Haier KC18AGH, SAP-K18AM How to Install Batteries, Using the Remote Control Unit Fig

Page 17

Operation and Maintenance

4. OPERATION OF WIRELESS REMOTE CONTROL UNIT

4.7How to Install Batteries

1.Slightly to press the place with , along the arrowhead direction to push the back cover of wireless remote control. (Fig. 1)

2.Take out the old batteries. (Fig. 1)

3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity. (Fig. 2)

4.Attach the back cover. (Fig. 2, procedure 4)

NOTE

The batteries last about six months, depending on how much you use the remote control unit. Replace the batteries when the remote control unit’s display fails to light, or when the remote control cannot be used to change the air conditioner’s settings.

When changing the batteries, do not use the old or different batteries, Use two fresh leak-proof type -AAA alkaline batteries, otherwise, it can cause the malfunction of the wireless remote control.

If the wireless remote control will not be used for more than one month, please take them out, and don't let the leakage liquid damage the wireless remote control.

It should be placed at where is 1m away from the TV set or stereo sound sets. If the wireless remote control can not operate normally, please take them out, after 30s later and reinsert, if they can’t normally run, please change them.

The remote control signal can be received at a distance of up to about 4meter.

4.8 Using the Remote Control Unit (Fig. 3)

When using the remote control unit, always point the unit’s transmitter head directly at the air conditioner’s receiver.

4.9 Emergency Operation (Fig. 4)

If the wireless remote control is lost or broken, please use the manual switch button. At this time, the unit will run at the “AUTO” mode, but the temperature and fan speed cannot be changed.

To open the panel, the manual switch is located on the displayer box. The operation was shown as below:

Turn ON the Unit: At unit turned off, press the button, the unit will run at Auto mode immediately. The microcomputer will accord to the indoor

temperature to select (Cooling, Heating or Fan) and obtain the comfortable effect.

Turn OFF the Unit: At unit turned on, press the button, the unit will stop working.

2

1

Fig. 1

3

4

Sketch map for changing batteries

Fig. 2

(Indoor unit) Air conditioner

 

 

Receiver

 

C

(Transmitter head)

ON/OFF

SWING

 

-

 

 

F

AN

T-

ON

-

Remote control unit

Fig. 3

o

Manual switch

Fig. 4

15

Image 17
Contents 85S-6-4181-002-00-0 Split System Air Conditioner Contents Operation and Maintenance Operation and Maintenance Heat Pump Model Only Conditions of Unit Cant Operate Normally Working Temperature RangeIndoor Unit Names and Fuctions of Each PartRemote Control Unit Display Operation of Wireless Remote Control UnitRemote Control Unit Functions How it Works? AutoStep Using the General OperationTimer OFF mode Example Using the 24-Hour on or OFF TimerSetting procedure Heating Mode Using the Sleep OperationCooling and DRY Mode Sleep Mode is used for saving energy Setting OFF the displayer indicator light Using of the Special Features & RemarksDRY Operation How it works? Auto Operation How it works? Blow OperationSwing Operation How it works? Emergency Operation Fig How to Install BatteriesUsing the Remote Control Unit Fig Clean the Front Panel Clean and CareTake off the front panel WashingCleaning Cleaning the Air FiltersCheck Before You Use Maintain After UsePhenomenon TroubleshootingPhenomenon Troubleshooting Troubleshooting Outdoor Unit Installation Position Selection Basic Requirements for Installation PositionIndoor Unit Installation Position Selection Wrong connection, may cause fire Safety Requirements for Electric AppliancesEarthing Requirements Others Space to the ceiling Installation Diension DiagramSpace to the wall Space to the obstructionInstall the Real Panel Install Indoor UnitInstall the Piping Hole Install the Water Drainage PipeWiring Instructions Connect Indoor and Outdoor Electric WireWiring System Diagram Wire Length and DiameterHow to Install the Indoor Unit Wiring Instructions for the Outdoor Unit Install Outdoor UnitRefrigerant Tubing Flaring Procedure With a Flare ToolUse of The Flaring Method DeburringFinish the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing Taping the TubesAIR Purging with a Vacuum Pump for Test RUN Air PurgingAir Purging Tubing Length AccessoriesHow to install Pump Down What is Pump Down?Pump Down Procedure Test Operation Check After Installation and Test RUNCheck After Installation

KC18AGH, SAP-K18AM specifications

The Haier SAP-K18AM and KC18AGH are part of Haier's innovative line of air conditioning solutions designed to provide efficient cooling and exceptional comfort in various environments. These models stand out for their blend of modern technology, user-friendly features, and energy efficiency.

One of the main features of the Haier SAP-K18AM is its powerful cooling capacity, which enables it to quickly lower indoor temperatures, making it ideal for larger spaces or warmer climates. With a cooling capacity of 18000 BTU, this model ensures that even during the hottest summer days, users can enjoy a refreshing indoor atmosphere. The unit operates quietly, allowing for peaceful relaxation or focused work without the disturbance of loud compressor noises.

The KC18AGH model is equipped with advanced inverter technology that adjusts the compressor speed according to the cooling demand. This feature not only enhances energy efficiency but also helps to maintain a consistent temperature throughout the space. The inverter technology significantly reduces electricity consumption compared to non-inverter models, making it an environmentally friendly choice.

Both models come with a range of convenient features, including multiple cooling and fan speed options, sleep mode, and a programmable timer. The sleep mode function gradually increases the temperature at night, ensuring a comfortable sleep environment while saving energy. The programmable timer allows users to set the air conditioning unit to operate only when needed, further optimizing energy use.

Additionally, the Haier SAP-K18AM and KC18AGH are designed with user comfort in mind. They come with an easy-to-use remote control, allowing for effortless adjustments from across the room. The units also include a self-cleaning feature that helps reduce mold and bacteria buildup, ensuring that the air quality remains high.

In conclusion, the Haier SAP-K18AM and KC18AGH air conditioners represent cutting-edge technology and design. With powerful cooling capabilities, energy-efficient inverter technology, and a suite of user-friendly features, these models are ideal for anyone looking to improve the comfort and quality of their indoor environment. Whether for residential or commercial use, Haier continues to set the standard in reliable and effective air conditioning solutions.