Haier KC18AGH, SAP-K18AM instruction manual Tubing Length, Accessories, How to install

Page 35

Installation Service

10.INSTALL OUTDOOR UNIT

10.4Tubing Length

Install unit within the maximum elevation different (H) above or below the outdoor unit and within a tatal tubing length (L) from the outdoor unit as detailed showed in Table 4 and Fig.37.

INDOOR

UNIT

Elevation difference (H)

Tubing length (L)

OUTDOOR

UNIT

 

 

 

 

 

Fig. 37

Table 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Allowable Tubing

Limit of Tubing

Limit of Elevation

 

Required Amount of

 

Model

Length at Shipment

Length (L)

Different (H)

 

Additional Refrigerant

 

 

(m)*1

(m)

(m)

 

(g/m)*2

 

C18AM

7.5

25

7

 

30

 

 

 

 

 

 

 

 

C18AGH

5.0

25

7

 

30

 

 

 

 

 

 

 

*1 Standard tubing length is 5m for C18AGH & 7.5m for C18AM.

*2 If total tubing length becomes 5m / 7.5m to 25m, charge additional refrigerant (R22) acording to table above. No additional charge of compressor oil is necessary.

10.5Outdoor Condensation Drainage (Heat Pump model only)

When the unit is heating and cooling type, the condensing water and defrosting water can be drained out reliably through the drainage pipe.

How to install:

Install the outdoor drain nozzle in Ø 25 hole on the base plate, and joint the drain pipe to the drain nozzle, so that the waste water formed in the outdoor unit can be drained out to a proper place.(Fig.38)

Chasis

Drain Nozzle

Fig. 38

10.6 Accessories

Table 5 listed the accessories supplied with the unit.

Table 5

Parts

Silver Ion filter

Remote control unit

Signal control wire

Power connection wire

Figure

FAN OPER

C

ONOFF

ON/OFF MODE

- +

FAN

CLOCK

BLOW TEMP

TURBO SLEEP LIGHT

#

Q’ty

Parts

Figure

Q’ty

Parts

Figure

Q’ty

2

AAA alkaline

 

2

Tapping

4.2 x 25 mm

10

battery

 

screw

 

 

 

 

 

 

Remote control

 

 

 

 

 

1

holder

 

1

Ins. tube

 

1

 

(Optional Part)

 

 

 

 

 

1

Drain nozzle*

#

1

Putty

 

1

 

 

1

Drain cap*

#

3

Flare Nut

0

1

 

*Packed in the outdoor unit

#Heat pump model only

33

Image 35
Contents 85S-6-4181-002-00-0 Split System Air Conditioner Contents Operation and Maintenance Operation and Maintenance Heat Pump Model Only Conditions of Unit Cant Operate Normally Working Temperature RangeIndoor Unit Names and Fuctions of Each PartRemote Control Unit Display Operation of Wireless Remote Control UnitRemote Control Unit Functions How it Works? AutoStep Using the General OperationTimer OFF mode Example Using the 24-Hour on or OFF TimerSetting procedure Heating Mode Using the Sleep OperationCooling and DRY Mode Sleep Mode is used for saving energy Auto Operation How it works? Blow Operation Using of the Special Features & RemarksSetting OFF the displayer indicator light DRY Operation How it works?Swing Operation How it works? Emergency Operation Fig How to Install BatteriesUsing the Remote Control Unit Fig Washing Clean and CareClean the Front Panel Take off the front panelMaintain After Use Cleaning the Air FiltersCleaning Check Before You UsePhenomenon TroubleshootingPhenomenon Troubleshooting Troubleshooting Outdoor Unit Installation Position Selection Basic Requirements for Installation PositionIndoor Unit Installation Position Selection Wrong connection, may cause fire Safety Requirements for Electric AppliancesEarthing Requirements Others Space to the obstruction Installation Diension DiagramSpace to the ceiling Space to the wallInstall the Water Drainage Pipe Install Indoor UnitInstall the Real Panel Install the Piping HoleWiring Instructions Connect Indoor and Outdoor Electric WireWiring System Diagram Wire Length and DiameterHow to Install the Indoor Unit Wiring Instructions for the Outdoor Unit Install Outdoor UnitDeburring Flaring Procedure With a Flare ToolRefrigerant Tubing Use of The Flaring MethodTaping the Tubes Connecting Tubing between Indoor and Outdoor UnitsFinish the Installation Insulation of Refrigerant TubingAIR Purging with a Vacuum Pump for Test RUN Air PurgingAir Purging Tubing Length AccessoriesHow to install Pump Down What is Pump Down?Pump Down Procedure Test Operation Check After Installation and Test RUNCheck After Installation

KC18AGH, SAP-K18AM specifications

The Haier SAP-K18AM and KC18AGH are part of Haier's innovative line of air conditioning solutions designed to provide efficient cooling and exceptional comfort in various environments. These models stand out for their blend of modern technology, user-friendly features, and energy efficiency.

One of the main features of the Haier SAP-K18AM is its powerful cooling capacity, which enables it to quickly lower indoor temperatures, making it ideal for larger spaces or warmer climates. With a cooling capacity of 18000 BTU, this model ensures that even during the hottest summer days, users can enjoy a refreshing indoor atmosphere. The unit operates quietly, allowing for peaceful relaxation or focused work without the disturbance of loud compressor noises.

The KC18AGH model is equipped with advanced inverter technology that adjusts the compressor speed according to the cooling demand. This feature not only enhances energy efficiency but also helps to maintain a consistent temperature throughout the space. The inverter technology significantly reduces electricity consumption compared to non-inverter models, making it an environmentally friendly choice.

Both models come with a range of convenient features, including multiple cooling and fan speed options, sleep mode, and a programmable timer. The sleep mode function gradually increases the temperature at night, ensuring a comfortable sleep environment while saving energy. The programmable timer allows users to set the air conditioning unit to operate only when needed, further optimizing energy use.

Additionally, the Haier SAP-K18AM and KC18AGH are designed with user comfort in mind. They come with an easy-to-use remote control, allowing for effortless adjustments from across the room. The units also include a self-cleaning feature that helps reduce mold and bacteria buildup, ensuring that the air quality remains high.

In conclusion, the Haier SAP-K18AM and KC18AGH air conditioners represent cutting-edge technology and design. With powerful cooling capabilities, energy-efficient inverter technology, and a suite of user-friendly features, these models are ideal for anyone looking to improve the comfort and quality of their indoor environment. Whether for residential or commercial use, Haier continues to set the standard in reliable and effective air conditioning solutions.