Haier SAP-K18AM, KC18AGH Install Indoor Unit, Install the Real Panel, Install the Piping Hole

Page 26

Installation Service

9.INSTALL INDOOR UNIT

9.1Install the Real Panel

1. Always mount the rear panel

Wall

Mark on the

Gradienter

Wall

horizontally. Due to the water tray

middle of it

 

 

 

of indoor unit has been adopted the

Space

 

 

Space

both-way drainage design, the

to the

 

 

to the

wall

 

 

wall

outlet of water tray should be

150mm

 

 

150mm

adjusted slightly down when

above

 

 

above

 

 

 

 

installing, that is taking the outlet of

 

 

 

 

the water tray as the center of a

Left

 

 

Right

circle, the included angle between

ij 55mm

 

 

ij 55mm

the evaporator and level should be

(Rear piping hole)

(Rear piping hole)

0 or more, that is good for

 

 

Fig.11

 

condensing water drainage.

 

 

 

2.Fix the rear panel on the wall with screws. (Where is pre-covered with

plastic granula)

 

Right-rear

Left

tubing

3. Be sure that the rear panel has

been fixed firmly enough to support

tubing

(recommended)

the weight of an adult of 60kg,

 

 

further more, the weight should be

 

 

evenly shared by each screw.

Left-rear

Right tubing

 

tubing

9.2 Install the Piping Hole

Fig.12

 

1. Determine which side of the unit you should

 

 

 

 

make the hole for tubing and wiring. (Fig.12)

 

 

 

 

2. Make the piping hole (Ɏ55) in the wall at a

 

 

 

 

slight downward slant to the outdoor side.

Indoor

 

 

Outdoor

(Fig.13)

 

 

 

 

 

Before making the hole, check

Wall pipe

 

 

NOTE

Seal pad

 

 

carefully that no studs or pipes

 

 

 

 

 

 

 

 

 

 

 

are directly run behind the spot

 

 

 

 

 

 

to be cut.

 

 

 

Ø55

 

 

Also avoid areas where

 

 

 

Protection

 

 

electrical wiring or conduits

 

 

 

 

 

are located.

 

 

 

sleeve pipe

3. Insert the piping-hole sleeve into the hole

Fig.13

 

to prevent the connection piping and wiring

 

 

 

 

from being damaged when passing through

 

 

 

 

the hole.

 

 

 

 

9.3 Install the Water Drainage Pipe

1.Drainage hose must be placed at downward slant downward slant for smooth drainage.

2.Do not wrench, bend or heave the drainage hose or flood its end by water. (Fig.14)

3.The prolonged drainage hose should be covered by heat insulation material when through indoor.

Wrenched

Bent

Flooded

Fig.14

24

Image 26
Contents 85S-6-4181-002-00-0 Split System Air Conditioner Contents Operation and Maintenance Operation and Maintenance Heat Pump Model Only Working Temperature Range Conditions of Unit Cant Operate NormallyNames and Fuctions of Each Part Indoor UnitOperation of Wireless Remote Control Unit Remote Control Unit DisplayRemote Control Unit Functions Auto How it Works?Using the General Operation StepTimer OFF mode Example Using the 24-Hour on or OFF TimerSetting procedure Heating Mode Using the Sleep OperationCooling and DRY Mode Sleep Mode is used for saving energy DRY Operation How it works? Using of the Special Features & RemarksSetting OFF the displayer indicator light Auto Operation How it works? Blow OperationSwing Operation How it works? Emergency Operation Fig How to Install BatteriesUsing the Remote Control Unit Fig Take off the front panel Clean and CareClean the Front Panel WashingCheck Before You Use Cleaning the Air FiltersCleaning Maintain After UseTroubleshooting PhenomenonPhenomenon Troubleshooting Troubleshooting Outdoor Unit Installation Position Selection Basic Requirements for Installation PositionIndoor Unit Installation Position Selection Wrong connection, may cause fire Safety Requirements for Electric AppliancesEarthing Requirements Others Space to the wall Installation Diension DiagramSpace to the ceiling Space to the obstructionInstall the Piping Hole Install Indoor UnitInstall the Real Panel Install the Water Drainage PipeConnect Indoor and Outdoor Electric Wire Wiring InstructionsWire Length and Diameter Wiring System DiagramHow to Install the Indoor Unit Install Outdoor Unit Wiring Instructions for the Outdoor UnitUse of The Flaring Method Flaring Procedure With a Flare ToolRefrigerant Tubing DeburringInsulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinish the Installation Taping the TubesAir Purging AIR Purging with a Vacuum Pump for Test RUNAir Purging Tubing Length AccessoriesHow to install Pump Down What is Pump Down?Pump Down Procedure Test Operation Check After Installation and Test RUNCheck After Installation

KC18AGH, SAP-K18AM specifications

The Haier SAP-K18AM and KC18AGH are part of Haier's innovative line of air conditioning solutions designed to provide efficient cooling and exceptional comfort in various environments. These models stand out for their blend of modern technology, user-friendly features, and energy efficiency.

One of the main features of the Haier SAP-K18AM is its powerful cooling capacity, which enables it to quickly lower indoor temperatures, making it ideal for larger spaces or warmer climates. With a cooling capacity of 18000 BTU, this model ensures that even during the hottest summer days, users can enjoy a refreshing indoor atmosphere. The unit operates quietly, allowing for peaceful relaxation or focused work without the disturbance of loud compressor noises.

The KC18AGH model is equipped with advanced inverter technology that adjusts the compressor speed according to the cooling demand. This feature not only enhances energy efficiency but also helps to maintain a consistent temperature throughout the space. The inverter technology significantly reduces electricity consumption compared to non-inverter models, making it an environmentally friendly choice.

Both models come with a range of convenient features, including multiple cooling and fan speed options, sleep mode, and a programmable timer. The sleep mode function gradually increases the temperature at night, ensuring a comfortable sleep environment while saving energy. The programmable timer allows users to set the air conditioning unit to operate only when needed, further optimizing energy use.

Additionally, the Haier SAP-K18AM and KC18AGH are designed with user comfort in mind. They come with an easy-to-use remote control, allowing for effortless adjustments from across the room. The units also include a self-cleaning feature that helps reduce mold and bacteria buildup, ensuring that the air quality remains high.

In conclusion, the Haier SAP-K18AM and KC18AGH air conditioners represent cutting-edge technology and design. With powerful cooling capabilities, energy-efficient inverter technology, and a suite of user-friendly features, these models are ideal for anyone looking to improve the comfort and quality of their indoor environment. Whether for residential or commercial use, Haier continues to set the standard in reliable and effective air conditioning solutions.