6. TROUBLESHOOTING

CAUTION

Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money.

Phenomenon

Troubleshooting

Dot not operate immediately when the air

Once the air conditioner be restarted

conditioner is restarted.

immediately after turned off, overload

Waiting

protect switch would make it will run after a 3

 

 

delay of minutes.

There's unusual smell blowing from the outlet

The unit has no peculiar smell by itself. If

after operation is started.

happened, this is the smell accumulated in the

 

ambient.

Solution : Clean the air filters (see Pg.16). If the problem still has, the unit required servicing. Hence, please contact with SANYO authorized maintenance center.

Sound of water flow can be heard during

Sometimes there is swoosh, or gurgle while

operation.

the air conditioner is started, stopped or when

 

the compressor started or stopped running,

 

the sound is due to refrigerant flowing. They

 

are not malfunctions.

The mist is emitted.

When indoor temp. and humidity are higher,

 

sometimes this phenomenon will happen.

 

This is caused by the room air is swiftly cooled

 

down. After run for a while, indoor temp. and

 

humidity will fall down, the mist will die away.

Creaking noise can be heard when start or stop the unit.

This is caused by the deformation of plastic due to the change of temperature.

18

Image 20
Contents 85S-6-4181-002-00-0 Split System Air Conditioner Contents Operation and Maintenance Operation and Maintenance Heat Pump Model Only Working Temperature Range Conditions of Unit Cant Operate NormallyNames and Fuctions of Each Part Indoor UnitOperation of Wireless Remote Control Unit Remote Control Unit DisplayRemote Control Unit Functions Auto How it Works?Using the General Operation StepTimer OFF mode Example Using the 24-Hour on or OFF TimerSetting procedure Heating Mode Using the Sleep OperationCooling and DRY Mode Sleep Mode is used for saving energy Using of the Special Features & Remarks Setting OFF the displayer indicator lightDRY Operation How it works? Auto Operation How it works? Blow OperationSwing Operation How it works? Emergency Operation Fig How to Install BatteriesUsing the Remote Control Unit Fig Clean and Care Clean the Front PanelTake off the front panel WashingCleaning the Air Filters CleaningCheck Before You Use Maintain After UseTroubleshooting PhenomenonPhenomenon Troubleshooting Troubleshooting Outdoor Unit Installation Position Selection Basic Requirements for Installation PositionIndoor Unit Installation Position Selection Wrong connection, may cause fire Safety Requirements for Electric AppliancesEarthing Requirements Others Installation Diension Diagram Space to the ceilingSpace to the wall Space to the obstructionInstall Indoor Unit Install the Real PanelInstall the Piping Hole Install the Water Drainage PipeConnect Indoor and Outdoor Electric Wire Wiring InstructionsWire Length and Diameter Wiring System DiagramHow to Install the Indoor Unit Install Outdoor Unit Wiring Instructions for the Outdoor UnitFlaring Procedure With a Flare Tool Refrigerant TubingUse of The Flaring Method DeburringConnecting Tubing between Indoor and Outdoor Units Finish the InstallationInsulation of Refrigerant Tubing Taping the TubesAir Purging AIR Purging with a Vacuum Pump for Test RUNAir Purging Tubing Length AccessoriesHow to install Pump Down What is Pump Down?Pump Down Procedure Test Operation Check After Installation and Test RUNCheck After Installation

KC18AGH, SAP-K18AM specifications

The Haier SAP-K18AM and KC18AGH are part of Haier's innovative line of air conditioning solutions designed to provide efficient cooling and exceptional comfort in various environments. These models stand out for their blend of modern technology, user-friendly features, and energy efficiency.

One of the main features of the Haier SAP-K18AM is its powerful cooling capacity, which enables it to quickly lower indoor temperatures, making it ideal for larger spaces or warmer climates. With a cooling capacity of 18000 BTU, this model ensures that even during the hottest summer days, users can enjoy a refreshing indoor atmosphere. The unit operates quietly, allowing for peaceful relaxation or focused work without the disturbance of loud compressor noises.

The KC18AGH model is equipped with advanced inverter technology that adjusts the compressor speed according to the cooling demand. This feature not only enhances energy efficiency but also helps to maintain a consistent temperature throughout the space. The inverter technology significantly reduces electricity consumption compared to non-inverter models, making it an environmentally friendly choice.

Both models come with a range of convenient features, including multiple cooling and fan speed options, sleep mode, and a programmable timer. The sleep mode function gradually increases the temperature at night, ensuring a comfortable sleep environment while saving energy. The programmable timer allows users to set the air conditioning unit to operate only when needed, further optimizing energy use.

Additionally, the Haier SAP-K18AM and KC18AGH are designed with user comfort in mind. They come with an easy-to-use remote control, allowing for effortless adjustments from across the room. The units also include a self-cleaning feature that helps reduce mold and bacteria buildup, ensuring that the air quality remains high.

In conclusion, the Haier SAP-K18AM and KC18AGH air conditioners represent cutting-edge technology and design. With powerful cooling capabilities, energy-efficient inverter technology, and a suite of user-friendly features, these models are ideal for anyone looking to improve the comfort and quality of their indoor environment. Whether for residential or commercial use, Haier continues to set the standard in reliable and effective air conditioning solutions.