is Pump Down?Pump Down Check After Installation Check After Installation and Test RUNTest Operation

KC18AGH, SAP-K18AM specifications

The Haier SAP-K18AM and KC18AGH are part of Haier's innovative line of air conditioning solutions designed to provide efficient cooling and exceptional comfort in various environments. These models stand out for their blend of modern technology, user-friendly features, and energy efficiency.

One of the main features of the Haier SAP-K18AM is its powerful cooling capacity, which enables it to quickly lower indoor temperatures, making it ideal for larger spaces or warmer climates. With a cooling capacity of 18000 BTU, this model ensures that even during the hottest summer days, users can enjoy a refreshing indoor atmosphere. The unit operates quietly, allowing for peaceful relaxation or focused work without the disturbance of loud compressor noises.

The KC18AGH model is equipped with advanced inverter technology that adjusts the compressor speed according to the cooling demand. This feature not only enhances energy efficiency but also helps to maintain a consistent temperature throughout the space. The inverter technology significantly reduces electricity consumption compared to non-inverter models, making it an environmentally friendly choice.

Both models come with a range of convenient features, including multiple cooling and fan speed options, sleep mode, and a programmable timer. The sleep mode function gradually increases the temperature at night, ensuring a comfortable sleep environment while saving energy. The programmable timer allows users to set the air conditioning unit to operate only when needed, further optimizing energy use.

Additionally, the Haier SAP-K18AM and KC18AGH are designed with user comfort in mind. They come with an easy-to-use remote control, allowing for effortless adjustments from across the room. The units also include a self-cleaning feature that helps reduce mold and bacteria buildup, ensuring that the air quality remains high.

In conclusion, the Haier SAP-K18AM and KC18AGH air conditioners represent cutting-edge technology and design. With powerful cooling capabilities, energy-efficient inverter technology, and a suite of user-friendly features, these models are ideal for anyone looking to improve the comfort and quality of their indoor environment. Whether for residential or commercial use, Haier continues to set the standard in reliable and effective air conditioning solutions.