Turbosound TA-500TDP, TA-500HDP Polarity, Input Impedance, Gain and Sensitivity Settings

Page 66

user manual

TA-500

of performance may be experienced if connected to unbalanced sources. If it is unavoidable, however, the following wiring convention should be used.

Pin 1

Screen - connect to chassis of the unbalanced equipment,

 

or left disconnected at the unbalanced end

Pin 2

signal hot

Pin 3

Signal cold

Polarity

In accordance with international standards, T series amplifiers are supplied with Pin 2 hot (+), so a positive (+V) input gives a positive (+V) output from the positive (+) output terminals.

Input Impedance

Each amplifier channel has an input impedance of 10k, seen between pins 2 & 3 of the XLR.

When used with the LMS-D6 Loudspeaker Management System, distribution amplifiers are not required when a large number of T-25 or T-45 amplifier inputs are driven in parallel.

Gain and Sensitivity Settings

Gain settings are changed internally by simple jumper links. Two rows of pins marked - GAIN A and GAIN B - are situated on the input PCB (PCB701). A jumper link sets the gain and the settings are as follows:

Link 1 & 2

Gives 32dB gain

Link 3 & 4

Gives 26dB gain

Link 2 & 3

Gives approx 37.5dB gain

NOTE: Factory setting is normally link 1 & 2 = 32dB gain.

TA-500 user manual

Page 66

Image 66
Contents Aspect TA-500 Systems TA-500 TA-500 TA-500 Audio Connections & Controls EC Declaration of Conformity TA-500HDPIntroduction Turbosound Aspect System ConceptsAspect Polyhorn Concept TA-880 TA-500 Narrow 25º horizontal coverage Loudspeaker Management System LMS Concept LMS-D2X Loudspeaker Management SystemsNetwork Capability Digital Controllers Power AmplifiersSelf-powered Loudspeakers Aspect Loudspeaker ComponentsTA-500 TA-500 Three-way Loudspeaker TA-500DP Self-powered Three-way LoudspeakerTA-500tDP Self-powered Touring Three-way Loudspeaker TA-500t Touring Three-way LoudspeakerTA-500HM Two-way High/Mid Loudspeaker TA-500HDP Self-powered Horizontal Three-way LoudspeakerTA-500H Horizontal Three-way Loudspeaker TSW-218 SubwooferB18DP Self-powered Subwoofer B18 SubwooferTransportation Flying and Stacking OverviewSafety Notes on Rigging Safety Inspections Secondary SafetiesTA-500 Sample Certificate of Load Test Horizontal Coverage Flying HardwareAspect TA-500 Flying Systems Vertical CoverageFlybar Settings TA-500T Touring Flying SystemTouring two-wide flybar TOP View Flying Matrix FC-500T Flying ChainsTA-500 TS-890 Tilting Straps Integral Flying HardwareBolt Captive BiscuitConnecting Flying Chains to the Cabinet Locking MechanismAssembly of the Top Chains to the Cabinet Sliding the top chain profile into the slotConnection of additional rows Adding additional rowsSetting the angles between rows Attaching the biscuitAttaching the Tilt Straps Biscuit slides into lower cabinetLifting the column Front view of the assembled clusterTA-500 TA-500 Install Flying System Rigging Instructions TA-500 TA-500 Array is now ready to pick up Flying a single TA-500 cabinet using M10 eyebolts Introduction Mechanical InstallationLMS Series Loudspeaker Management Systems UnpackingFeatures LMS-D24 and D26 Loudspeaker Management SystemsFront Panel Functions LCDTA-500 Rear Panel Functions Selecting a Factory Preset Operating the LMS-D24 and D26 Starting upCreating a Crossover EQ1 100Hz 0dB Navigation and Viewing ParametersOut1 Freq Width Gain EQ1 100Hz 1.4Q 0.0dB NavigationPresets Preset RecallPreset Store Store My SystemDSP Processing Layout Input DSP block diagram Output DSP block diagramStereo / Mono Formats A Delay 1.50ms DSP processing Input ChannelsA Freq Shape Parametric Equalisation High and Low shelving filtersParametric filters Delay Output Channels Gain and PolarityOut1 Freq Shape LPF 2.50k LR24 High and Low Pass FiltersOut1 Freq Slope Gain EQ- 100Hz 12dB 0.0dB Limiters RoutingUtilities Utility functions T-45 High Efficiency Audio Power Amplifiers General Features & FacilitiesFront Panel Functions T-25 Front Panel Functions T-45 Mains Power Powering UpSafety Earthing Voltage Setting Voltage RangeAudio Connections & Controls Gain and Sensitivity Settings PolarityInput Impedance Attenuation & Gain Setting Output ConnectionsDamping Factor Long Speaker Lines Cooling SystemAppendix a Technical Specifications TA-500 TA-500t TA-500H TA-500HMTA-500DP TA-500tDP TA-500HDP Appendix B Spare Parts List Stock Code Model DescriptionAppendix C Warranty TA-500
Related manuals