user manual
TA-890
Parametric Equalisation
Eight sections of equalisation are provided, two shelving filters and six fully variable parametric sections.
High and Low shelving filters
|
| |
In A Freq | Slope | Gain |
EQ1 100Hz | 12dB | 0.0dB |
a | b | c |
|
|
|
a | b | c |
Knob A: Frequency, 10.0Hz to 25.6kHz in variable steps
Knob B: Slope, 6 to 12dB / octave in 1dB steps
Knob C: Gain,
The frequency is specified as point where the filter deviates by 3dB from the gain value.
Parametric filters
|
| |
In A Freq | Width | Gain |
EQ1 100Hz | 1.4Q | 0.0dB |
a | b | c |
|
|
|
a | b | c |
Knob A, Centre Frequency, 10.0Hz to 25.6kHz in variable steps
Knob B, Width, display selectable, Q or BW (Bandwidth)
BW adjustable from 0.05 to 5 octaves in variable steps
Q adjustable from 14.2 to 0.2 in variable steps
Knob C, Gain,
Page 64