Installation
Air Line and Accessories
NOTE: Install the air line accessories in the order shown in the Typical Installation on page 7.
NOTICE
Do not hang the air accessories directly on the air inlet. Mount them on brackets. Always use a flexible hose between all connections. The air inlet is not strong enough to support accessories and may cause one or more to break.
•Use thread sealant on all male threads except swivel connections.
•Install a pump runaway valve (D) to shut off the air to the pump if the pump accelerates beyond the
•Install the air regulator (G) to control pump speed and pressure.
For NPT models order Graco Part No. 24H420 or for BSP models order Graco Part No. 24H419.
•Install a
For NPT models order Graco Part No. 110223 or for BSP models order Graco Part No. 125272.
•On the main air supply line from the compressor, install an air line filter (H) to remove harmful dirt and contaminants from the compressor air supply.
Follow Plate - Grease Models Only
For grease models only a follow plate is required for pumping fluid from the drum. See page 12 for follow plate installation instructions.
3A1334E | 9 |