TA-500

Voltage Setting

Your models will be set up at the factory for correct operation on your local voltage supply. No further adjustment is necessary.

Voltage Range

The minimum supply voltage over which the amplifier will operate is 180V for the 220-240V range, and 90V for the 110-120V range. Naturally, maximum power output will be reduced accordingly from the published ratings.

The maximum supply voltage which exceeds safe limits and causes the amplifiers to switch- off is in excess of 260 V for 220/240 V range, and 130 V for the 108/120 V range. This is however dependent on load impedance and program drive level as mentioned above.

Obviously, the mains voltage will reach these limits only in exceptional circumstances and the A/P (Audio Protect) LED will then flash.

Audio Connections & Controls

The amplifiers’ actively balanced, fully-floating input connections are fuss-free, regardless of the installation's complexity.

The incoming 3-pin XLR plug should be connected, with a high grade twin-core sreened cable, as follows.

Pin 1

Screen - connect to shield

Pin 2

hot (signal +)

Pin 3

cold (signal -)

The shield connection to pin 1 at each amplifier input must be maintained under all circumstances, as TURBOSOUND will not be responsible for consequential damage arising to loudspeakers, etc., should this connection not be made.

The amplifiers are designed to operate with fully balanced equipment. Ground loops or loss

TA-500 user manual

Page 65

Image 65
Contents Aspect TA-500 Systems TA-500 TA-500 TA-500 Audio Connections & Controls TA-500HDP EC Declaration of ConformityTurbosound Aspect System Concepts IntroductionAspect Polyhorn Concept TA-880 TA-500 Narrow 25º horizontal coverage Network Capability Loudspeaker Management System LMS ConceptLMS-D2X Loudspeaker Management Systems Self-powered Loudspeakers Power AmplifiersDigital Controllers Aspect Loudspeaker ComponentsTA-500 TA-500tDP Self-powered Touring Three-way Loudspeaker TA-500DP Self-powered Three-way LoudspeakerTA-500 Three-way Loudspeaker TA-500t Touring Three-way LoudspeakerTA-500H Horizontal Three-way Loudspeaker TA-500HDP Self-powered Horizontal Three-way LoudspeakerTA-500HM Two-way High/Mid Loudspeaker TSW-218 SubwooferB18 Subwoofer B18DP Self-powered SubwooferTransportation Overview Flying and StackingSafety Notes on Rigging Secondary Safeties Safety InspectionsTA-500 Sample Certificate of Load Test Aspect TA-500 Flying Systems Flying HardwareHorizontal Coverage Vertical CoverageTouring two-wide flybar Flybar SettingsTA-500T Touring Flying System TOP View FC-500T Flying Chains Flying MatrixTA-500 Integral Flying Hardware TS-890 Tilting StrapsCaptive Biscuit BoltLocking Mechanism Connecting Flying Chains to the CabinetSliding the top chain profile into the slot Assembly of the Top Chains to the CabinetAdding additional rows Connection of additional rowsAttaching the biscuit Setting the angles between rowsBiscuit slides into lower cabinet Attaching the Tilt StrapsFront view of the assembled cluster Lifting the columnTA-500 TA-500 Install Flying System Rigging Instructions TA-500 TA-500 Array is now ready to pick up Flying a single TA-500 cabinet using M10 eyebolts LMS Series Loudspeaker Management Systems Mechanical InstallationIntroduction UnpackingLMS-D24 and D26 Loudspeaker Management Systems FeaturesLCD Front Panel FunctionsTA-500 Rear Panel Functions Creating a Crossover Selecting a Factory PresetOperating the LMS-D24 and D26 Starting up Navigation and Viewing Parameters EQ1 100Hz 0dBNavigation Out1 Freq Width Gain EQ1 100Hz 1.4Q 0.0dBPreset Recall PresetsStore My System Preset StoreStereo / Mono Formats DSP Processing Layout Input DSP block diagramOutput DSP block diagram DSP processing Input Channels A Delay 1.50msA Freq Shape Parametric filters Parametric EqualisationHigh and Low shelving filters Output Channels Gain and Polarity DelayHigh and Low Pass Filters Out1 Freq Shape LPF 2.50k LR24Out1 Freq Slope Gain EQ- 100Hz 12dB 0.0dB Routing LimitersUtilities Utility functions General Features & Facilities T-45 High Efficiency Audio Power AmplifiersFront Panel Functions T-25 Front Panel Functions T-45 Safety Earthing Mains PowerPowering Up Audio Connections & Controls Voltage SettingVoltage Range Input Impedance Gain and Sensitivity SettingsPolarity Damping Factor Attenuation & Gain SettingOutput Connections Cooling System Long Speaker LinesTA-500 TA-500t TA-500H TA-500HM Appendix a Technical SpecificationsTA-500DP TA-500tDP TA-500HDP Stock Code Model Description Appendix B Spare Parts ListAppendix C Warranty TA-500