Graco 3A1334E Installation Guidelines, Stationary Mounting Layout, Pump Mounting

Page 8

Installation

Installation Guidelines

Reference letters found in the following instructions, refer to Typical Installation diagram provided on page 7.

A ball valve must be installed upstream of the regu- lator (G).

The fluid outlet line (A), fluid inlet line (L) and air inlet line (M) must be flexible (such as a hose).

NOTE: To prevent damage to the pump, remove sedi- ment from the bottom of the container before installing a pump on an existing container.

The maximum working pressure of each pump in your system may not be the same. To reduce the risk of over-pressurizing any part of your system, which may result in component rupture, fire or explosion and cause serious bodily injury, be sure you know the maximum working pressure rating of each pump and its connected components.

Never exceed the maximum working pressure of the lowest rated component connected to a partic- ular pump.

Be sure you know the maximum working pressure of each component.

Do not exceed the maximum pump cycle rate.

Regulate air pressure to prevent over pressuriza- tion at fluid section of the pump.

Regulate air pressure to the pump so that no fluid line component or accessory is over pressurized.

Stationary Mounting Layout

Plan the layout for easy operator access to the pump air controls, sufficient room to change drums and a secure platform.

Pump Mounting

1.Install bung adapter (K) into bung mount/bracket/or drum cover.

2.Install pump (B) into bung adapter (K).

B

A

K

aa

FIG. 3

Installing Outlet Hose (FIG. 3)

1.Connect the swivel adapter (aa) to the pump fluid outlet. Tighten securely and torque as recom- mended below:

For NPT models: 1 to 1-1/2 turns past hand tight.

For BSPT models: 1-1/2 to 2 turns past hand tight.

2.Connect the fluid hose (A) to the swivel adapter (aa).

3.Connect a suitable dispensing valve or extra hose to the 6-ft hose.

8

3A1334E

Image 8
Contents Manual Number Language Important Safety InstructionsRelated Translated Manuals Oil Pump Models PumpsGrease Pump Models Skin Injection Hazard Equipment Misuse Hazard Installation GroundingKey FIG Typical InstallationStationary Mountings Installation Guidelines Installing Outlet Hose FIGStationary Mounting Layout Pump MountingAir Line and Accessories Follow Plate Grease Models OnlyThermal Relief Theory of Operation OperationThermal Induced Pressure Relief Oil pumps only Start-up Pressure Relief ProcedureDetermining Output Pressure Using the Air Regulator Is for Oil Pumps Only Relieve pressure,Operation Repair Replacing Pilot ValvesParts Description QtyKit No Description Qty Throat and Piston Seal Replacement Kit 24H853 FIGRelated Oil Pump Kits Kits 21 20Grease Pump Models 24G600 24G608 MUFFLER, 3/8Related Grease Pump Kits Throat and Piston Seal Replacement Kit 24H854 FIGRing and Seal Replacement Kit 24H856 FIG Kits, Oil or Grease Pump Air Valve Repair and Replacement Kits Replace Seals or Rebuild Air Valve KitsAir Valve Seal Kit 24H851 Air Valve Repair Kit 24H798Pilot Valve Replacement Kit 24H749 Oil Models TroubleshootingProblem Cause Solution Replace gasket Grease Models Relieve pressureTechnical Data 31 or 51 Oil ModelsDimensions Performance Curve Oil ModelsGrease Models Performance Curve Tested with ISO 46 Hyd OilDimensions 3A1334E Graco Standard Warranty Graco Information